Nestor Luis Guerrero

Dr. Nestor Luis Guerrero


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2020 in Metals
Verified
Journal Article
Open access
PDF file
ENEduardo Nuñez
Eduardo Nuñez
NBNwar Boainy
Nwar Boainy
Freddy GonzalezFreddy Gonzalez
Freddy Gonzalez
RTRonald Torres
Ronald Torres
Ricardo PicónRicardo Picón
Ricardo Picón
NGNestor Luis Guerrero
Nestor Luis Guerrero
Steel buildings with tubular columns showed a satisfactory performance during the Honshu (2011) earthquake, unlike steel buildings in the 1994 Northridge and 1995 Kobe earthquakes, where welded moment connections showed damage in their joints. In this research, a lateral joint using a hollow structural section (HSS)-beam and HSS-column subjected to cyclic displacement was performed. Three large-scale specimens were tested and a numerical model was calibrated, reaching a good adjustment. Later, several configurations of beams and columns were evaluated using finite element (FE) models from the numerical model previously calibrated. A flexural resistance higher 0.80 Mp at 0.04 [rad] was obtained for all cases studied. The ductility factor in the 3 specimens was lower than 2.5, therefore a non-ductile behavior was controlled in the connection. This aspect is very important although a 0.8 Mp at 0.04 [rad] was achieved. Finally, the typical welded moment connection can be improved using the bolted moment connection, which allows the concentration of inelastic incursion in the beam compared with the welded solution. However, a non-ductile behavior derived from local buckling in flanges of a tubular beam can affect the seismic performance.

26 February 2024 in Journal of Building Engineering
Verified
Journal Article
Open access
NGNestor Luis Guerrero
Nestor Luis Guerrero
JCJulian Carrillo
Julian Carrillo
RHReyes I. Herrera
Reyes I. Herrera
MMMaríae. Marante
Maríae. Marante

31 October 2022 in Buildings
Verified
Journal Article
Open access
PDF file
ENEduardo Nuñez
Eduardo Nuñez
Ramon Mata LemusRamon Mata Lemus
Ramon Mata Lemus
JCJorge Maximiliano Castro
Jorge Maximiliano Castro
Nelson MaureiraNelson Maureira
Nelson Maureira
NGNestor Luis Guerrero
Nestor Luis Guerrero
ARangel Roco
angel Roco
In this research, the influence of global slenderness and sliding pallets factor on the seismic design of steel storage racks are assessed. Variations in span length, the height of storage levels, live load, and percentage of live load considered in the seismic mass are studied for different levels of seismic zone and soil type. The models were designed according to the Chilean Code NCh2369. Subsequently, a global sensitivity analysis was developed to analyze the influence of each studied parameter in the seismic design response in terms of fundamental period, drift, and base shear from a response spectral analysis approach. A total of 12000 simulations were performed. Two-hundred additional models were performed to evaluate the variation of seismic mass in the structural response. Results indicate a significant influence of live loads and seismic mass on steel racks designed for soft soils and unbrace conditions. The stiffness also modifies the performance of the racks, mainly in models using braces in the down-aisle direction and cross-aisle direction. In these cases, the seismic mass factor does not have a strong influence on structural response in comparison to the global slenderness.

24 March 2025 in International Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
JCJulian Carrillo
Julian Carrillo
NGNestor Luis Guerrero
Nestor Luis Guerrero
CPCarlos Piscal
Carlos Piscal
Correlations between fiber characteristics and the compressive, flexural-tensile, and shear strengths of steel fiber reinforced concrete (SFRC) are proposed in the literature to facilitate the code-compliant design. In this study, the correlation between flexural-tensile and direct shear stresses on plain concrete (PC) and SFRC beams and columns is evaluated. The database included 1767 data from direct shear tests of beam and column, and from four-point bending tests (4PBT) of PC and SFRC beams. Data comprised measured results from this study and from the results of other research programs published in the literature. The main characteristics of the database were fiber aspect ratios (l f /d f between 65 and 80), fiber volume fraction (V f between 0.25% and 2%), and compressive strength of concrete (f′ c between 28 and 78 MPa). From the trends observed in the experimental results, an empirical equation is proposed to estimate the direct shear and flexural-tensile performance of SFRC. The results of the statistical analysis showed that the equation is a suitable tool to estimate the maximum direct shear and flexural-tensile strengths of SFRC. The correlation between shear and flexural-tensile strengths would facilitate SFRC code-compliant design.