Marcos Lema

Prof. Marcos Lema

University of A Coruña
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Anne Marie Elisabeth GossetAnne Marie Elisabeth Gosset
Anne Marie Elisabeth Gosset
DBDavid Barreiro-Villaverde
David Barreiro-Villaverde
JPJuan Carlos Becerra Permuy
Juan Carlos Becerra Permuy
Marcos LemaMarcos Lema
Marcos Lema
AAAna Ares-Pernas
Ana Ares-Pernas
MLMaria José Abad López
Maria José Abad López
In the last decade, Fused Deposition Modeling (FDM) has gained popularity for allowing the fabrication of pieces with complex shapes. The final quality of the pieces is strongly linked to the shape, size and surface finish of the strands deposited successively, which themselves depend on the printing parameters and extruded material properties. In this work, we present an experimental characterization of an extruded and deposited single strand of Poly-Lactic Acid (PLA), by means of high-speed visualization of the bead region between the substrate and the nozzle, where the molten polymer is still in liquid phase. A Computational Fluid Dynamics (CFD) model proposed in literature, and, based on isothermal and viscous flow assumptions, is validated with this data in terms of strand height and meniscus shape. The characteristics of the printed layer are also confronted to the measurements of the solidified strands by microscopy, with a good agreement. The focus on high printing speeds allows extending the conclusions of previous studies. Regarding the surface finish, the roughness patterns detected on the printed strands are correlated to the velocity fluctuations of the printing head. The CFD model does not capture those thickness variations, however, due to not accounting for solidification.

1 January 2014 in Journal of Propulsion and Power
Verified
Journal Article
Closed access
JPJ. Pinho
J. Pinho
Marcos LemaMarcos Lema
Marcos Lema
PRP. Rambaud
P. Rambaud
JSJ. Steelant
J. Steelant

1 May 2009 in Journal of Propulsion and Power
Verified
Journal Article
Closed access
JAJ. Anthoine
J. Anthoine
Marcos LemaMarcos Lema
Marcos Lema

1 March 2014 in Journal of Propulsion and Power
Verified
Journal Article
Closed access
PPP. Porca
P. Porca
Marcos LemaMarcos Lema
Marcos Lema
PRP. Rambaud
P. Rambaud
JSJ. Steelant
J. Steelant
The aim of this work is to study the fluid hammer and related multiphase phenomena taking place in a confined environment, where pressurized liquid faces vacuum conditions after opening an isolation valve. This paper describes the experimental facility built for this purpose, the tests performed, and shows the comparison with the numerical results obtained with a transient one-dimensional software based upon conservation equations. Because the multiphase phenomena taking place in the liquid front moving along the pipe are complex and difficult to interpret, a graphical tool by means of X-t diagrams was adapted by the authors to characterize the physical phenomena involved. Contrary to the classical water hammer analysis published in the literature so far, the X-t diagrams allow a simultaneous study in time and space for each of the magnitudes involved in the evolution of the fluid hammer.

1 December 2016 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
Marcos LemaMarcos Lema
Marcos Lema
FPFernando López Peña
Fernando López Peña
JBJean-Marie Buchlin
Jean-Marie Buchlin
PRPatrick Rambaud
Patrick Rambaud
JSJohan Steelant
Johan Steelant

29 November 2010 in Sensors
Verified
Journal Article
Open access
PDF file
FPFernando López Peña
Fernando López Peña
ADAlvaro Deibe Diaz
Alvaro Deibe Diaz
Marcos LemaMarcos Lema
Marcos Lema
SVSantiago Vazquez-Rodriguez
Santiago Vazquez-Rodriguez
After studying the performance and characteristics of actual laminar flowmeters a new disposition for this type of sensors is proposed in such a way that the measurement errors introduced by the intrinsic nature of the device can be minimized. The preliminary study shows that the developing entry region introduces non-linearity effects in all these devices. These effects bring about not only errors, but also a change in the slope of the linear calibration respect of the Poiseuille relation. After a subsequent analysis on how these non-linearity errors can be reduced, a new disposition of this type of flowmeters is introduced. This device makes used of flow elements having pressure taps at three locations along its length and connected to three isolated chambers. In this way, the static pressure can be measured at three locations and contributed to by the pressure taps at the level of each chamber. Thus the linearization error is reduced with an additional advantage of producing a reduced pressure drop.