Philip Hartjen

Dr. Philip Hartjen

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Ole JungOle Jung
Ole Jung
Ralf SmeetsRalf Smeets
Ralf Smeets
PHPhilip Hartjen
Philip Hartjen
RSReinhard Schnettler
Reinhard Schnettler
FFFrank Feyerabend
Frank Feyerabend
AKAlexander Kopp
Alexander Kopp
Magnesium (Mg)-based biomaterials are promising candidates for bone and tissue regeneration. Alloying and surface modifications provide effective strategies for optimizing and tailoring their degradation kinetics. Nevertheless, biocompatibility analyses of Mg-based materials are challenging due to its special degradation mechanism with continuous hydrogen release. In this context, the hydrogen release and the related (micro-) milieu conditions pretend to strictly follow in vitro standards based on ISO 10993-5/-12. Thus, special adaptions for the testing of Mg materials are necessary, which have been described in a previous study from our group. Based on these adaptions, further developments of a test procedure allowing rapid and effective in vitro cytocompatibility analyses of Mg-based materials based on ISO 10993-5/-12 are necessary. The following study introduces a new two-step test scheme for rapid and effective testing of Mg. Specimens with different surface characteristics were produced by means of plasma electrolytic oxidation (PEO) using silicate-based and phosphate-based electrolytes. The test samples were evaluated for corrosion behavior, cytocompatibility and their mechanical and osteogenic properties. Thereby, two PEO ceramics could be identified for further in vivo evaluations.

Verified
Journal Article
Open access
PDF file
LGLinna Guo
Linna Guo
Ralf SmeetsRalf Smeets
Ralf Smeets
LKLan Kluwe
Lan Kluwe
PHPhilip Hartjen
Philip Hartjen
Mike BarbeckMike Barbeck
Mike Barbeck
Anders HenningsenAnders Henningsen
Anders Henningsen
A number of modifications have been developed in order to enhance surface cytocompatibility for prosthetic support of dental implants. Among them, ultraviolet (UV) light and non-thermal plasma (NTP) treatment are promising methods. The objective of this study was to compare the effects of UV light and NTP on machined titanium, zirconia and modified polyetheretherketone (PEEK, BioHPP) surfaces in vitro. Machined samples of titanium, zirconia and BioHPP were treated by UV light and NTP of argon or oxygen for 12 min each. Non-treated disks were set as controls. A mouse fibroblast and a human gingival fibroblast cell line were used for in vitro experiments. After 2, 24 and 48 h of incubation, the attachment, viability and cytotoxicity of cells on surfaces were assessed. Results: Titanium, zirconia and BioHPP surfaces treated by UV light and oxygen plasma were more favorable to the early attachment of soft-tissue cells than non-treated surfaces, and the number of cells on those treated surfaces was significantly increased after 2, 24 and 48 h of incubation (p < 0.05). However, the effects of argon plasma treatment on the cytocompatibility of soft tissue cells varied with the type of cells and the treated material. UV light and oxygen plasma treatments may improve the attachment of fibroblast cells on machined titanium, zirconia and PEEK surfaces, that are materials for prosthetic support of dental implants.

22 July 2020 in Cells
Verified
Journal Article
Open access
PDF file
PAParimah Ahmadi
Parimah Ahmadi
PHPhilip Hartjen
Philip Hartjen
MKMatin Kohsar
Matin Kohsar
SKSilke Kummer
Silke Kummer
SSStefan Schmiedel
Stefan Schmiedel
JWJulian Schulze zur Wiesch
Julian Schulze zur Wiesch
The ectonucleotidases CD39 and CD73 regulate immune responses by balancing extracellular ATP and adenosine in inflammation and are likely to be involved in the pathophysiology of COVID-19. Here, we analyzed CD39 and CD73 on different lymphocyte populations in a small cohort of COVID-19 patients and in healthy individuals. We describe a significantly lower level of expression of CD73 on cytotoxic lymphocyte populations, including CD8+ T, natural killer T (NKT), and natural killer (NK) cells, during COVID-19. Interestingly, the decrease of CD73 on CD8+ T cells and NKT cells correlated with serum ferritin levels. Furthermore, we observed distinct functional differences between the CD73+ and CD73- subsets of CD8+ T cells and NKT cells with regard to cytokine/toxin secretion. In COVID-19 patients, the majority of the CD73-CD8+ T cells were capable of secreting granzyme B, perforin, tumor necrosis factor (TNF-α) or interferon-gamma (IFN-γ). To conclude, in this first study of CD39 and CD73 expression of lymphocytes in COVID-19, we show that CD8+ T cells and NKT cells lacking CD73 possess a significantly higher cytotoxic effector functionality compared to their CD73+ counterparts. Future studies should investigate differences of cellular CD39 and CD73 expression in patients at different disease stages and their potential as prognostic markers or targets for immunomodulatory therapies.

Verified
Journal Article
Open access
PDF file
MYming yan
ming yan
PHPhilip Hartjen
Philip Hartjen
MGMartin Gosau
Martin Gosau
TVTobias Vollkommer
Tobias Vollkommer
AGAudrey Laure Céline Grust
Audrey Laure Céline Grust
Anders HenningsenAnders Henningsen
Anders Henningsen
Cold plasma treatment increases the hydrophilicity of the surfaces of implants and may enhance their integration with the surrounding tissues. The implaPrep prototype device from Relyon Plasma generates cold atmospheric plasma via dielectric barrier discharge (DBD). In this study, titanium surfaces were treated with the implaPrep device for 20 s and assessed as a cell culture surface for fibroblasts. One day after seeding, significantly more cells were counted on the surfaces treated with cold plasma than on the untreated control titanium surface. Additionally, the viability assay revealed significantly higher viability on the treated surfaces. Morphological observation of the cells showed certain differences between the treated and untreated titanium surfaces. While conventional plasma devices require compressed gas, such as oxygen or argon, the implaPrep device uses atmospheric air as the gas source. It is, therefore, compact in size and simple to handle, and may provide a safe and convenient tool for treating the surfaces of dental implants, which may further improve the implantation outcome.

Verified
Journal Article
Open access
PDF file
PGPeter Gehrke
Peter Gehrke
PHPhilip Hartjen
Philip Hartjen
Ralf SmeetsRalf Smeets
Ralf Smeets
MGMartin Gosau
Martin Gosau
UPUlrike Peters
Ulrike Peters
SSSogand Schäfer
Sogand Schäfer
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.

17 March 2022 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
SSSogand Schäfer
Sogand Schäfer
Ralf SmeetsRalf Smeets
Ralf Smeets
MKMarius Köpf
Marius Köpf
ADAleksander Drinic
Aleksander Drinic
AKAlexander Kopp
Alexander Kopp
SFSandra Fuest
Sandra Fuest