Naresh Kumar Ravichandran

Prof. Naresh Kumar Ravichandran

Center for Scientific Instrumentation, Korea Basic Science Institute, Daejeon, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
SLSeung-Yeol Lee
Seung-Yeol Lee
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
SHSangyeop Han
Sangyeop Han
HJHyosang Jeong
Hyosang Jeong
JKJeehyun Kim
Jeehyun Kim
We developed a compact, wearable diagnostic imaging modality employing optical coherence tomography for in situ plant leaf quality assessments. This system is capable of diagnosing infected leaves at the initial disease stages. Our system is a versatile backpack-type imaging modality with a compact spectrometer, miniature computer, rechargeable power source, and handheld inspection probe. This method enhances real-time in situ specimen inspection through direct implementation of the imaging modality in a plantation. To evaluate the initial performance, field experiments were conducted in apple, pear, and persimmon plantations. Based on the obtained results, we can conclude that the developed imaging modality can be considered as a promising, efficient, convenient, and fast in situ inspection technique for various agricultural fields, which minimizes the limitations of complex tabletop inspection modalities.

1 January 2016 in Journal of Spectroscopy
Verified
Journal Article
Open access
PDF file
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
MSMuhammad Faizan Shirazi
Muhammad Faizan Shirazi
KPKibeom Park
Kibeom Park
SLSeung-Yeol Lee
Seung-Yeol Lee
JKJeehyun Kim
Jeehyun Kim
We have demonstrated the application of optical coherence tomography (OCT) in diagnosis of growth and spread of the gray leaf spot disease inCapsicum annuumleaf caused by the fungusStemphylium lycopersici. Using 2D cross-sectional and 3D volumetric images of OCT,in vivostudy of layer differences between fungus infected leaves and healthy leaves was observed with distinctive features. We observed that the internal layers of the disease-affected parts of the leaf seem to merge forming a single thick layer. The obtained OCT results verify the noninvasive diagnosis ability of fungal growth and spread inCapsicum annuumleaves and the applicability of this methodology for other plant diseases.

1 July 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
MSMuhammad Faizan Shirazi
Muhammad Faizan Shirazi
KPKibeom Park
Kibeom Park
Mansik JeonMansik Jeon
Mansik Jeon
JKJeehyun Kim
Jeehyun Kim
A method for depth enhancement is presented using a bidirectional imaging modality for spectral domain optical coherence tomography (SD-OCT). Two precisely aligned sample arms along with two reference arms were utilized in the optical configuration to scan the samples. Using exemplary images of the optical resolution target, Scotch tape, a silicon sheet with two needles, and a leaf, we demonstrated how the developed bidirectional SD-OCT imaging method increases the ability to characterize depth-enhanced images. The results of the developed system were validated by comparing the images with the standard OCT configuration (single-sample arm setup). Given the advantages of higher resolution and the ability to visualize deep morphological structures, this method can be utilized to increase the depth dependent fall-off in samples with limited thickness. Thus, the proposed bidirectional imaging modality is apt for cross-sectional imaging of entire samples, which has the potential capability to improve the diagnostic ability.

25 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
SLSeung-Yeol Lee
Seung-Yeol Lee
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
MSMuhammad Faizan Shirazi
Muhammad Faizan Shirazi
PKPilun Kim
Pilun Kim
JKJeehyun Kim
Jeehyun Kim
The tremendous advances achieved in the biophotonics technologies have intensified the necessity for non-invasive modalities that can characterize diverse biological materials with increased sensitivity and resolution. Optical coherence tomography (OCT) is one of the techniques that has been applied for biological applications in medicine and agriculture to identify structural properties. Herein, we report the successful incorporation of OCT for the identification of morphological changes that occur as a result of the bitter rot disease, through continuous detection of structural changes. Detailed inner morphological structural changes occurring in fruit specimens were precisely analyzed as a function of the disease incubation period using OCT. The conducted histological correlation and quantitative three-dimensional evaluations provide a robust platform for further discoveries related to plant materials. The results highlight the initial identification of bitter rot progression on apple specimens owing to the non-invasive inspection capability of OCT. Therefore, we expect that the proposed method will enable immediate sensitivity improvements in the inspection of plant diseases for postharvest utility.

1 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HLHemanth Tumkur Lakshmikantha
Hemanth Tumkur Lakshmikantha
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
MJMansik Jeon
Mansik Jeon
JKJeehyun Kim
Jeehyun Kim
HPHyo-sang Park
Hyo-sang Park
Microimplants are being used extensively in clinical practice to achieve absolute anchorage. Success of microimplant mainly depend on its primary stability onto the cortical bone surface and the associated Microdamage of the cortical bone during insertion procedure leads to many a microimplants to fail and dislodge from the cortical bone leading to its failure. Even though, previous studies showed occurrence of microdamage in the cortical bone, they were mainly 2-dimension studies or studies that were invasive to the host. In the present study, we used a non-invasive, non-ionizing imaging technique- Optical Coherence Tomography (OCT), to image and analyze the presence of microdamage along the cortical bone surrounding the microimplant. We inserted 80 microimplants in two different methods (drill and drill free method) and in two different angulations onto the cortical bone surface. Images were obtained in both 2D and 3D imaging modes. In the images, microdamage in form of microcracks on the cortical bone surface around the bone-microimplant interface and micro-elevations of the cortical bone in angulated microimplant insertions and the presence of bone debris due to screwing motion of the microimplant on insertion can be appreciated visually and quantitatively through the depth intensity profile analysis of the images.

7 November 2023 in Technologies
Verified
Journal Article
Open access
PDF file
MRMohomad Aqeel Abdhul Rahuman
Mohomad Aqeel Abdhul Rahuman
Nipun Shantha KahatapitiyaNipun Shantha Kahatapitiya
Nipun Shantha Kahatapitiya
Viraj NiroshanViraj Niroshan
Viraj Niroshan
Udaya WijenayakeUdaya Wijenayake
Udaya Wijenayake
BSBhagya Nathali Silva
Bhagya Nathali Silva
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
Bio-mechatronics is an interdisciplinary scientific field that emphasizes the integration of biology and mechatronics to discover innovative solutions for numerous biomedical applications. The broad application spectrum of bio-mechatronics consists of minimally invasive surgeries, rehabilitation, development of prosthetics, and soft wearables to find engineering solutions for the human body. Fiber-optic-based sensors have recently become an indispensable part of bio-mechatronics systems, which are essential for position detection and control, monitoring measurements, compliance control, and various feedback applications. As a result, significant advancements have been introduced for designing and developing fiber-optic-based sensors in the past decade. This review discusses recent technological advancements in fiber-optical sensors, which have been potentially adapted for numerous bio-mechatronic applications. It also encompasses fundamental principles, different types of fiber-optical sensors based on recent development strategies, and characterizations of fiber Bragg gratings, optical fiber force myography, polymer optical fibers, optical tactile sensors, and Fabry–Perot interferometric applications. Hence, robust knowledge can be obtained regarding the technological enhancements in fiber-optical sensors for bio-mechatronics-based interdisciplinary developments. Therefore, this review offers a comprehensive exploration of recent technological advances in fiber-optical sensors for bio-mechatronics. It provides insights into their potential to revolutionize biomedical and bio-mechatronics applications, ultimately contributing to improved patient outcomes and healthcare innovation.
1