Hongyun Wang

Prof. Dr. Hongyun Wang

Taizhou University, Taizhou, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
Hongyun WangHongyun Wang
Hongyun Wang
CBCheng Bi
Cheng Bi
A magnetorheological (MR) brake under compression-shear mode is designed, simulated and experimentally investigated in this paper. A MR brake under compression-shear mode was first designed considering compression enhanced shear yield stress of MR fluid. Then, the operating principle of the MR brake was illustrated and mathematical torque expressions, operating under compression-shear mode assuming Herschel–Bulkley model, was further established. Moreover, simulation analysis of the designed magnetic circuit was performed as well. An experimental prototype was fabricated and tested to evaluate the transmission performance of MR brake. The results showed that the large torque could be produced at high applied currents, high compressive stress, large compressive strain and small initial gap distances. The rotational speed and compressive speed had little effect on the torque. The characteristic rising time of the torque was greatly affected by the rotational speed, the compressive strain, and compressive speed. However, the current had little effect on the rising time. The time constant would became shorter when both the rotational speed and the compressive speed were faster. Through analyzing the compression of particle chains in MR fluids directly, it was found that the diameter and the length of the particles chains brought a strong influence on the essential property of MR fluids under compression. Thus, the compressive stress or compressive strain and the initial gap distance also played an important role in enhancing the torque. The results also showed that the proposed MR brake could generate a maximum torque of 241 Nm, about 17.9 times the magnitude of braking torque without compression, and achieve a high torque density of 125.6 kN m –2 and a time constant of 58 ms. This study provides a better understanding of MR brake under compression-shear mode and the implications for many high-power applications.

1 May 2011 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
PDF file
Hongyun WangHongyun Wang
Hongyun Wang
CBCheng Bi
Cheng Bi
JKJunwu Kan
Junwu Kan
CGChunfu Gao
Chunfu Gao
WXWang Xiao
Wang Xiao
The mechanical properties of a MR fluid in compression, elongation, and shearing have been studied in the magnetic field which is generated by a coil carrying different magnitudes of DC electrical current. Test equipment is designed to perform this operation. The compressing tests showed that the MR fluid is quite stiff at small compressive strains being lower than 0.13. The compressive stress and modulus increase quickly when the compressive strain is higher than 0.2. The tensile yield stress of MR fluids represents the effect of the interaction force between the polarized particles and the direction of the applied magnetic field. The shear yield stress represents the effect of the interaction force with the shear direction (perpendicular to the direction of the magnetic field). The relationship between tensile yield stress and shear yield stress verifies the credibility of the calculation model employing a yield angle shaped between particles. A shear yield angle is found to be between about 13.8° and 16.9°, which agrees with the shear yield angle tested well by other researchers. The tensile yield stress is about four times of shear yield stress.

9 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Hongyun WangHongyun Wang
Hongyun Wang
CBcheng bi
cheng bi
YZYongju Zhang
Yongju Zhang
AJAxiang Ji
Axiang Ji
PQPengyuan Qiu
Pengyuan Qiu
Transient behavior of a magnetorheological brake excited by step currents under compression-shear mode has been experimentally studied. The results show that the amplitude of the applied current had little effect on the rising time of transient torque, while the rising time was significantly affected by the rotational speed, the compressive speed and the compressive strain position. The falling time of transient torque was independent of the amplitude of the applied current, the compressive speed and the compressive strain position, and it was affected by the rotational speed. The falling time of the transient torque was much shorter than the rising time by a step current. The transient process of MR brake applied as a step current was different from a stable process pre-applied at constant current in different particle chain structure forming processes. In addition, the compressive processes applied in one step current and randomly on/off current were compared and experimentally verified: the particle chains in two processes both experienced the same evolutionary of transient torque. The results achieved in this study should be properly considered in the design and control of magnetorheological brake under compression-shear mode.

23 April 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CBCheng Bi
Cheng Bi
AJAxiang Ji
Axiang Ji
Hongyun WangHongyun Wang
Hongyun Wang
HWHaibo Wang
Haibo Wang
JZJunhua Zhu
Junhua Zhu
FZFenfen Zhou
Fenfen Zhou
Titanium alloy with high corrosion resistance, high strength-to-density ratio, and excellent biocompatibility has a wide range of applications in the field of biomedical implants. Polishing experiments of titanium alloy with a small size and complex shapes were investigated using an ultrasonic assisted magnetorheological finishing (UMRF) device excited by a three-pole magnetic field generator. The models of the normal force and the shear force were first proposed based on the Preston equation to analyze the mechanism of material removal in the UMRF process. Subsequently, the single-factor experiments using titanium alloy nuts (M3) and the MR polishing fluid with silicon carbide abrasives were carried out. Furthermore, to improve the surface roughness and the change rate of surface roughness of nuts, orthogonal tests with a standard L9(34) orthogonal array were designed and performed based on the optimized process parameters obtained from the single-factor experiment. The results indicated the effect on surface roughness and change rate of surface roughness as applied current > roller speed > ultrasonic amplitude > spindle speed and applied current > roller speed > spindle speed > ultrasonic amplitude, respectively. Moreover, the surface roughness was improved from an initial 1.247 μm to a final 0.104 μm after the polishing for 80 min under these optimal process parameters.

7 January 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CBCheng Bi
Cheng Bi
EBErda Bi
Erda Bi
Hongyun WangHongyun Wang
Hongyun Wang
CDChunlin Deng
Chunlin Deng
HCHuixin Chen
Huixin Chen
YWYun Wang
Yun Wang
The shear yield stress is an important parameter for the industrial application of magnetorheological (MR) fluids. A test equipment was designed and built to perform investigations on the behaviours of compression and shear after squeeze of MR fluids. Mathematical expression of magnetic flux density was further established. Furthermore, the magnetic field distribution of the test device based on two-coil mode and single-coil mode was simulated and compared using finite element analysis(ANSYS/Multiphysics). An experimental test system was fabricated and modified based on the final conditions and simulation results. The compression and shear after squeeze performances of MR fluids were tested. The results showed that a smaller initial gap distance or a larger compressive strain corresponds to a larger compressive stress under the same external magnetic field strength. The shear yield stress after the squeeze of MR fluids increases quickly with the increasing compression stress and the increasing magnetic flux density. This test equipment was thought to be suitable for studying the compression and shear after squeeze performances of MR fluids.

26 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Hongyun WangHongyun Wang
Hongyun Wang
CBcheng bi
cheng bi
YZYongju Zhang
Yongju Zhang
LZLi Zhang
Li Zhang
FZFenfen Zhou
Fenfen Zhou
Compressions of magnetorheological (MR) fluids have been carried out under instantaneous magnetic fields. The yield strength of the MR fluid in compressive mode has been derived by assuming that it was a transformed shear flow in Bi-visous model. The compressive stresses have experimentally studied under different magnetic fields, different initial gap distances and different compressive velocities. The nominal yield shear stresses of the compressed MR fluid under different influential factors have been calculated. The compressive stress increased in a power law as the applied magnetic field increased, while it decreased as the initial gap distance and the compressive velocity increased. With the increase of magnetic field, the difference between the nominal yield shear stress curves increased, and the exponents of the power law increased with the increase of the magnetic field strengths. A larger initial gap distance and a lower compressive velocity resulted in a higher nominal yield shear stress under the same instantaneous magnetic field. The achieved results of the nominal yield shear stress with magnetic field seemed to deviate from the prediction of dipole model, and the chain structure aggregation effect, the sealing effect and the friction effect by compression should be considered.