Mario Beretta

Dr. Mario Beretta

Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20133 Milan, Italy

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2018 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
CMCarlo Maiorana
Carlo Maiorana
LPL. Pivetti
L. Pivetti
FSF. Signorino
F. Signorino
GGGiovanni Battista Grossi
Giovanni Battista Grossi
AHA. S. Herford
A. S. Herford
Mario BerettaMario Beretta
Mario Beretta
When keratinized tissue width around dental implants is poorly represented, the clinician could resort to autogenous soft tissue grafting. Autogenous soft tissue grafting procedures are usually associated with a certain degree of morbidity. Collagen matrices could be used as an alternative to reduce morbidity and intra-operatory times. The aim of this study was to assess the efficacy of a xenogeneic collagen matrix as a substitute for soft tissue grafting around dental implants. Fifteen consecutive patients underwent a vestibuloplasty and keratinized tissue reconstruction around dental implants, both in the mandible and the maxilla, with a porcine collagen matrix. The so obtained keratinized tissues were measured and evaluated after 6 months and 1, 4, and 5 years. The average gain of keratinized tissue was 5.7 mm. After 6 months, it was observed a resorption of 37%, after 1 year 48%, and after 5 years 59%. The mean gain of keratinized tissue after 5 years was 2.4 mm. Hemostatic effect and post-operative pain were evaluated too. All subjects referred minimal pain with no bleeding. No adverse reaction nor infection was noted. The present study showed the efficacy of a porcine collagen matrix in keratinized tissue augmentation. The possibility to use a soft tissue substitute is a great achievement as morbidity decreases and bigger areas can be treated in a single surgery.

28 June 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
LGLuca Giboli
Luca Giboli
Mario BerettaMario Beretta
Mario Beretta
CMCarlo Maiorana
Carlo Maiorana
Matteo PellegriniMatteo Pellegrini
Matteo Pellegrini
Dental implant fractures pose a significant challenge to long-term treatment success. This systematic review aims to comprehensively examine the clinical factors influencing dental implant fractures (IFs). Furthermore, strategies to choose the right type of implant and prevent this complication are addressed. A systematic search was conducted across PubMed, Scopus, and Web of Science databases. Eligible studies included retrospective case–control, prospective cohort studies, and clinical trials. The initial search yielded 361 articles, of which 312 were excluded being these reviews, case reports, irrelevant, or written in languages other than English. This left 49 articles, with only 6 meeting the eligibility criteria for an in-depth review. These studies, all retrospective case–control, examine implant characteristics, patient demographics, surgical and prosthetic variables, biomechanical and functional factors, clinical and procedural variables, complications and maintenance issues. The risk of bias was assessed as low using the ROBINS-I tool. Key findings suggest a correlation between implant diameter and structural resistance, with wider implants demonstrating reduced fracture risk. Additionally, posterior regions, especially molars and premolars, exhibit higher susceptibility to IFs due to increased masticatory forces. Implant design and material may considerably influence fracture risk, with conical implants and screw-retained prostheses showing higher vulnerability. Biomechanical overload, particularly in patients with bruxism, emerges as a primary contributing factor to IFs. Prosthesis type significantly influences fracture incidence, with cantilever prostheses posing a higher risk due to increased stress. Peri-implant bone loss is strongly associated with IFs, emphasizing the need for meticulous preoperative assessments and individualized management strategies. Future research should prioritize larger and heterogeneous populations with long-term follow-up and standardized methodologies to enhance the generalizability and comparability of findings. Randomized controlled trials and biomechanical studies under controlled conditions are also essential to elucidate the complex interactions contributing to IFs and developing effective prevention strategies. Additionally, integrating patient-reported outcomes may offer a comprehensive understanding of the impact of IFs on quality of life.

25 November 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
LCLuca Creminelli
Luca Creminelli
APAlberto Porro
Alberto Porro
CMCarlo Maiorana
Carlo Maiorana
Mario BerettaMario Beretta
Mario Beretta
Objectives: A wide variety of approaches have been proposed to manage anticoagulant drugs in patients undergoing dental surgery; vitamin K antagonists and novel direct oral anticoagulants have been used. The present study aims to explore the existing evidence concerning the management of patients in anticoagulant therapy undergoing oral surgery procedures and to give suggestions related to peri- and post-operative measures. Materials and methods: A comprehensive search of databases was conducted to identify studies that evaluated the relationship between direct oral anticoagulants and dental procedures. The present scoping review was realized in adherence with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. The publications varied from randomized controlled trials (RCT) to cohort trials. Only articles written in English language and published between 2000 to 2020 were screened. The studies were included if discussing the management of a patient in anticoagulant therapy (warfarin or direct oral anticoagulants) scheduled for tooth extraction. Results: 33 studies were selected and included in the qualitative review. Nineteen considered anticoagulant therapy with warfarin, six considered anticoagulant therapy with new oral anticoagulants and eight compared patients taking warfarin with patients taking direct oral anticoagulants. Conclusions: No case of extractive surgery should alter the posology of the drug: thromboembolic risks derived from discontinuation are heavier than hemorrhagic risks. Clinical relevance: direct oral anticoagulants are safer in terms of bleeding and manageability and bleeding episodes are manageable with local hemostatic measures.

4 December 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
Mario BerettaMario Beretta
Mario Beretta
Matteo PellegriniMatteo Pellegrini
Matteo Pellegrini
FSFederica Eugenia Salina
Federica Eugenia Salina
CMCarlo Maiorana
Carlo Maiorana
Aim: Polydeoxyribonucleotide (PDRN) is a chain-like polymer derived from DNA. Recent in vitro and animal studies have showcased the beneficial impacts of PDRN on the process of bone mending, whether used on its own or in conjunction with other substances that aid in regeneration. This scoping review aims to synthesize the current understanding of how PDRNs influence bone healing. Materials and Methods: The studies included in the screening procedure were randomized controlled clinical trials (RCTs), both retrospective and prospective case–control studies, as well as in vitro and in vivo investigations. Articles were sourced from PubMed (MEDLINE), Scopus, EMBASE, Web of Science, and Google Scholar electronic databases using the following MeSH terms: (polydeoxyribonucleotide) and (bone) and (regeneration). Results: Initially, 228 articles were identified. Following the review process, a total of eight studies were ultimately examined. Among these, two were confined to laboratory studies, five were conducted on living organisms, and one encompassed both evaluations on living organisms and in vitro assessments. A descriptive qualitative approach was employed to present the data extracted from the studies that were included. Conclusions: PDRN has the potential to enhance the process of bone healing and the quantity of newly generated bone when combined with grafting materials. Future clinical studies are warranted to ascertain the appropriate clinical application of PDRN based on the dosage under consideration.

30 June 2025 in Medicina
Verified
Journal Article
Open access
PDF file
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
MGMartina Ghizzoni
Martina Ghizzoni
BCBeatrice Cusaro
Beatrice Cusaro
Mario BerettaMario Beretta
Mario Beretta
CMCarlo Maiorana
Carlo Maiorana
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
Implant primary stability is a prerequisite for obtaining osseointegration and clinical success. Insertion torque (IT) is measured during implant placement and is expressed in Ncm. It represents the quantification of the frictional force experienced by the implant as it progresses apically through a rotational motion along its axis. Usually, to achieve osseointegration, a value within the range of 20–40 Ncm is desirable. Below a threshold of 20 Ncm, implants have a decrease in survival rate, while implant stability is guaranteed above 20 Ncm. The main goal of this study was to evaluate whether high values of IT affect osseointegration, implant health, and healing, by highlighting the positive and negative effects of IT > 50 Ncm on peri-implant bone, soft tissues, and long-term stability. This scoping review considered randomized clinical trials, observational studies, and cohort studies. Studies failing to meet the predefined inclusion criteria were excluded from the analysis. The review process adhered to the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) guidelines. Ultimately, a total of 11 studies were included in the final synthesis. Based on the studies included, the literature suggests that high values of IT guarantee adequate primary stability and better osseointegration. However, high IT is significantly associated with greater marginal bone loss, depending on bone density. Accordingly, IT values > 50 Ncm may provoke greater compressive forces with a negative impact on the jawbone. An elevated strain on the bone can induce necrosis and ischemia, due to an alteration of circulation, which in turn is responsible for marginal bone loss and reduced osseointegration. Lack of osseointegration ultimately leads to an early implant failure. As concerns soft tissue recession, a higher decrease is measured in implants placed with high-insertion torque. Nonetheless, additional clinical trials are warranted to assess long-term outcomes, quantify the incidence of these complications, and explore the impact of emerging clinical variables.

1 November 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Mattia ManfrediniMattia Manfredini
Mattia Manfredini
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
CMCarlo Maiorana
Carlo Maiorana
FSFederica Eugenia Salina
Federica Eugenia Salina
MTMarco Tandurella
Marco Tandurella
Mario BerettaMario Beretta
Mario Beretta
This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation.