Marcos Rodriguez Torres

Dr. Marcos Rodriguez Torres

BUAP

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Marcos Rodriguez TorresMarcos Rodriguez Torres
Marcos Rodriguez Torres
VAVíctor Altuzar
Víctor Altuzar
CMClaudia Mendoza-Barrera
Claudia Mendoza-Barrera
Georgina Beltran PerezGeorgina Beltran Perez
Georgina Beltran Perez
JCJuan Castillo-Mixcóatl
Juan Castillo-Mixcóatl
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
A gas sensor array was developed and evaluated using four high-frequency quartz crystal microbalance devices (with a 30 MHz resonant frequency in fundamental mode). The QCM devices were coated with ethyl cellulose (EC), polymethylmethacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) sensing films, and deposited by the ultrasonic atomization method. The objective of this research was to propose a non-invasive technique for acetone biomarker detection, which is associated with diabetes mellitus disease. The gas sensor array was exposed to methanol, ethanol, isopropanol, and acetone biomarkers in four different concentrations, corresponding to 1, 5, 10, and 15 µL, at temperature of 22 °C and relative humidity of 20%. These samples were used because human breath contains them and they are used for disease detection. Moreover, the gas sensor responses were analyzed using principal component analysis and discriminant analysis, achieving the classification of the acetone biomarker with a 100% membership percentage when its concentration varies from 327 to 4908 ppm, and its identification from methanol, ethanol, and isopropanol.

6 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Marcos Rodriguez TorresMarcos Rodriguez Torres
Marcos Rodriguez Torres
VAVíctor Altuzar
Víctor Altuzar
CMClaudia Mendoza-Barrera
Claudia Mendoza-Barrera
Georgina Beltran PerezGeorgina Beltran Perez
Georgina Beltran Perez
JCJuan Castillo-Mixcóatl
Juan Castillo-Mixcóatl
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
The discrimination improvement of an array of four highly sensitive 30 MHz gas quartz crystal microbalance (QCM) sensors was performed and compared to a similar system based on a 12-MHz QCM. The sensing polymeric films were ethyl cellulose (EC), poly-methyl methacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) and they were coated over the AT-cut QCM devices by the drop casting technique. All the sensors had almost the same film thickness (0.2 μm). The fabricated QCM sensor arrays were exposed to three different concentrations, corresponding to 5, 10, and 15 μL, of ethanol, ethyl acetate, and heptane vapors. The steady state sensor responses were measured in a static system at a temperature of 20 °C and relative humidity of 22%. Our results showed that the 30-MHz sensors have a higher sensitivity than 12-MHz ones (around 5.73 times), independently of the sensing film and measured sample. On the other hand, principal component analysis and discriminant analysis were performed using the raw data of the responses. An improvement of the classification percentage between 12 MHz and 30 MHz sensors was found. However, it was not sufficient, especially for low concentrations. Furthermore, using partition coefficient and discriminant analysis (DA), an improvement of 100% classification of the three samples was achieved for the case of the 30-MHz sensor array.