Severino Muñoz-Aguirre

Dr. Severino Muñoz-Aguirre

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
AYAkihito Yoshino
Akihito Yoshino
TNTakamichi Nakamoto
Takamichi Nakamoto
TMToyosaka Moriizumi
Toyosaka Moriizumi

3 March 2006 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Georgina Beltran PerezGeorgina Beltran Perez
Georgina Beltran Perez
FLFrancisco Lopez
Francisco Lopez
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
JCJ. Castillo-Mixcóatl
J. Castillo-Mixcóatl
MMMartin Rodolfo Palomino Merino
Martin Rodolfo Palomino Merino
OPO. Portillo-Moreno
O. Portillo-Moreno

26 January 2011 in Journal of Sol-Gel Science and Technology
Verified
Journal Article
Closed access
PDF file
CLCarlos J. Lucio-Ortiz
Carlos J. Lucio-Ortiz
JRJavier Rivera De La Rosa
Javier Rivera De La Rosa
ARAracely Hernandez Ramírez
Aracely Hernandez Ramírez
JHJosé Antonio de los Reyes Heredia
José Antonio de los Reyes Heredia
PAPaz del Angel
Paz del Angel
LLLina M. De León-Covián
Lina M. De León-Covián

14 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Marcos Rodriguez TorresMarcos Rodriguez Torres
Marcos Rodriguez Torres
VAVíctor Altuzar
Víctor Altuzar
CMClaudia Mendoza-Barrera
Claudia Mendoza-Barrera
Georgina Beltran PerezGeorgina Beltran Perez
Georgina Beltran Perez
JCJuan Castillo-Mixcóatl
Juan Castillo-Mixcóatl
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
A gas sensor array was developed and evaluated using four high-frequency quartz crystal microbalance devices (with a 30 MHz resonant frequency in fundamental mode). The QCM devices were coated with ethyl cellulose (EC), polymethylmethacrylate (PMMA), Apiezon L (ApL), and Apiezon T (ApT) sensing films, and deposited by the ultrasonic atomization method. The objective of this research was to propose a non-invasive technique for acetone biomarker detection, which is associated with diabetes mellitus disease. The gas sensor array was exposed to methanol, ethanol, isopropanol, and acetone biomarkers in four different concentrations, corresponding to 1, 5, 10, and 15 µL, at temperature of 22 °C and relative humidity of 20%. These samples were used because human breath contains them and they are used for disease detection. Moreover, the gas sensor responses were analyzed using principal component analysis and discriminant analysis, achieving the classification of the acetone biomarker with a 100% membership percentage when its concentration varies from 327 to 4908 ppm, and its identification from methanol, ethanol, and isopropanol.

11 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JSJorge Edwin Sánchez-Sosa
Jorge Edwin Sánchez-Sosa
JCJuan Castillo-Mixcóatl
Juan Castillo-Mixcóatl
Georgina Beltran PerezGeorgina Beltran Perez
Georgina Beltran Perez
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
The source localization of gas leaks is important to avoid any potential danger to the surroundings or the probable waste of resources. Currently there are several localization methods using robotic systems that try to find the origin of a gas plume. Many of these methods require wind velocity information involving the use of commercial anemometric systems which are extremely expensive compared to metal oxide gas sensors. This article proposes the validation of the Gaussian plume model inside an empty room and its application to localize the source of a gas plume without employing anemometric sensors, exclusively using concentration data. The model was selected due to its simplicity and since it easily admits variants closer to reality, explaining the behavior of pollutants transported by the wind. An artificial gas source was generated by a conventional fan and liquid ethanol as contaminant. We found that the physical fan, far from making the model impossible to implement, enriched the information and added realism. The use of a robotic system capable of autonomously mapping the room concentration distribution is described. The results showed that the Gaussian plume model is applicable to localize our experimental gas source. An estimated position of the source with a deviation of 14 cm (6.1%) was obtained.

18 May 2010 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CMCarlos Martínez-Hipatl
Carlos Martínez-Hipatl
SMSeverino Muñoz-Aguirre
Severino Muñoz-Aguirre
GBGeorgina Beltrán-Pérez
Georgina Beltrán-Pérez
JCJuan Castillo-Mixcóatl
Juan Castillo-Mixcóatl
JRJavier Rivera De La Rosa
Javier Rivera De La Rosa