Davide Ippolito

Dr. Davide Ippolito

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Nutrition
Verified
Journal Article
Closed access
MSMarta Sandini
Marta Sandini
DBDavide P. Bernasconi
Davide P. Bernasconi
DFDavide Fior
Davide Fior
MMMatilde Molinelli
Matilde Molinelli
DIDavide Ippolito
Davide Ippolito
LGLuca Gianotti
Luca Gianotti

24 February 2021 in Critical Care
Verified
Journal Article
Open access
PDF file
ACAndrea Coppadoro
Andrea Coppadoro
ABAnnalisa Benini
Annalisa Benini
RFRobert Fruscio
Robert Fruscio
LVLuisa Verga
Luisa Verga
PMPaolo Mazzola
Paolo Mazzola
GFGiuseppe Foti
Giuseppe Foti
Background: Respiratory failure due to COVID-19 pneumonia is associated with high mortality and may overwhelm health care systems, due to the surge of patients requiring advanced respiratory support. Shortage of intensive care unit (ICU) beds required many patients to be treated outside the ICU despite severe gas exchange impairment. Helmet is an effective interface to provide continuous positive airway pressure (CPAP) noninvasively. We report data about the usefulness of helmet CPAP during pandemic, either as treatment, a bridge to intubation or a rescue therapy for patients with care limitations (DNI). Methods: In this observational study we collected data regarding patients failing standard oxygen therapy (i.e., non-rebreathing mask) due to COVID-19 pneumonia treated with a free flow helmet CPAP system. Patients’ data were recorded before, at initiation of CPAP treatment and once a day, thereafter. CPAP failure was defined as a composite outcome of intubation or death. Results: A total of 306 patients were included; 42% were deemed as DNI. Helmet CPAP treatment was successful in 69% of the full treatment and 28% of the DNI patients (P < 0.001). With helmet CPAP, PaO2/FiO2 ratio doubled from about 100 to 200 mmHg (P < 0.001); respiratory rate decreased from 28 [22–32] to 24 [20–29] breaths per minute, P < 0.001). C-reactive protein, time to oxygen mask failure, age, PaO2/FiO2 during CPAP, number of comorbidities were independently associated with CPAP failure. Helmet CPAP was maintained for 6 [3–9] days, almost continuously during the first two days. None of the full treatment patients died before intubation in the wards. Conclusions: Helmet CPAP treatment is feasible for several days outside the ICU, despite persistent impairment in gas exchange. It was used, without escalating to intubation, in the majority of full treatment patients after standard oxygen therapy failed. DNI patients could benefit from helmet CPAP as rescue therapy to improve survival. Trial Registration: NCT04424992

16 November 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
DIDavide Ippolito
Davide Ippolito
CCCristina Capraro
Cristina Capraro
ACAlessandra Casiraghi
Alessandra Casiraghi
CCCristina Cestari
Cristina Cestari
SSSandro Sironi
Sandro Sironi

1 May 2015 in British Journal of Radiology
Verified
Journal Article
Closed access
DIDavide Ippolito
Davide Ippolito
CFCammillo Talei Franzesi
Cammillo Talei Franzesi
DFD Fior
D Fior
Pietro Andrea BonaffiniPietro Andrea Bonaffini
Pietro Andrea Bonaffini
OMO Minutolo
O Minutolo
SSS Sironi
S Sironi
To assess the diagnostic quality of low dose (100 kV) CT angiography (CTA), by using ultra-low contrast medium volume (30 ml), for thoracic and abdominal aorta evaluation. 67 patients with thoracic or abdominal vascular disease underwent multidetector CT study using a 256 slice scanner, with low dose radiation protocol (automated tube current modulation, 100 kV) and low contrast medium volume (30 ml; 4 ml s(-1)). Density measurements were performed on ascending, arch, descending thoracic aorta, anonymous branch, abdominal aorta, and renal and common iliac arteries. Radiation dose exposure [dose-length product (DLP)] was calculated. A control group of 35 patients with thoracic or abdominal vascular disease were evaluated with standard CTA protocol (automated tube current modulation, 120 kV; contrast medium, 80 ml). In all patients, we correctly visualized and evaluated main branches of the thoracic and abdominal aorta. No difference in density measurements was achieved between low tube voltage protocol (mean attenuation value of thoracic aorta, 304 HU; abdominal, 343 HU; renal arteries, 331 HU) and control group (mean attenuation value of thoracic aorta, 320 HU; abdominal, 339; renal arteries, 303 HU). Radiation dose exposure in low tube voltage protocol was significantly different between thoracic and abdominal low tube voltage studies (490 and 324 DLP, respectively) and the control group (thoracic DLP, 1032; abdomen, DLP 1078). Low-tube-voltage protocol may provide a diagnostic performance comparable with that of the standard protocol, decreasing radiation dose exposure and contrast material volume amount. Low-tube-voltage-setting protocol combined with ultra-low contrast agent volume (30 ml), by using new multidetector-row CT scanners, represents a feasible diagnostic tool to significantly reduce the radiation dose delivered to patients and to preserve renal function, while also maintaining adequate diagnostic quality images in assessment of aorta.

1 February 2013 in European Journal of Radiology
Verified
Journal Article
Closed access
LMLetizia Monguzzi
Letizia Monguzzi
DIDavide Ippolito
Davide Ippolito
DBDavide Paolo Bernasconi
Davide Paolo Bernasconi
CTChiara Trattenero
Chiara Trattenero
SGStefania Galimberti
Stefania Galimberti
SSSandro Sironi
Sandro Sironi

1 July 2008 in Academic Radiology
Verified
Journal Article
Closed access
DIDavide Ippolito
Davide Ippolito
SSSandro Sironi
Sandro Sironi
MPMassimo Pozzi
Massimo Pozzi
LALaura Antolini
Laura Antolini
LRLaura Ratti
Laura Ratti
FFFerruccio Fazio
Ferruccio Fazio