Davide Fior

Davide Fior

Auto-generated profile, based on publicly available information

Davide Fior

Department of Radiology, Sant’Anna Hospital, ASST Lariana, 22100 Como, Italy

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Nutrition
Verified
Journal Article
Closed access
MSMarta Sandini
Marta Sandini
DBDavide P. Bernasconi
Davide P. Bernasconi
DFDavide Fior
Davide Fior
MMMatilde Molinelli
Matilde Molinelli
DIDavide Ippolito
Davide Ippolito
LGLuca Gianotti
Luca Gianotti

1 May 2015 in British Journal of Radiology
Verified
Journal Article
Closed access
DIDavide Ippolito
Davide Ippolito
CFCammillo Talei Franzesi
Cammillo Talei Franzesi
DFD Fior
D Fior
Pietro Andrea BonaffiniPietro Andrea Bonaffini
Pietro Andrea Bonaffini
OMO Minutolo
O Minutolo
SSS Sironi
S Sironi
To assess the diagnostic quality of low dose (100 kV) CT angiography (CTA), by using ultra-low contrast medium volume (30 ml), for thoracic and abdominal aorta evaluation. 67 patients with thoracic or abdominal vascular disease underwent multidetector CT study using a 256 slice scanner, with low dose radiation protocol (automated tube current modulation, 100 kV) and low contrast medium volume (30 ml; 4 ml s(-1)). Density measurements were performed on ascending, arch, descending thoracic aorta, anonymous branch, abdominal aorta, and renal and common iliac arteries. Radiation dose exposure [dose-length product (DLP)] was calculated. A control group of 35 patients with thoracic or abdominal vascular disease were evaluated with standard CTA protocol (automated tube current modulation, 120 kV; contrast medium, 80 ml). In all patients, we correctly visualized and evaluated main branches of the thoracic and abdominal aorta. No difference in density measurements was achieved between low tube voltage protocol (mean attenuation value of thoracic aorta, 304 HU; abdominal, 343 HU; renal arteries, 331 HU) and control group (mean attenuation value of thoracic aorta, 320 HU; abdominal, 339; renal arteries, 303 HU). Radiation dose exposure in low tube voltage protocol was significantly different between thoracic and abdominal low tube voltage studies (490 and 324 DLP, respectively) and the control group (thoracic DLP, 1032; abdomen, DLP 1078). Low-tube-voltage protocol may provide a diagnostic performance comparable with that of the standard protocol, decreasing radiation dose exposure and contrast material volume amount. Low-tube-voltage-setting protocol combined with ultra-low contrast agent volume (30 ml), by using new multidetector-row CT scanners, represents a feasible diagnostic tool to significantly reduce the radiation dose delivered to patients and to preserve renal function, while also maintaining adequate diagnostic quality images in assessment of aorta.

1 September 2014 in European Journal of Radiology
Verified
Journal Article
Closed access
DIDavide Ippolito
Davide Ippolito
DFDavide Fior
Davide Fior
Pietro Andrea BonaffiniPietro Andrea Bonaffini
Pietro Andrea Bonaffini
CCCristina Capraro
Cristina Capraro
DLDavide Leni
Davide Leni
SSSandro Sironi
Sandro Sironi

1 August 2015 in Medicine
Verified
Journal Article
Open access
MSMarta Sandini
Marta Sandini
DBDavide Paolo Bernasconi
Davide Paolo Bernasconi
DIDavide Ippolito
Davide Ippolito
LNLuca Nespoli
Luca Nespoli
MBMelissa Baini
Melissa Baini
LGLuca Gianotti
Luca Gianotti
The aim of this article is to assess whether measures of abdominal fat distribution, visceral density, and antropometric parameters obtained from computed tomography (CT) may predict postoperative pancreatic fistula (POPF) occurrence.We analyzed 117 patients who underwent pancreatoduodenectomy (PD) and had a preoperative CT scan as staging in our center. CT images were processed to obtain measures of total fat volume (TFV), visceral fat volume (VFV), density of spleen, and pancreas, and diameter of pancreatic duct. The predictive ability of each parameter was investigated by receiver-operating characteristic (ROC) curves methodology and assessing optimal cutoff thresholds. A stepwise selection method was used to determine the best predictive model.Clinically relevant (grades B and C) POPF occurred in 24 patients (20.5%). Areas under ROC-curves showed that none of the parameters was per se significantly predictive. The multivariate analysis revealed that a VFV >2334 cm, TFV >4408 cm, pancreas/spleen density ratio <0.707, and pancreatic duct diameter <5 mm were predictive of POPF. The risk of POPF progressively increased with the number of factors involved and age.It is possible to deduce objective information on the risk of POPF from a simple and routine preoperative radiologic workup.

16 January 2019 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
DFDavide Fior
Davide Fior
FVFrancesco Vacirca
Francesco Vacirca
DLDavide Leni
Davide Leni
FPFabio Pagni
Fabio Pagni
DIDavide Ippolito
Davide Ippolito
RCRocco Corso
Rocco Corso

1 January 2016 in World Journal of Gastroenterology
Verified
Journal Article
Open access
DIDavide Ippolito
Davide Ippolito
SDSilvia Girolama Drago
Silvia Girolama Drago
CFCammillo Talei Franzesi
Cammillo Talei Franzesi
DFDavide Fior
Davide Fior
SSSandro Sironi
Sandro Sironi
AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications.