Anh-Tuan Tran

Mr. Anh-Tuan Tran

Faculty of Electrical and Electronics Engineering, Ton Duc Thang University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2021 in Electronics
Verified
Journal Article
Open access
PDF file
VHVan-Van Huynh
Van-Van Huynh
MNMinh Bui Le Ngoc
Minh Bui Le Ngoc
EAEmmanuel Amaefule
Emmanuel Amaefule
ATAnh-Tuan Tran
Anh-Tuan Tran
PTPhong Tran Thanh
Phong Tran Thanh
This paper centers on the design of highly robust observer sliding mode (HROSM)-based load frequency and tie-power control to compensate for primary frequency control of multi-area interconnected power systems integrated with renewable power generation. At first, the power system with external disturbance is model in the state space form. Then the state observer is used to estimate the system states which are difficult or expensive to measure. Secondly, the sliding mode control (SMC) is designed with a new single phase sliding surface (SPSS). In addition, the whole system asymptotic stability is proven with Lyapunov stability theory based on the linear matrix inequality (LMI) technique. The new SPSS without reaching time guarantees rapid convergence of high transient frequency, tie-power change as well as reduces chattering without loss of accuracies. Therefore, the superiority of modern state-of-the-art SMC-based frequency controllers relies on good practical application. The experimental simulation results on large interconnected power systems show good performance and high robustness against external disturbances when compared with some modern state of art controllers in terms of overshoots and settling time.

16 June 2024
Verified
Conference Paper
Closed access
BPBang-Dang Pham
Bang-Dang Pham
PTPhong Tran
Phong Tran
ATAnh-Tuan Tran
Anh-Tuan Tran
CPCuong Pham
Cuong Pham
RNRang Nguyen
Rang Nguyen
MHMinh Hoai
Minh Hoai
This paper presents an innovative framework designed to train an image deblurring algorithm tailored to a specific camera device. This algorithm works by transforming a blurry input image, which is challenging to deblur, into another blurry image that is more amenable to deblurring. The transformation process, from one blurry state to another, leverages unpaired data consisting of sharp and blurry images captured by the target camera device. Learning this blur-to-blur transformation is inherently simpler than direct blur-to-sharp conversion, as it primarily involves modifying blur patterns rather than the intricate task of reconstructing fine image details. The efficacy of the proposed approach has been demonstrated through comprehensive experiments on various benchmarks, where it significantly outperforms state-of-the-art methods both quantitatively and qualitatively. Our code and data are available at https://github.com/VinAIResearch/Blur2Blur

1 January 2021 in Complexity
Verified
Journal Article
Open access
PDF file
ATAnh-Tuan Tran
Anh-Tuan Tran
BMBui Le Ngoc Minh
Bui Le Ngoc Minh
PTPhong Thanh Tran
Phong Thanh Tran
VHVan-Van Huynh
Van-Van Huynh
PDPhan Van Duc
Phan Van Duc
TNTam Minh Nguyen
Tam Minh Nguyen
Nowadays, the power systems are getting more and more complicated because of the delays introduced by the communication networks. The existence of the delays usually leads to the degradation and/or instability of power system performance. On account of this point, the traditional load frequency control (LFC) approach for power system sketches a destabilizing impact and an unacceptable system performance. Therefore, this paper proposes a new LFC based on adaptive integral second‐order sliding mode control (AISOSMC) approach for the large‐scale power system with communication delays (LSPSwCD). First, a new linear matrix inequality is derived to ensure the stability of whole power systems using Lyapunov stability theory. Second, an AISOSMC law is designed to ensure the finite time reachability of the system states. To the best of our knowledge, this is the first time the AISOSMC is designed for LFC of the LSPSwCD. In addition, the report of testing results presents that the suggested LFC based on AISOSMC can not only decrease effectively the frequency variation but also make successfully less in mount of power oscillation/fluctuation in tie‐line exchange.

7 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
ATAnh-Tuan Tran
Anh-Tuan Tran
MNMinh Bui Le Ngoc
Minh Bui Le Ngoc
VHVan-Van Huynh
Van-Van Huynh
PTPhong Tran Thanh
Phong Tran Thanh
EAEmmanuel Amaefule
Emmanuel Amaefule
TNTam Minh Nguyen
Tam Minh Nguyen
In multi-area interconnected power systems (MAIPS), the measurement of all system states is difficult due to the lack of a sensor or the fact that it is expensive to measure. In order to solve this limitation, a new load frequency controller based on the second-order sliding mode is designed for MAIPS where the estimated state variable is used fully in the sliding surface and controller. Firstly, a model of MAIPS integrated with disturbance is introduced. Secondly, an observer has been designed and used to estimate the unmeasured variables with disturbance. Thirdly, a new second-order sliding mode control (SOSMC) law is used to reduce the chattering in the system dynamics where slide surface and sliding mode controller are designed based on system states observer. The stability of the whole system is guaranteed via the Lyapunov theory. Even though state variables are not measured, the experimental simulation results show that the frequency remains in the nominal range under load disturbances, matched and mismatched uncertainties of the MAIPS. A comparison to other controllers illustrates the superiority of the highlighted controller designed in this paper.

6 March 2025 in IEEE Access
Verified
Journal Article
Open access
ATAnh-Tuan Tran
Anh-Tuan Tran
VHVan-Van Huynh
Van-Van Huynh
Jae Woong ShimJae Woong Shim
Jae Woong Shim
Chee Peng LimChee Peng Lim
Chee Peng Lim
This paper proposes an adaptive-based single-phase higher-order sliding mode controller (SMC) optimized by the honey badger algorithm (HBA). The developed control method is employed for load frequency control (LFC) in electrical power systems (EPSs) that incorporates a battery energy storage system (BESS) with droop control. Unlike conventional SMCs, the proposed higher-order SMC eliminates the reaching phase by utilizing the second derivative of the sliding motion and embedding the sliding surface directly within the original system, significantly reducing oscillations and chattering effects. Furthermore, an adaptive mechanism dynamically estimates the unknown bound of system uncertainties, enabling real-time compensation and minimizing steady-state errors. The system’s global stability is rigorously analyzed through linear matrix inequality (LMI) and Lyapunov stability theory, highlighting the robustness and practicality of the proposed method. To further enhance the system performance, the HBA is employed to optimize controller parameters, providing a balance between fast response and low overshoot. Additionally, a coordinated BESS control strategy integrating droop control and state-of-charge management is introduced, enabling seamless interaction between the energy storage system and generators to mitigate large disturbances in uncertain EPSs. Finally, extensive case studies under various configurations and conditions demonstrate the superior performance of the proposed controller compared to other related methods. Simulation results consistently confirm that the proposed solution outperforms alternative approaches across all scenarios. This is demonstrated by the minimal over/undershoot value in frequency deviations: 1.913 × 10−3 for the isolated EPS, 3.3134 × 10−4 and 0.6476 × 10−4 for two-area EPS equipped with ten BESS units. In the final case, the presence of BESS results in a significant reduction in peak value by approximately 22.9%, 16.5%, and 22.3% of each respective area of EPS.

9 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
VHVan-Van Huynh
Van-Van Huynh
PTPhong Tran Thanh
Phong Tran Thanh
MNMinh Bui Le Ngoc
Minh Bui Le Ngoc
ATAnh-Tuan Tran
Anh-Tuan Tran
TDTuan Huy Dao
Tuan Huy Dao
PVPhan-Tu Vu
Phan-Tu Vu
The implementation of the sliding mode control (SMC) for load frequency control of power networks becomes difficult due to the chattering phenomenon of high-frequency switching. This chattering problem in SMC is extremely dangerous for actuators used in power systems. In this paper, a continuous control strategy by combining a second-order mode and integral siding surface is proposed as a possible solution to this problem. The proposed second-order integral sliding mode control (SOISMC) law not only rejects chattering phenomenon in control input, but also guarantees the robustness of the multi-area power network, which has an effect on parametric uncertainties such as the load variations and the matched or mismatched parameter uncertainties. Moreover, the reporting of the simulation indicates that the proposed controller upholds the quality requirement by controlling with operating conditions in the larger range, rejects disturbance, reduces the transient response of frequency, eliminates the overshoot problem, and can better address load uncertainties compared to several previous control methods. The simulation results also show that the proposed SOISMC can be used for practical multi-area power network to lessen high parameter uncertainties and load disturbances.