This paper centers on the design of highly robust observer sliding mode (HROSM)-based load frequency and tie-power control to compensate for primary frequency control of multi-area interconnected power systems integrated with renewable power generation. At first, the power system with external disturbance is model in the state space form. Then the state observer is used to estimate the system states which are difficult or expensive to measure. Secondly, the sliding mode control (SMC) is designed with a new single phase sliding surface (SPSS). In addition, the whole system asymptotic stability is proven with Lyapunov stability theory based on the linear matrix inequality (LMI) technique. The new SPSS without reaching time guarantees rapid convergence of high transient frequency, tie-power change as well as reduces chattering without loss of accuracies. Therefore, the superiority of modern state-of-the-art SMC-based frequency controllers relies on good practical application. The experimental simulation results on large interconnected power systems show good performance and high robustness against external disturbances when compared with some modern state of art controllers in terms of overshoots and settling time.
In multi-area interconnected power systems (MAIPS), the measurement of all system states is difficult due to the lack of a sensor or the fact that it is expensive to measure. In order to solve this limitation, a new load frequency controller based on the second-order sliding mode is designed for MAIPS where the estimated state variable is used fully in the sliding surface and controller. Firstly, a model of MAIPS integrated with disturbance is introduced. Secondly, an observer has been designed and used to estimate the unmeasured variables with disturbance. Thirdly, a new second-order sliding mode control (SOSMC) law is used to reduce the chattering in the system dynamics where slide surface and sliding mode controller are designed based on system states observer. The stability of the whole system is guaranteed via the Lyapunov theory. Even though state variables are not measured, the experimental simulation results show that the frequency remains in the nominal range under load disturbances, matched and mismatched uncertainties of the MAIPS. A comparison to other controllers illustrates the superiority of the highlighted controller designed in this paper.
The implementation of the sliding mode control (SMC) for load frequency control of power networks becomes difficult due to the chattering phenomenon of high-frequency switching. This chattering problem in SMC is extremely dangerous for actuators used in power systems. In this paper, a continuous control strategy by combining a second-order mode and integral siding surface is proposed as a possible solution to this problem. The proposed second-order integral sliding mode control (SOISMC) law not only rejects chattering phenomenon in control input, but also guarantees the robustness of the multi-area power network, which has an effect on parametric uncertainties such as the load variations and the matched or mismatched parameter uncertainties. Moreover, the reporting of the simulation indicates that the proposed controller upholds the quality requirement by controlling with operating conditions in the larger range, rejects disturbance, reduces the transient response of frequency, eliminates the overshoot problem, and can better address load uncertainties compared to several previous control methods. The simulation results also show that the proposed SOISMC can be used for practical multi-area power network to lessen high parameter uncertainties and load disturbances.
To provide a more practical method of controlling the frequency and tie-line power flow of a multi-area interconnected power system (MAIPS), a state observer based on sliding mode control (SOboSMC) acting under a second-order time derivative is proposed. The proposed design is used to study load frequency control against load disturbance, matched and mismatched uncertainty and parameter measurement difficulties of power systems that exist in the modern power plant, such as multi-area systems integrated with wind plants. Firstly, the state observer is designed to optimally estimate system state variables. The estimated states are applied to construct the model of the MAIPS. Secondly, a SOboSMC is designed with an integral switching surface acting on the second-order time derivative to forcefully drive the dynamic errors to zero and eliminate chattering, which can occur in the first-order approach to sliding mode control. In addition, the stability of the total power system is demonstrated with the Lyapunov stability theory based on a new linear matrix inequality (LMI) technique. To extend the validation of the proposed design control for practical purposes, it was tested in a New England system with 39 bus power against random load disturbances. The simulation results confirm the superiority of the proposed SOboSMC over other recent controllers with respect to overshoot and settling time.
23 December 2018 in Advances in Electrical and Electronic Engineering