Bertrand Girardin

Mr. Bertrand Girardin

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2019 in Fire and Materials
Verified
Journal Article
Open access
PDF file
EGEric Guillaume
Eric Guillaume
DVDrean Virginie
Drean Virginie
BGBertrand Girardin
Bertrand Girardin
FBFaiz Benameur
Faiz Benameur
MKMaxime Koohkan
Maxime Koohkan
TFTalal FATEH
Talal FATEH
Summary: The dramatic event of the Grenfell Tower (June 2017), involving a combustible façade system, has raised concerns regarding the fire risk that these systems address. Indeed, as façades are complex systems, it is not straightforward to assess which part of the system is involved in the global fire behaviour. Understanding such façade fires is thus very complex as it depends on a combination of various products and system characteristics, including window frames or air gap or cavity barriers. Fire development inside the initial apartment was investigated using an appropriate CFD model with different scenarios for the fire source and ventilation conditions in a previous study. Fire propagation through the window to the external façade and to higher apartments was modelled and validated against visual observations. This paper describes CFD modelling of the complete Grenfell tower facade, and investigates vertical fire spread behaviour over the full height façade from the initial apartment. Contributions from the combustion of all the apartments' furniture, depending on window failure, and architectural details of the refurbished façade are considered in the numerical model. The modelling results are validated by comparison with photographic and video observations of the real fire.

17 November 2019 in Fire and Materials
Verified
Journal Article
Open access
PDF file
EGEric Guillaume
Eric Guillaume
DVDrean Virginie
Drean Virginie
BGBertrand Girardin
Bertrand Girardin
FBFaiz Benameur
Faiz Benameur
TFTalal FATEH
Talal FATEH
Summary: The Grenfell Tower fire occurred on 14 June 2017, killing 72 people. The pattern and speed of vertical and horizontal fire spread characterize this catastrophic event. Plentiful video and photographic data of the fire spread available has been carefully verified and concatenated into a database. The verified data have been superimposed on a projection of the Grenfell Tower in order to track the development of the fire. The surface that is unburnt, burning, or extinguished, as well as the presence of internal fire at any given location, is thus recorded for the duration of the fire. An analysis of the results showed that the initial vertical propagation can be divided into three phases. After the façade ignited at the fourth floor, vertical propagation over time is linear, with a vertical fire spread rate of around 3.5 m/min until the fire reached the sixth floor. Then fire propagation decelerated. Finally, fire spread accelerated with a power four dependence. The maximum vertical fire spread rate was around 8 m/min as the fire reached the crown at the top of the building. Horizontal spread proved to be greatest at the level of the crown (0.293 ± 0.005 m/min). There is a linear relationship between speed of horizontal fire spread and height. These correlations and observations yield important conclusions, and eight different hypotheses capable of explaining the global behaviour of the fire are suggested.

20 November 2015 in Materials
Verified
Journal Article
Open access
PDF file
BGBertrand Girardin
Bertrand Girardin
Gaelle FontaineGaelle Fontaine
Gaelle Fontaine
SDSophie Duquesne
Sophie Duquesne
MFMichael Försth
Michael Försth
Serge BourbigotSerge Bourbigot
Serge Bourbigot
The pyrolysis of solid polymeric materials is a complex process that involves both chemical and physical phenomena such as phase transitions, chemical reactions, heat transfer, and mass transport of gaseous components. For modeling purposes, it is important to characterize and to quantify the properties driving those phenomena, especially in the case of flame-retarded materials. In this study, protocols have been developed to characterize the thermal conductivity and the heat capacity of an ethylene-vinyl acetate copolymer (EVA) flame retarded with aluminum tri-hydroxide (ATH). These properties were measured for the various species identified across the decomposition of the material. Namely, the thermal conductivity was found to decrease as a function of temperature before decomposition whereas the ceramic residue obtained after the decomposition at the steady state exhibits a thermal conductivity as low as 0.2 W/m/K. The heat capacity of the material was also investigated using both isothermal modulated Differential Scanning Calorimetry (DSC) and the standard method (ASTM E1269). It was shown that the final residue exhibits a similar behavior to alumina, which is consistent with the decomposition pathway of EVA/ATH. Besides, the two experimental approaches give similar results over the whole range of temperatures. Moreover, the optical properties before decomposition and the heat capacity of the decomposition gases were also analyzed. Those properties were then used as input data for a pyrolysis model in order to predict gasification experiments. Mass losses of gasification experiments were well predicted, thus validating the characterization of the thermo-physical properties of the material.

11 September 2019 in Fire and Materials
Verified
Journal Article
Open access
PDF file
DVDrean Virginie
Drean Virginie
BGBertrand Girardin
Bertrand Girardin
EGEric Guillaume
Eric Guillaume
TFTalal FATEH
Talal FATEH
Summary: The recent fire events in buildings involving combustible cladding systems have raised concerns regarding the risk that these systems can pose. Understanding such facade fires is complex as they involve a combination of various products and system. Facade fire propagation tests at ISO 13785‐1 intermediate scale were performed on different combinations of aluminium composite material (ACM) claddings and insulants. Simulations were addressed to reproduce these tests and were validated in terms of thermal conditions in the system. This allowed additional investigation and understanding of fire propagation on the facade and more accurate determination of the fire behaviour of the overall system. In this paper, the scaling influence on the fire behaviour of ACM clad systems is investigated with simulations performed to reproduce fire tests at the BS8414‐1 larger scale on three different combinations of ACM and insulants. The contributions of the cladding and insulant were numerically investigated. The fire behaviour of each component and of the overall system is validated by comparison with experiments. Simulations and tests show that the ACM cladding is the most important element driving the global fire behaviour of the systems. In particular, ACM‐PE‐based cladding systems, whatever the insulant, show extensive fire propagation while its degradation affects the integrity of the cavity.

1 March 2015 in Polymer Degradation and Stability
Verified
Journal Article
Closed access
AWArtur Witkowski
Artur Witkowski
BGBertrand Girardin
Bertrand Girardin
MFMichael Försth
Michael Försth
FHFiona Hewitt
Fiona Hewitt
Gaelle FontaineGaelle Fontaine
Gaelle Fontaine
THT Richard Hull
T Richard Hull

17 November 2019 in Fire and Materials
Verified
Journal Article
Open access
PDF file
EGEric Guillaume
Eric Guillaume
DVDrean Virginie
Drean Virginie
BGBertrand Girardin
Bertrand Girardin
MKMaxime Koohkan
Maxime Koohkan
TFTalal FATEH
Talal FATEH
Summary: The dramatic event of the Grenfell Tower in 2017 reminds the importance of addressing fire issues as a whole and clearly highlighted one of the major roles played by the façade as fire propagation vector. To understand and analyse this disaster, numerical simulation allows particular phenomena to be evaluated more easily. The numerical model addressed for the fire behaviour of the façade system was developed using a multiscale approach and validated at different scales. In this paper, the fire behaviour of the façade and of its window frames is addressed. A computational fluid dynamics (CFD) model is used to investigate the fire spread from the initial apartment to the overall façade with different scenarios for the fire source and ventilation. Fire propagation through windows to the façade and to upper apartments is addressed. General curves representing the re‐entry of flames into upper apartment are extracted from simulations. The numerical results are validated by comparison with observations from videos and pictures of the real fire. Numerical results show that whatever the initial fire location and ventilation conditions, even if the fire source is of hundreds kilowatts, it is enough to ignite the adjacent element early and to the appearance of external flames shortly after.