Summary: The fire behaviour of a building façade is dependent on the overall system's performance, rather than the performance of the individual components. A façade system includes the cladding and the insulant's characteristics, but also the cavities, cavity barriers, mounting and fixings, substrate, and any singularities, such as window frames. This publication presents façade fire propagation test according to the ISO 13785‐1 standard, with additional heat release rate and gases analysis using FTIR. Tests have been performed on 9 different compositions of aluminium composite panels (ACM) with several insulants. For tested compositions, the cladding is the most important parameter driving global fire behaviour of façade mock‐ups. ACM‐PE‐based cladding systems gave very different results from the other solutions tested. This was especially visible in heat release rates, where fire intensity was very high, whatever the insulant used in the system. The contribution of the insulant was only remarkable in these tests during the decay phase. The cavity barrier was largely ineffectual in the 3 tests with ACM‐PE cladding, as the integrity of the cavity was not ensured.
Summary: The dramatic event of the Grenfell Tower (June 2017), involving a combustible façade system, has raised concerns regarding the fire risk that these systems address. Indeed, as façades are complex systems, it is not straightforward to assess which part of the system is involved in the global fire behaviour. Understanding such façade fires is thus very complex as it depends on a combination of various products and system characteristics, including window frames or air gap or cavity barriers. Fire development inside the initial apartment was investigated using an appropriate CFD model with different scenarios for the fire source and ventilation conditions in a previous study. Fire propagation through the window to the external façade and to higher apartments was modelled and validated against visual observations. This paper describes CFD modelling of the complete Grenfell tower facade, and investigates vertical fire spread behaviour over the full height façade from the initial apartment. Contributions from the combustion of all the apartments' furniture, depending on window failure, and architectural details of the refurbished façade are considered in the numerical model. The modelling results are validated by comparison with photographic and video observations of the real fire.
Summary: The Grenfell Tower fire occurred on 14 June 2017, killing 72 people. The pattern and speed of vertical and horizontal fire spread characterize this catastrophic event. Plentiful video and photographic data of the fire spread available has been carefully verified and concatenated into a database. The verified data have been superimposed on a projection of the Grenfell Tower in order to track the development of the fire. The surface that is unburnt, burning, or extinguished, as well as the presence of internal fire at any given location, is thus recorded for the duration of the fire. An analysis of the results showed that the initial vertical propagation can be divided into three phases. After the façade ignited at the fourth floor, vertical propagation over time is linear, with a vertical fire spread rate of around 3.5 m/min until the fire reached the sixth floor. Then fire propagation decelerated. Finally, fire spread accelerated with a power four dependence. The maximum vertical fire spread rate was around 8 m/min as the fire reached the crown at the top of the building. Horizontal spread proved to be greatest at the level of the crown (0.293 ± 0.005 m/min). There is a linear relationship between speed of horizontal fire spread and height. These correlations and observations yield important conclusions, and eight different hypotheses capable of explaining the global behaviour of the fire are suggested.