In this work, we present a photoplethy smography-based blood pressure monitoring algorithm (PPG-BPM) that solely requires a photoplethysmography (PPG) signal. The technology is based on pulse wave analysis (PWA) of PPG signals retrieved from different body locations to continuously estimate the systolic blood pressure (SBP) and the diastolic blood pressure (DBP). The proposed algorithm extracts morphological features from the PPG signal and maps them to SBP and DBP values using a multiple linear regression (MLR) model. The performance of the algorithm is evaluated on the publicly available Multiparameter Intelligent Monitoring in Intensive Care (MIMIC I) database. We utilize 28 data-sets (records) that contain both PPG and brachial arterial blood pressure (ABP) signals. The collected PPG and ABP signals are synchronized and divided into intervals of 30 seconds, called epochs. In total, we utilize 47153 clean 30-second epochs for the performance analysis. Out of the 28 data-sets, we use only 2 data-sets with a total of 2677 clean 30-second epochs to build the MLR model of the algorithm. For the SBP, a mean absolute error (MAE) of 6.10 mmHg between the arterial line and the PPG-based values are achieved, with a Pearson correlation coefficient r = 0.90, p = .001. For the DBP, and an MAE of 4.65 mmHg between the arterial line and the PPG-based values are achieved, with a Pearson correlation coefficient r = 0.85, p $\!<\!$ .001. We also use a binary classifier for the BP values with the positives indicating SBP $\geq$ 130 mmHg and/or DBP $\geq$ 80 mmHg and the negatives indicating otherwise. The classifier results generated by the PPG-based SBP and DBP estimates achieve a sensitivity and a specificity of 79.11% and 92.37%, respectively.
This paper presents the first low noise complementary metal oxide semiconductor (CMOS) terahertz (THz) imager based on source modulation and in-pixel high-Q filtering. The 31 × 31 focal plane array has been fully integrated in a 0 . 13 μ m standard CMOS process. The sensitivity has been improved significantly by modulating the active THz source that lights the scene and performing on-chip high-Q filtering. Each pixel encompass a broadband bow tie antenna coupled to an N-type metal-oxide-semiconductor (NMOS) detector that shifts the THz radiation, a low noise adjustable gain amplifier and a high-Q filter centered at the modulation frequency. The filter is based on a passive switched-capacitor (SC) N-path filter combined with a continuous-time broad-band Gm-C filter. A simplified analysis that helps in designing and tuning the passive SC N-path filter is provided. The characterization of the readout chain shows that a Q factor of 100 has been achieved for the filter with a good matching between the analytical calculation and the measurement results. An input-referred noise of 0 . 2 μ V RMS has been measured. Characterization of the chip with different THz wavelengths confirms the broadband feature of the antenna and shows that this THz imager reaches a total noise equivalent power of 0 . 6 nW at 270 GHz and 0 . 8 nW at 600 GHz.
30 October 2018 in IEEE Transactions on Electron Devices
In this paper, we propose a physics-based compact model of the pinned photodiode (PPD) combined with the transfer gate. A set of analytical expressions is derived for the 2-D electrostatic profile, the PPD capacitance, and the charge transfer current. The proposed model relies on the thermionic emission current mechanism, the barrier modulation, and the full-depletion approximation to obtain the charge transfer current. The proposed physics-based model is fully validated with technology computer-aided design simulations, i.e., stationary and optoelectrical simulations. The development of such a compact model for PPD represents an essential step toward the design, simulation, and optimization of PPD-based pixels in CMOS image sensors.
2 October 2019 in IEEE Transactions on Biomedical Circuits and Systems
Photoplethysmography (PPG) enables wearable vitals monitoring. Nevertheless, it is still limited by the few mA of the LEDs driving current. We present a PPG sensor integrating an array of dedicated pinned-photodiodes (PPD) with a full readout chain integrated in a 0.18 μm CMOS Image Sensor (CIS) process. The sensor features a total input referred noise of 0.68 e-rms per PPD, independently of the input light, and achieves a 4.6μW total power consumption, including the 2 μW LED power, at 1.38 bpm heart rate average error.
This paper presents an overview of the read noise in CMOS image sensors (CISs) based on four-transistors (4T) pixels, column-level amplification and correlated multiple sampling. Starting from the input-referred noise analytical formula, process level optimizations, device choices and circuit techniques at the pixel and column level of the readout chain are derived and discussed. The noise reduction techniques that can be implemented at the column and pixel level are verified by transient noise simulations, measurement and results from recently-published low noise CIS. We show how recently-reported process refinement, leading to the reduction of the sense node capacitance, can be combined with an optimal in-pixel source follower design to reach a sub-0.3 \(e^{-}_{rms}\) read noise at room temperature. This paper also discusses the impact of technology scaling on the CIS read noise. It shows how designers can take advantage of scaling and how the Metal-Oxide-Semiconductor (MOS) transistor gate leakage tunneling current appears as a challenging limitation. For this purpose, both simulation results of the gate leakage current and 1/f noise data reported from different foundries and technology nodes are used.
This work demonstrates that accurate hear beat monitoring, via photoplethysmography (PPG), can be performed at micro-power consumption level with an ear worn device. This is achieved thanks to the combination of a highly sensitive low power PPG chip, an optimal optical module, and an ergonomic design of the wearable device. The monolithic optical sensor is fabricated in a 180 nm CMOS image sensor (CIS) process and features an area of 1.5 mm by 1.5 mm only. It implements an array of pixels, newly designed for PPG, and reaching a quantum efficiency of 85 % up to 800 nm. The presented sensor consumes 60μA at 122 Hz sampling frequency, including digital communication. The optical design optimization enables high signal-to-noise ratio (SNR) PPG signals with less than 10μA average LED current. Heart beat monitoring, using the presented wearable device, is performed on 7 subjects and compared with a medical electrocardiogram (ECG). The earbud device correctly detects 98.47 % of the beats on a total of 72.21 hours of recordings. The inter-beat interval (IBI) estimation from these recordings features a mean absolute error (MAE) as low as 7.52 ms.