İlker Dursun

Prof. İlker Dursun

Sakarya University of Applied Sciences

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
OEOzan Erdinc
Ozan Erdinc
ATAkin Tascikaraoglu
Akin Tascikaraoglu
Nikolaos PaterakisNikolaos Paterakis
Nikolaos Paterakis
İlker Dursunİlker Dursun
İlker Dursun
MSMurat Can Sinim
Murat Can Sinim
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
The sizing and siting of renewable resources based distributed generation (DG) units has been a topic of growing interest, especially during the last decade due to the increasing interest in renewable energy systems and the possible impacts of their volatility on distribution system operation. This study goes beyond the existing literature by presenting a comprehensive optimization model for the sizing and siting of different renewable resources based DG units, electric vehicle (EV) charging stations and energy storage systems (ESSs) within the distribution system. The proposed optimization model is formulated as a second order conic programming problem, considering also the time-varying nature of DG generation and load consumption, in contrast with the majority of the relevant studies that have been based on static values.

12 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
İlker Dursunİlker Dursun
İlker Dursun
Sıtkı GünerSıtkı Güner
Sıtkı Güner
ISIbrahim Sengor
Ibrahim Sengor
AEAyşe Kübra Erenoğlu
Ayşe Kübra Erenoğlu
OEOzan Erdinc
Ozan Erdinc
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
Transformer buildings are at the heart of the effective operation of distribution systems, and heating problems of transformers under severe operational conditions are among the main factors affecting the lifetime, efficiency, technical losses, etc., of such important power system assets. It is crucial that the inside temperature of transformer buildings is higher than the outside temperature due to the operation of the transformer and the effect of ambient conditions. This issue may cause several problems such as additional transformer aging, losses, and moisture. The main purpose of this study is to decrease the inside temperature of transformer buildings; in other words, to prevent the inside temperature from being higher than the outside temperature. To realize this, it is recommended to apply a combined heat reduction technique by covering the outer surface with a reflective surface and use a low-emitting material on the inner surface. The relevant results of the practical evidence in this manner are presented in detail at a distribution system in Turkey with different climate and loading conditions in the summertime.

1 January 2025 in International Journal of Energy Research
Verified
Journal Article
Open access
İlker Dursunİlker Dursun
İlker Dursun
FMFurkan Menevşeoğlu
Furkan Menevşeoğlu
MVMETİN VARAN
METİN VARAN
MYMustafa Yılmaz
Mustafa Yılmaz
AÖAyfer Özer
Ayfer Özer
Ensuring voltage stability, minimizing technical losses, and reducing long‐term energy costs remain critical challenges in distribution networks with high photovoltaic (PV) penetration. This study introduces a unified optimization approach based on the bio‐inspired sea horse optimizer (SHO) to determine the optimal placement and sizing of second‐use battery energy storage systems (BESSs) in PV‐integrated radial networks. Unlike conventional single‐objective methods, the proposed SHO‐based multiobjective optimization simultaneously addresses five targets: (i) active power‐loss reduction, (ii) voltage‐profile improvement, (iii) operating‐cost minimization, (iv) reliability enhancement through the loss of power supply probability (LPSP), and (v) economic feasibility via the levelized cost of energy (LCE). A 24‐h MATPOWER simulation was carried out on the IEEE‐33 and IEEE‐69 bus systems, incorporating realistic PV generation, time‐varying loads, and constrained BESS operation with state‐of‐health (SoH) and depth‐of‐discharge (DoD) limits, state‐of‐charge (SOC) between 20% and 85%, and round‐trip efficiency of 80%–83%. For the IEEE‐33 system, the optimal configuration deployed 1200 kWh BESS and 1000 kW PV, reducing power loss from 219.3 to 20.55 kW (≈90.6% reduction), improving the minimum voltage to 0.968 p.u., lowering voltage deviation to 1.2%, cutting LPSP from 42% to 18%, and decreasing LCE from 110 to 85 $/MWh. For the IEEE‐69 system, the optimized allocation of 1500 kWh BESS and 1500 kW PV reduced losses from 225.3 to 31.86 kW (≈85.9% reduction), increased the minimum voltage to 0.965 p.u., reduced deviation to 2.1%, lowered LPSP from 31% to 12%, and decreased LCE from 96 to 85 $/MWh. Comparative analysis against genetic algorithm (GA), WOA, and CSA confirmed that the SHO algorithm consistently achieved the lowest losses and fastest convergence. Overall, the SHO‐based multiobjective optimization approach effectively determines both placement and sizing of PV and second‐use BESS, ensuring technical efficiency, improved reliability, and economic sustainability for modern distribution networks.

1 January 2016 in International Journal of Electronics and Electrical Engineering
Verified
Journal Article
Closed access
ICİstanbul Bogazici Electricity Distribution Company
İstanbul Bogazici Electricity Distribution Company
İlker Dursunİlker Dursun
İlker Dursun
FKFeyzi Karaosmanoğlu
Feyzi Karaosmanoğlu
NUNurettin Umurkan
Nurettin Umurkan
International Journal of Electronics and Electrical Engineering

10 September 2026 in Cluster Computing
Verified
Journal Article
Closed access
PDF file
İlker Dursunİlker Dursun
İlker Dursun
AEAleyna Erkara
Aleyna Erkara

30 November 2023 in Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi
Verified
Journal Article
Open access
PDF file
İlker Dursunİlker Dursun
İlker Dursun
Artan nüfus, gelişen sanayi ve teknoloji, enerjiye olan talebi her geçen arttırmaktadır. Bununla beraber, küresel ısınma, iklim değişiklikleri ve sürdürülebilirlik gibi etkenler, ilgiyi yenilebilir enerjiye kaydırmaktadır. Ancak yenilebilir enerji sistemlerinin de düzensiz üretim rejimleri nedeniyle, elektrik şebekelerinde istenilen esneklik sağlanamamaktadır. Bu soruna çözüm olarak, yenilenebilir enerji sistemlerinde enerji depolama tesislerinin kurulması fikri ortaya çıkmıştır. Bu çalışmada, bir üniversite yerleşkesinin bir yıllık gerçek elektrik tüketim değerleri incelenmiş, bu yerleşkeye enerji depolamalı bir güneş enerji sisteminin (GES) kurulması durumundaki elektrik üretim ve tüketim değerleri analiz edilmiş, enerji depolama sistemi ile tepe yük tıraşlama yapılarak yük profilinin iyileştirilmesi gerçekleştirilmiştir. Günlük, haftalık, aylık ve yıllık enerji üretim-tüketim değerleri detaylı olarak incelenmiş, yaz ve kış dönemlerinde elektrik üretim ve tüketim profillerindeki değişim, yük tıraşlama ve yenilebilir enerji üretimi ile elektrik şebekesine olan katkılarla beraber, çevresel ve ekonomik etkiler de ele alınmıştır.