At present, millimeter wave radar imaging technology has become a recognized human security solution in the field. The millimeter wave radar imaging system can be used to detect a concealed object; multiple-input multiple-output radar antennas and synthetic aperture radar techniques are used to obtain the raw data. The analytical Fourier transform algorithm is used for image reconstruction. When imaging a target at 90 mm from radar, which belongs to the near field imaging scene, the image resolution can reach 1.90 mm in X-direction and 1.73 mm in Y-direction. Since the error caused by the distance between radar and target will lead to noise, the original reconstruction image is processed by gamma transform, which eliminates image noise, then the image is enhanced by linearly stretched transform to improve visual recognition, which lays a good foundation for supervised learning. In order to flexibly deploy the machine learning algorithm in various application scenarios, ShuffleNetV2, MobileNetV3 and GhostNet representative of lightweight convolutional neural networks with redefined convolution, branch structure and optimized network layer structure are used to distinguish multi-category SAR images. Through the fusion of squeeze-and-excitation and the selective kernel attention mechanism, more precise features are extracted for classification, the proposed GhostNet_SEResNet56 can realize the best classification accuracy of SAR images within limited resources, which prediction accuracy is 98.18% and the number of parameters is 0.45 M.
To reduce the high pre-weaning mortality rate of new-born piglets crushed by sows, a kind of recognition and evaluation method for sows' behavior based on the scheme of time-sharing and multiplexing by adopting triaxial acceleration and video sensors at day and night is proposed in this paper. For darker scene at night, random forest classifier with optimal 43-dimensional feature vector subset proposed in this paper is adopted to recognize four kinds of macro behaviors of sows roughly by adopting triaxial acceleration sensor MPU6050. The recognition rate can reach 89.4%. For brighter light scene during the day, an improved bilinear convolutional neural network method based on CBAM module is proposed in this paper to recognize seven kinds of micro behaviors of sows by video sensor. The recognition rate can reach 84.4%. The methods proposed in this paper can meet the requirement of real-time to recognize the behavior of sows during 24 hours on the premise of ensuring accuracy. Finally, an evaluation model of sows' maternal behavior level is set up in this paper. The achivement of the study can not only help the farm to select sows with higher maternal ability for breeding piglets, but also avoid the large-scale economic losses caused by the high mortality rate of piglets before weaning of the farm.
In this paper, a multiband noncontact temperature-measuring microwave radiometer system is developed. The system can passively receive the microwave signal of the core temperature field of the human body without removing the clothes of the measured person. In order to accurately measure the actual temperature of multilayer tissue in human core temperature field, four frequency bands of 4–6 GHz, 8–12 GHz, 12–16 GHz, and 14–18 GHz were selected for multifrequency design according to the internal tissue depth model of human body and the relationship between skin depth and electromagnetic frequency. Used to measure the actual temperature of human epidermis, dermis, and subcutaneous tissue, a small and highly directional multiband angular horn antenna was designed for the radiometer front end. After the error analysis of the full-power microwave radiometer, a novel hardware architecture of the microwave interferometric temperature-measuring radiometer is proposed, and it is proven that the novel interferometric microwave radiometer has less error uncertainty through theoretical deduction. The experimental results show that the maximum detection sensitivity of the novel interferometric microwave temperature-measuring radiometer is 215 mV/dBm, and the temperature sensitivity is 0.047 K/mV. Compared with the scheme of the full-power radiometer, the detection sensitivity is increased 7.45-fold, and the temperature sensitivity is increased 13.89-fold.
In this paper, the key technology of interferometric microwave thermometer is studied, the research can be applied to the temperature measurement of human body and subcutaneous tissue. This paper proposes a hardware architecture of interferometric microwave thermometer with 2 GHz bandwidth, in which the phase shifter is used to correct phase error and the quadrature demodulator is used to realize autocorrelation detection function. The results show that when input power is 7 dBm, the detection sensitivity can reach 176.54 mV/dBm and the temperature resolution of the microwave radiometer can reach 0.4 K. Correction algorithm is designed to improve the accuracy of temperature measurement. After correction, the phase error is reduced from 40° to 1.4° and when temperature changes 0.1 °C, the voltage value changes obviously. Step-by-step calibration and overall calibration are used to calibrate the device. Inversion algorithm can determine the relationship between physical temperature and output voltage. The mean square error of water temperature inversion by multiple linear regression algorithm is 0.607 and that of BP neural network algorithm is 0.334. The inversion accuracy can be improved by reducing the temperature range. Our work provides a promising realization of accurate, rapid and non-contact detection device of human body temperature.
Microwave radiometry (MWR) is instrumental in detecting thermal variations in skin tissue before anatomical changes occur, proving particularly beneficial in the early diagnosis of cancer and inflammation. This study concisely traces the evolution of microwave radiometers within the medical sector. By analyzing a plethora of pertinent studies and contrasting their strengths, weaknesses, and performance metrics, this research identifies the primary factors limiting temperature measurement accuracy. The review establishes the critical technologies necessary to overcome these limitations, examines the current state and prospective advancements of each technology, and proposes comprehensive implementation strategies. The discussion elucidates that the precise measurement of human surface and subcutaneous tissue temperatures using an MWR system is a complex challenge, necessitating an integration of antenna directionality for temperature measurement, radiometer error correction, hardware configuration, and the calibration and precision of a multilayer tissue forward and inversion method. This study delves into the pivotal technologies for non-invasive human tissue temperature monitoring in the microwave frequency range, offering an effective approach for the precise assessment of human epidermal and subcutaneous temperatures, and develops a non-contact microwave protocol for gauging subcutaneous tissue temperature distribution. It is anticipated that mass-produced measurement systems will deliver substantial economic and societal benefits.