Existing treatments for Alzheimer’s disease (AD) have questionable efficacy with a need for research into new and more effective therapies to both treat and possibly prevent the condition. This review examines a novel therapeutic modality that shows promise for treating AD based on modulating neuronal activity in the gamma frequency band through external brain stimulation. The gamma frequency band is roughly defined as being between 30 Hz-100 Hz, with the 40 Hz point being of particular significance. The epidemiology, diagnostics, existing pathological models, and related current treatment targets are initially briefly reviewed. Next, the concept of external simulation triggering brain activity in the gamma band with potential demonstration of benefit in AD is introduced with reference to a recent important study using a mouse model of the disease. The review then presents a selection of relevant studies that describe the neurophysiology involved in brain stimulation by external sources, followed by studies involving application of the modality to clinical scenarios. A table summarizing the results of clinical studies applied to AD patients is also reported and may aid future development of the modality. The use of a therapy based on modulation of gamma neuronal activity represents a novel non-invasive, non-pharmacological approach to AD. Although use in clinical scenarios is still a relatively recent area of research, the technique shows good signs of efficacy and may represent an important option for treating AD in the future.
29 August 2018 in Medical & Biological Engineering & Computing
Objective : Multi-frequency symmetry difference electrical impedance tomography (MFSD-EIT) can robustly detect and identify unilateral perturbations in symmetric scenes. Here, an investigation is performed to assess if the algorithm can be successfully applied to identify the aetiology of stroke with the aid of machine learning. Methods : Anatomically realistic four-layer finite element method models of the head based on stroke patient images are developed and used to generate EIT data over a 5 Hz–100 Hz frequency range with and without bleed and clot lesions present. Reconstruction generates conductivity maps of each head at each frequency. Application of a quantitative metric assessing changes in symmetry across the sagittal plane of the reconstructed image and over the frequency range allows lesion detection and identification. The algorithm is applied to both simulated and human (n = 34 subjects) data. A classification algorithm is applied to the metric value in order to differentiate between normal, haemorrhage and clot values. Main results : An average accuracy of 85% is achieved when MFSD-EIT with support vector machines (SVM) classification is used to identify and differentiate bleed from clot in human data, with 77% accuracy when differentiating normal from stroke in human data. Conclusion : Applying a classification algorithm to metrics derived from MFSD-EIT images is a novel and promising technique for detection and identification of perturbations in static scenes. Significance : The MFSD-EIT algorithm used with machine learning gives promising results of lesion detection and identification in challenging conditions like stroke. The results imply feasible translation to human patients.
Brain haemorrhages often require urgent treatment with a consequent need for quick and accurate diagnosis. Therefore, in this study, we investigate Support Vector Machine (SVM) classifiers for detecting brain haemorrhages using Electrical Impedance Tomography (EIT) measurement frames. A 2-layer model of the head, along with a series of haemorrhages, is designed as both numerical models and physical phantoms. EIT measurement frames, taken from an electrode array placed on the head surface, are used to train and test linear SVM classifiers. Various scenarios are implemented on both platforms to examine the impact of variables such as noise level, lesion location, lesion size, variation in electrode positioning, and variation in anatomy, on the classifier performance. The classifier performed well in numerical models (sensitivity and specificity of 90%+) with signal-to-noise ratios of 60 dB+, was independent of lesion location, and could detect lesions reliably down to the tested minimum volume of 5 ml. Slight variations in electrode layout did not affect performance. Performance was affected by variations in anatomy however, emphasising the need for large training sets covering different anatomies. The phantom models proved more challenging, with maximal sensitivity and specificity of 75% when used with the linear SVM. Finally, the performance of two more complex classifiers is briefly examined and compared to the linear SVM classifier. These results demonstrate that a radial basis function (RBF) SVM classifier and a neural network classifier can improve detection accuracy. Classifiers applied to EIT measurement frames is a novel approach for lesion detection and may offer an effective diagnostic tool clinically. A challenge is to translate the strong results from numerical models into real world phantoms and ultimately human patients, as well as the selection and development of optimal classifiers for this application.
The evaluation of the microwave imaging (MWI) prototype and imaging algorithms on experimental bone phantoms is a precursor step before clinical testing for measuring in vivo dielectric properties of human bones. To this end, this paper presents microwave tomographic image reconstruction of experimental phantoms of normal and diseased human calcaneus bone using an MWI prototype and distorted Born iterative method (DBIM) algorithm for bone health monitoring application. A two-layered simplified cylindrical-shaped 3-D printed phantom was used to mimic the human calcaneus bone. The external and internal layers of the bone phantom mimic the cortical bone and trabecular bone, respectively. Liquid tissue-mimicking mixtures (TMM) for normal bone, osteoporotic bone, and osteoarthritis bone were prepared. The phantoms were placed in the imaging prototype and the electromagnetic inverse scattering problem was solved using the DBIM to create the complex permittivity images. An $L_{2}$ -based regularization approach was adopted along with the iterative method with adaptive thresholding for compressed sensing (IMATCS) to overcome the ill-posedness and to solve the underdetermined set of linear equations at each DBIM iteration. The reconstruction of dielectric properties of bone phantoms have shown that $L_{2}$ -IMATCS approach provides a robust reconstruction of diverse bone phantoms with acceptable accuracy. Moreover, the osteoporotic and osteoarthritis bone phantoms were distinguished based on reconstructed dielectric properties with an average percentage difference of 26% at 3 GHz. This paper has made the first attempt to validate an MWI prototype for bone imaging application. A DBIM-based iterative method has been employed to classify normal and diseased bone phantoms.
19 December 2019 in IEEE Journal of Biomedical and Health Informatics
Bi-Frequency Symmetry Difference (BFSD)-EIT can detect, localize and identify unilateral perturbations in symmetric scenes. Here, we test the viability and robustness of BFSD-EIT in stroke diagnosis. A realistic 4-layer Finite Element Method (FEM) head model with and without bleed and clot lesions is developed. Performance is assessed with test parameters including: measurement noise, electrode placement errors, contact impedance errors, deviations in assumed tissue conductivity, deviations in assumed anatomy, and a frequency-dependent background. A final test is performed using ischemic patient data. Results are assessed using images and quantitative metrics. BFSD-EIT may be feasible for stroke diagnosis if a signal-to-noise ratio (SNR) of ≥60dB is achievable. Sensitivity to errors in electrode positioning is seen with a tolerance of only ±5mm, but a tolerance of up to ±30mm is possible if symmetry is maintained between symmetrically opposite partner electrodes. The technique is robust to errors in contact impedance and assumed tissue conductivity up to at least ±50%. Asymmetric internal anatomy affects performance but may be tolerable for tissues with frequency-dependent conductivity. Errors in assumed external geometry marginally affect performance. A frequency-dependent background does not affect performance with carefully chosen frequency points or use of multiple frequency points across a band. The Global Left-Hand Side (LHS) & Right-Hand Side (RHS) Mean Intensity metric is particularly robust to errors. BFSD-EIT is a promising technique for stroke diagnosis, provided parameters are within the tolerated ranges. BFSD-EIT may prove an important step forward in imaging of static scenes such as stroke.