Atif Shahzad

Dr. Atif Shahzad

University of Birmingham, Birmingham, UK
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2018 in Diagnostics
Verified
Journal Article
Open access
PDF file
AGAlessandra La Gioia
Alessandra La Gioia
Emily PorterEmily Porter
Emily Porter
IMIlja Merunka
Ilja Merunka
ASAtif Shahzad
Atif Shahzad
SSSaqib Salahuddin
Saqib Salahuddin
MOMartin Ohalloran
Martin Ohalloran
Electromagnetic (EM) medical technologies are rapidly expanding worldwide for both diagnostics and therapeutics. As these technologies are low-cost and minimally invasive, they have been the focus of significant research efforts in recent years. Such technologies are often based on the assumption that there is a contrast in the dielectric properties of different tissue types or that the properties of particular tissues fall within a defined range. Thus, accurate knowledge of the dielectric properties of biological tissues is fundamental to EM medical technologies. Over the past decades, numerous studies were conducted to expand the dielectric repository of biological tissues. However, dielectric data is not yet available for every tissue type and at every temperature and frequency. For this reason, dielectric measurements may be performed by researchers who are not specialists in the acquisition of tissue dielectric properties. To this end, this paper reviews the tissue dielectric measurement process performed with an open-ended coaxial probe. Given the high number of factors, including equipment- and tissue-related confounders, that can increase the measurement uncertainty or introduce errors into the tissue dielectric data, this work discusses each step of the coaxial probe measurement procedure, highlighting common practices, challenges, and techniques for controlling and compensating for confounders.

24 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TITalha Iqbal
Talha Iqbal
ASAndrew Simpkin
Andrew Simpkin
DSDavood Roshan Sangachin
Davood Roshan Sangachin
NGNicola Glynn
Nicola Glynn
JKJohn Killilea
John Killilea
ASAtif Shahzad
Atif Shahzad
With the recent advancements in the field of wearable technologies, the opportunity to monitor stress continuously using different physiological variables has gained significant interest. The early detection of stress can help improve healthcare and minimizes the negative impact of long-term stress. This paper reports outcomes of a pilot study and associated stress-monitoring dataset, named the “Stress-Predict Dataset”, created by collecting physiological signals from healthy subjects using wrist-worn watches with a photoplethysmogram (PPG) sensor. While wearing these watches, 35 healthy volunteers underwent a series of tasks (i.e., Stroop color test, Trier Social Stress Test and Hyperventilation Provocation Test), along with a rest period in-between each task. They also answered questionnaires designed to induce stress levels compatible with daily life. The changes in the blood volume pulse (BVP) and heart rate were recorded by the watch and were labelled as occurring during stress-inducing tasks or a rest period (no stress). Additionally, respiratory rate was estimated using the BVP signal. Statistical models and personalised adaptive reference ranges were used to determine the utility of the proposed stressors and the extracted variables (heart rate and respiratory rate). The analysis showed that the interview session was the most significant stress stimulus, causing a significant variation in heart rate of 27 (77%) participants and respiratory rate of 28 (80%) participants out of 35. The outcomes of this study contribute to the understanding the role of stressors and their association with physiological response and provide a dataset to help develop new wearable solutions for more reliable, valid, and sensitive physio-logical stress monitoring.

25 March 2020 in European Heart Journal
Verified
Journal Article
Open access
PDF file
FMFelix Mahfoud
Felix Mahfoud
MAMichel Azizi
Michel Azizi
SESebastian Ewen
Sebastian Ewen
APAtul Pathak
Atul Pathak
CUChristian Ukena
Christian Ukena
WWWilliam Wijns
William Wijns
Device-based hypertension treatment is a complementary and possibly alternative approach to conventional lifestyle changes combined with antihypertensive medications to achieve and maintain optimal blood pressure (BP) control. A series of clinical trials assessing novel technologies are currently ongoing for device-based hypertension treatment, including endovascular catheter-based renal denervation (RDN), baroreceptor activation therapy, endovascular baroreflex amplification, and cardiac pacemaker-mediated hypertension treatment.

7 April 2022 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
Talha IqbalTalha Iqbal
Talha Iqbal
AEAdnan Elahi
Adnan Elahi
SGSandra Ganly
Sandra Ganly
WWWilliam Wijns
William Wijns
ASAtif Shahzad
Atif Shahzad
Purpose: Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method. Methods: This paper proposes a new algorithm to estimate the respiratory rate using a photoplethysmography sensor signal for health monitoring. The algorithm is resistant to signal loss and can handle low-quality signals from the sensor. It combines selective windowing, preprocessing and signal conditioning, modified Welch filtering and postprocessing to achieve high accuracy and robustness to noise. Results: The Mean Absolute Error and the Root Mean Square Error of the proposed algorithm, with the optimal signal window size, are determined to be 2.05 breaths count per minute and 2.47 breaths count per minute, respectively, when tested on a publicly available dataset. These results present a significant improvement in accuracy over previously reported methods. The proposed algorithm achieved comparable results to the existing algorithms in the literature on the BIDMC dataset (containing data of 53 subjects, each recorded for 8 min) for other signal window sizes. Conclusion: The results endorse that integration of the proposed algorithm to a commercially available pulse oximetry device would expand its functionality from the measurement of oxygen saturation level and heart rate to the continuous measurement of the respiratory rate with good efficiency at home and in a clinical setting.

27 May 2019 in Journal of Alzheimer’s Disease
Verified
Journal Article
Open access
PDF file
MJMarggie Jones
Marggie Jones
BMBarry McDermott
Barry McDermott
BOBárbara Luz Oliveira
Bárbara Luz Oliveira
AOAoife O’BRien
Aoife O’BRien
DCDeclan Coogan
Declan Coogan
ASAtif Shahzad
Atif Shahzad
Background: It is known that proteins associated with Alzheimer’s disease (AD) pathogenesis are significantly reduced by 40 Hz entrainment in mice. If this were to translate to humans, verifying that such a light stimulus can induce a 40 Hz entrainment response in humans and harnessing insights from these case studies could be one step in the development of a multisensory device to prevent and treat AD. Objective: Verify the inducement of a 40 Hz response in the human brain by a 40 Hz light stimulus and obtain insights that could potentially aid in the development of a multisensory device for the prevention and treatment of AD. Methods: Electroencephalographic brain activity was recorded simultaneously with application of stimulus at different frequencies and intensities. Power spectral densities were analyzed. Results: Entrainment to visual stimuli occurred with the largest response at 40 Hz. The high intensity 40 Hz stimulus caused widespread entrainment. The number of electrodes demonstrating entrainment increased with increasing light intensity. Largest amplitudes for the high intensity 40 Hz stimulus were consistently found at the primary visual cortex. There was a harmonic effect at double the frequency for the 40 Hz stimulus. An eyes-open protocol caused more entrainment than an eyes-closed protocol. Conclusion: It was possible to induce widespread entrainment using a 40 Hz light stimulus in this sample cohort. Insights gleaned from these case studies could potentially aid in the development of a multisensory medical device to prevent and treat AD.

20 May 2021 in IEEE Access
Verified
Journal Article
Open access
Talha IqbalTalha Iqbal
Talha Iqbal
PRPau Redon-Lurbe
Pau Redon-Lurbe
ASAndrew J. Simpkin
Andrew J. Simpkin
AEAdnan Elahi
Adnan Elahi
SGSandra Ganly
Sandra Ganly
ASAtif Shahzad
Atif Shahzad
Stress is known as a silent killer that contributes to several life-threatening health conditions such as high blood pressure, heart disease, and diabetes. The current standard for stress evaluation is based on self-reported questionnaires and standardized stress scores. There is no gold standard to independently evaluate stress levels despite the availability of numerous biophysiological stress indicators. With an increasing interest in wearable health monitoring in recent years, several studies have explored the potential of various biophysiological indicators of stress for this purpose. However, there is no clear understanding of the relative sensitivity and specificity of these stress-related biophysiological indicators of stress in the literature. Hence this study aims to perform statistical analysis and classification modelling of biophysiological data gathered from healthy individuals, undergoing various induced emotional states, and to assess the relative sensitivity and specificity of common biophysiological indicators of stress. In this paper, several frequently used key indicators of stress, such as heart rate, respiratory rate, skin conductance, RR interval, heart rate variability in the electrocardiogram, and muscle activation measured by electromyography, are evaluated based on a detailed statistical analysis of the data gathered from an already existing, publicly available WESAD (Wearable Stress and Affect Detection) dataset. Respiratory rate and heart rate were the two best features for distinguishing between stressed and unstressed states.