This article reports a parametric study on the performance of a high aspect ratio, low speed contra-rotating fan stage. Parameters namely speed ratios of the two rotors and axial spacing between the rotors that play a significant role on the overall performance of the contra-rotating fan stage were evaluated. The rotors have a low hub-tip ratio of 0.35 and chord of 45 mm. The two rotors were designed to develop a pressure rise of 1100 Pa and 900 Pa, respectively, when operating at 2400 r/min and developing a mass flow rate of 6 kg/s. In order to evaluate the performance of the designed rotors, measurements of total pressure at the entry of rotor-1, between the rotors and the exit of rotor-2 were taken using total pressure probe rake, 4-hole probe and a Kiel probe rake. The experiments were conducted for different speed combinations of rotor-1 and rotor-2. All these speed combinations were studied separately for different axial spacing. The performance plots revealed the existence of two stall limits namely, partial stall and full stall. For lower throttle positions, rotor-2 was observed to stall. Further lowering the mass flow rate; reduces the pressure rise capacity of the stage due to stalling of rotor-1 as well as rotor-2. For the design speed operation of rotor-1 in combination with an off-design speed of rotor-2, the flow parameters change significantly. A higher rotational speed of rotor-2 generates a stronger suction effect leading to an overall improvement in the performance of the whole stage. The effect of variation in the axial spacing between the rotors was also studied. The strongest suction effect between the rotors was observed at an axial spacing of 0.9 chord.
An efficient and compact design of a compressor continues to be a challenging area of research. The unavoidable streamwise adverse pressure gradient together with passage transverse pressure gradient restricts the maximum allowable blade turning. Tandem blading is an interesting concept for increasing the pressure rise by permitting a higher blade turning angle. The energized flow through the tandem blade nozzle gap helps to minimize the possibility of flow separation over the suction surface of the aft blade. However, a coherent transient analysis of a tandem rotor stage in an axial compressor is yet to be well explored. In the present paper, the complex flow field over a tandem rotor and the succeeding stator passage is analyzed in detail. Although the tandem rotor increases the flow turning and diffusion effect, the presence of separate trailing edge wakes and hub corner vortex causes early onset of flow separation over the stator suction. The flow structures developed within the rotor and the stator passages at different time instances are highlighted with the help of limiting streamlines and iso-surface Q-criterion superimposed with entropy contours. The results indicate that within the rotor passage, transient flow features are observed near the hub corner region close to the aft blade trailing edge rather than the tip region. When the rotor passes the stator leading edge, the rotor trailing edge leakage flow at the hub is entrained into the stator leading edge reverse flow region. This is then further circumferentially dragged into the mid-passage region. The interference of multiple rotor wakes with the stator leading edge leads to the formation of longitudinal and arch like separation vortices at the stator-hub and the stator-casing regions, respectively. These separation vortices grow in size while being convected downstream. Eventually, as time progresses, the vortices split and shed periodically from the stator surface. The present investigation highlights the requirement of a new stator design in a tandem rotor–conventional stator configuration. Such designs could further magnify the significant aerodynamic performance obtained using a tandem configuration.
The aerodynamic stability of an axial compressor stage depends on the rotor and stator. However, due to the specific design requirements, the evolving flow field and the resulting secondary flow structures are different in both components. This study investigates the evolution of dominant secondary flow structures occurring in the rotor and stator of a tip-critical transonic compressor stage at the near-stall condition using unsteady numerical analysis and validates performance characteristics with the experimental data. The investigation reveals that the presence of rotor tip shock creates a large difference in the pressure gradient across the pressure surface and the suction surface, intensifying tip leakage flow and shock-induced boundary layer separation. The higher incidence angle near the hub leading edge creates a local separation and reattachment zone. The radial pressure gradient causes the low momentum flow from this local separation zone to migrate radially upward. This migrated flow interacts with the tip leakage flow and separated blade boundary layer, eventually creating a colossal recirculation zone and subsequent rotor blockage of around 46%. The increasing streamwise adverse pressure gradient pushes the tip shock upstream, and at the onset of the stall, the flow directly separates from the rotor leading edge avoiding the shock formation. The stator flow field is dominated by the asymmetric hub corner separation induced by the streamwise adverse pressure gradient and the tip corner separation caused by the vortex structures convected downstream from the rotor tip region leading to stator blockage of around 48%. Along with the blade passing frequency, four other dominating frequencies (0.06×BPF, 0.12×BPF, 0.44×BPF, and 0.84×BPF) related to the aerodynamic instabilities are observed at the inception of stall.
The influence of circumferential inflow distorted on the performance and flow behavior of a high aspect ratio, low speed contra rotating fan is reported in this paper. The total pressure at the inlet is artificially distorted by means of 90 deg mesh sector with a porosity of 0.70. The performance of the contra rotating fan was studied under different speed combinations of the two rotors under clean and distorted inflow conditions. Detailed flow analyses were conducted under design and off-design conditions. In order to understand the effect of distortion and its extent, the distortion sector was rotated circumferentially at intervals of 15 deg to cover the entire annulus. Detailed measurements of the total pressure, velocity components, and flow angles were carried out at the inlet of the first rotor, between the two rotors, and at the exit of the second rotor. The study reveals a few interesting aspects on the effect of inflow distortion on the performance of a contra-rotating stage. For the design speed combination and lower rotational speed of rotor-2, a reduction in the overall operating range with a shift of the peak pressure point towards higher mass flow rate, was observed. It is observed that the effect of inflow distortion at the inlet of rotor-1 gets transferred in the direction of rotor-1 rotation and spreads across the entire annulus. The opposite sense of rotation of rotor-2 causes the distortion effect to get transferred in the direction of rotation of rotor-2 with an associated reduction in the total pressure near the hub. It is observed that a higher rotational speed of the second rotor has a beneficial effect on the overall performance due to the strong suction by generated higher rotational speed of rotor-2.
The present paper describes the use of Morlet wavelet transform in understanding the stall inception mechanism in a single stage axial flow fan. Unsteady pressure data from wall mounted sensors were used in the wavelet transforms. This paper was carried out under undistorted and distorted inflow conditions as well as for slow throttle closure and throttle ramping. It was observed from the wavelet transforms that the stall inception under clean inflow (undistorted) and counter-rotating inflow distortions (in the direction opposing the rotor rotation) incur through short length-scale disturbances and through long length-scale disturbances under static and co-rotating inflow distortions (in the same direction of rotor rotation). Modal activity was observed to be insignificant under clean inflow while under static inflow distortion, long length-scale disturbances evolved due to interaction between rotor blades and the distorted sector, especially near the trailing edge of the distortion screen. The presence of a strong mode was observed under both co- and counter-rotating inflow distortions. With throttle ramping, stall inception occurs through long and short length-scale disturbances under co- and counter-rotating inflow distortions, respectively. Some preliminary flow characteristics were studied using a seven hole probe. A significant increase in flow angle and decrease in axial flow coefficient close to the rotor tip were observed under co-rotating inflow distortion as compared with counter-rotating inflow distortion.