Background: To determine whether a proximal tibiofibular joint dislocation (TFJD) increases lateral compartment gapping more than a fibular head osteotomy (FHO) during a closing-wedge high tibial osteotomy (CWHTO). The second objective was to determine whether lateral compartment gapping affects clinical outcomes. Methods: A prospective randomized clinical study was carried out that included 18 patients in Group 1 (FHO) and 18 in Group 2 (TFJD). Varus-stress radiographs of all the patients with both knees at full extension and at 30° of flexion were studied pre-operatively and 12 months post-operatively. Lateral compartment gapping was measured in millimeters. The Knee Society Score (KSS) was used to assess clinical stability. Results: The difference between the pre- and post-operative measurements relative to gapping in the lateral knee compartment at 0° of knee flexion was 1.3 mm (SD 1.8) in Group 1 and 4.5 mm (SD 2.4) in Group 2 (p = 0.006). At 30° of knee flexion, this difference was 1.9 mm (SD 1.2) in Group 1 and 5.2 mm (SD 3.1) in Group 2 (p = 0.01). No differences were observed in the pre- and post-operative period relative to gapping in healthy knees. Pre-operatively, both groups presented similar KSS knee values: Group 1 with 54.7 (SD 11.7), Group 2 with 54.8 (SD 11.1) (n.s.). Post-operatively, these values were also similar: Group 1 with 93.2 (SD 7.4), Group 2 with 93.5 (SD 5.5) (n.s.). Conclusions: In patients who have undergone a CWHTO, TFJ dislocation increases knee lateral compartment gapping when compared to an FHO at 0° and 30° of knee flexion. However, this fact seems to have no repercussion on the functional status of the knees as measured with the KSS at the one-year follow-up.
Background: Total knee arthroplasty (TKA) has become the gold standard for the definitive treatment of knee osteoarthritis. One crucial aspect in the implantation of a TKA is the precise orientation of the femoral and tibial components. The main purpose of the present study is to assess, in patients undergoing total knee replacement, whether the difference between the planned angulation in the distal femoral cut and the angulation obtained in the postoperative radiological control is low enough to consider the conventional bone-cutting guides reliable. Methods: A retrospective study was designed with a consecutive series of patients who had undergone primary total knee arthroplasty using conventional instrumentation over one year. The authors analysed the main variable (bone cuts) while considering different variables (age, gender, surgeon, prosthesis, laterality, constraint, body mass index and alignment) to identify different patient patterns that justify the results in the main variable. Descriptive variables were analysed using the Mann–Whitney U and Kruskal–Wallis tests. Additionally, the correlation between continuous variables was explored in accordance with the Spearman correlation. Results: A total of 340 patients with a mean age of 75 ± 9.16 years were finally included in the present study. The mean absolute error of the main variable for the femoral coronal bone cut was 1.89° (SD 1.53). For the tibial coronal bone cut, it was 1.31° (SD 2.54). These values correspond to what remains after subtracting the radiological angulation obtained in the postoperative period from the planned intraoperative angulation of the distal femoral cut. No associations were observed between the main variable (the angulation of the proximal tibial cut and distal femoral cut) and the rest of variables for either the femur or tibia. Conclusion: A discrepancy between the planned angulation and the final radiological measure on the coronal plane of the femur and tibia using conventional cutting guides has been demonstrated. The degree of deviation is low enough that it probably does not affect clinical outcomes. Therefore, the use of conventional cutting guides will continue to be an appropriate tool to perform bone cuts in knee replacement surgery.
29 December 2022 in Journal of Experimental Orthopaedics
Purpose: The objective of this study was to evaluate the effects on the posterior tibial slope of different distances from the joint line to start the osteotomy and of varying the placement of the opening wedge in high tibial osteotomy.Starting the osteotomy more distally and an incorrect location for the tibial opening wedge were hypothesized to increase the posterior tibial slope.Methods: A cadaveric study was conducted using 12 knees divided into two groups based on the distance from the joint line to the start of the osteotomy: 3 and 4 cm. The preintervention posterior tibial slope was measured radiologically. Once the osteotomy was performed, the medial cortex of the tibia was divided into anteromedial, medial, and posteromedial thirds. A 10° opening wedge was sequentially placed in each third, and the effect on the posterior tibial slope was evaluated radiographically.Results: Significant changes were observed only in the 3‐cm group (p = 0.02) when the wedge was placed in the anteromedial zone. In contrast, in the 4‐cm group, significant differences were observed when the opening wedge was placed at both the medial (p = 0.04) and anteromedial (p = 0.012) zones.Conclusion: Correct control of the posterior tibial slope can be achieved by avoiding a low point when beginning the osteotomy and placing the opening wedge in the posteromedial third of the tibia when performing an opening‐wedge high tibial osteotomy.Level of evidence: Controlled laboratory study.
Purpose: Intraoperative extension deficiency (IED) following trial implantation in total knee arthroplasty (TKA) must be distinguished from preoperative fixed flexion contracture (FFC). Its optimal management remains poorly quantified and likely depends on patient-specific biomechanical and geometric factors. This study aimed to quantify the mechanical contribution of posterior capsule release (PCR), posterior cruciate ligament (PCL) excision, and incremental distal femoral resection using robotic-assisted measurement, and to develop a predictive model incorporating deformity and femoral geometry. Materials and Methods: A two-phase study was performed. A cadaveric robotic-assisted TKA model (29 knees) assessed sequential effects of PCR, PCL excision, and distal femoral resection on extension and laxity. A prospective clinical cohort of 195 robotic-assisted TKAs with IED was then analyzed to validate biomechanical relationships in vivo. A multivariable regression model was constructed to estimate the effect of distal femoral resection on extension correction, incorporating flexion contracture coronal alignment, implant positioning, and femoral size as a geometric scaling factor. Results: In the cadaveric model, PCR corrected IED in 36.8% of cases (1.68° ± 1.11°). Distal femoral resection produced 4.3°/mm with an intact PCL and 2.8°/mm after PCL excision. PCL excision alone provided minimal correction (1.1° ± 1.3°). Larger femoral morphology reduced angular gain per millimeter of resection, consistent with geometric scaling effects. In the clinical cohort, distal femoral resection showed a mean effect of 5.8°/mm but demonstrated marked inter-patient variability. Correction sensitivity increased with native flexion contracture (+0.72°/mm per degree) and varus alignment (+0.1°/mm per degree), while femoral size reduced angular response. PCL status was not significant. Conclusions: Distal femoral resection is the dominant factor in correcting IED, but its effect is not fixed. It is modulated by deformity severity and femoral geometry, particularly size-dependent scaling of the femorotibial radius. These findings support a nonlinear, patient-specific mechanical model of extension correction and provide a basis for predictive intraoperative decision-making in TKA.