Hyoki Lee

Dr. Hyoki Lee

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2018 in Occupational and Environmental Medicine
Verified
Journal Article
Open access
PDF file
CLCasey M Lindberg
Casey M Lindberg
KSKarthik Srinivasan
Karthik Srinivasan
BGBrian Gilligan
Brian Gilligan
JRJavad Razjouyan
Javad Razjouyan
HLHyoki Lee
Hyoki Lee
ESEsther M. Sternberg
Esther M. Sternberg
Objective Office environments have been causally linked to workplace-related illnesses and stress, yet little is known about how office workstation type is linked to objective metrics of physical activity and stress. We aimed to explore these associations among office workers in US federal office buildings. Methods We conducted a wearable, sensor-based, observational study of 231 workers in four office buildings. Outcome variables included workers’ physiological stress response, physical activity and perceived stress. Relationships between office workstation type and these variables were assessed using structural equation modelling. Results Workers in open bench seating were more active at the office than those in private offices and cubicles (open bench seating vs private office=225.52 mG (31.83% higher on average) (95% CI 136.57 to 314.46); open bench seating vs cubicle=185.13 mG (20.16% higher on average) (95% CI 66.53 to 303.72)). Furthermore, workers in open bench seating experienced lower perceived stress at the office than those in cubicles (−0.27 (9.10% lower on average) (95% CI −0.54 to −0.02)). Finally, higher physical activity at the office was related to lower physiological stress (higher heart rate variability in the time domain) outside the office (−26.12 ms/mG (14.18% higher on average) (95% CI −40.48 to −4.16)). Conclusions Office workstation type was related to enhanced physical activity and reduced physiological and perceived stress. This research highlights how office design, driven by office workstation type, could be a health-promoting factor.

9 November 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HLHyoki Lee
Hyoki Lee
HCH. Chung
H. Chung
Jinseok LeeJinseok Lee
Jinseok Lee
Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for exercise involving walking.

15 November 2017 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
JRJavad Razjouyan
Javad Razjouyan
HLHyoki Lee
Hyoki Lee
SPSairam Parthasarathy
Sairam Parthasarathy
JMJane Mohler
Jane Mohler
ASAmir Sharafkhaneh
Amir Sharafkhaneh
Bijan NajafiBijan Najafi
Bijan Najafi
Study Objectives:To improve sleep quality assessment using a single chest-worn sensor by extracting body acceleration and sleep position changes.Methods:Sleep patterns of 21 participants (50.8 ± 12...

25 November 2017 in Gerontology
Verified
Journal Article
Closed access
PDF file
HLHyoki Lee
Hyoki Lee
BJBellal Joseph
Bellal Joseph
AEAna Enriquez
Ana Enriquez
Bijan NajafiBijan Najafi
Bijan Najafi
Background: While various objective tools have been validated for assessing physical frailty in the geriatric population, these are often unsuitable for busy clinics and mobility-impaired patients. Recently, we have developed a frailty meter (FM) using two wearable sensors, which allows capturing key frailty phenotypes (weakness, slowness, and exhaustion), by testing 20-s rapid elbow flexion-extension test. Objective: In this study, we proposed an enhanced automated algorithm to identify frailty using a single wrist-worn sensor. Methods: The data collected from 100 geriatric inpatients (age: 78.9 ± 9.1 years, 49% frail) were reanalyzed to validate the new algorithm. The frailty status of the participants was determined using a validated modified frailty index. Different FM phenotypes (31 features) including velocity of elbow rotation, decline in velocity of elbow rotation over 20 s, range of motion, etc. were extracted. A regression model, bootstrap with 2,000 iterations, and recursive feature elimination technique were used for optimizing the FM parameters and identifying frailty using a single wrist-worn sensor. Results: A strong agreement was observed between two-sensor and wrist-worn sensor configuration (r = 0.87, p < 0.001). Results suggest that the wrist-worn FM with no demographic information still yields a high accuracy of 80.0% (95% CI: 79.7-80.3%) and an area under the curve of 87.7% (95% CI: 87.4-87.9%) to identify frailty status. Results are comparable with two-sensor configuration, where the observed accuracy and area under the curve were 80.6% (95% CI: 80.4-80.9%) and 87.4% (95% CI: 87.1-87.6%), respectively. Conclusion: The simplicity of FM may open new avenues to integrate wearable technology and mobile health to capture frailty status in a busy hospital setting. Furthermore, the reduction of needed sensors to a single wrist-worn sensor allows deployment of the proposed algorithm in the form of a smartwatch application. From the application standpoint, the proposed FM is superior to traditional physical frailty-screening tools in which the walking test is a key frailty phenotype, and thus they cannot be used for bedbound patients or in busy clinics where administration of gait test as a part of routine assessment is impractical.

27 October 2016 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
HLHyoki Lee
Hyoki Lee
JPJonguk Park
Jonguk Park
HKHojoong Kim
Hojoong Kim
KLKyoung-Joung Lee
Kyoung-Joung Lee

20 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
HZHe Zhou
He Zhou
HLHyoki Lee
Hyoki Lee
JLJessica Lee
Jessica Lee
MSMichael Schwenk
Michael Schwenk
Bijan NajafiBijan Najafi
Bijan Najafi
Practical tools which can be quickly administered are needed for measuring subtle changes in cognitive–motor performance over time. Frailty together with cognitive impairment, or ‘cognitive frailty’, are shown to be strong and independent predictors of cognitive decline over time. We have developed an interactive instrumented trail-making task (iTMT) platform, which allows quantification of motor planning error (MPE) through a series of ankle reaching tasks. In this study, we examined the accuracy of MPE in identifying cognitive frailty in older adults. Thirty-two older adults (age = 77.3 ± 9.1 years, body-mass-index = 25.3 ± 4.7 kg/m2, female = 38%) were recruited. Using either the Mini-Mental State Examination or Montreal Cognitive Assessment (MoCA), 16 subjects were classified as cognitive-intact and 16 were classified as cognitive-impaired. In addition, 12 young-healthy subjects (age = 26.0 ± 5.2 years, body-mass-index = 25.3 ± 3.9 kg/m2, female = 33%) were recruited to establish a healthy benchmark. Subjects completed the iTMT, using an ankle-worn sensor, which transforms ankle motion into navigation of a computer cursor. The iTMT task included reaching five indexed target circles (including numbers 1-to-3 and letters A&B placed in random order) on the computer-screen by moving the ankle-joint while standing. The ankle-sensor quantifies MPE through analysis of the pattern of ankle velocity. MPE was defined as percentage of time deviation between subject’s maximum ankle velocity and the optimal maximum ankle velocity, which is halfway through the reaching pathway. Data from gait tests, including single task and dual task walking, were also collected to determine cognitive–motor performance. The average MPE in young-healthy, elderly cognitive-intact, and elderly cognitive-impaired groups was 11.1 ± 5.7%, 20.3 ± 9.6%, and 34.1 ± 4.2% (p < 0.001), respectively. Large effect sizes (Cohen’s d = 1.17–4.56) were observed for discriminating between groups using MPE. Significant correlations were observed between the MPE and MoCA score (r = −0.670, p < 0.001) as well as between the MPE and dual task stride velocity (r = −0.584, p < 0.001). This study demonstrated feasibility and efficacy of estimating MPE from a practical wearable platform with promising results in identifying cognitive–motor impairment and potential application in assessing cognitive frailty. The proposed platform could be also used as an alternative to dual task walking test, where gait assessment may not be practical. Future studies need to confirm these observations in larger samples.