Zhongmin Jin

Dr. Zhongmin Jin

School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2006 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
Zhongmin JinZhongmin Jin
Zhongmin Jin
SMS Meakins
S Meakins
MMMichael Morlock
Michael Morlock
PPP Parsons
P Parsons
CHC Hardaker
C Hardaker
GIG Isaac
G Isaac
The interference press fit of a metallic one-piece acetabular cup employed for metal-on-metal hip resurfacing procedures was investigated experimentally under laboratory conditions in the present study, in particular regarding the cup deformation. Tests were carried out in cadavers as well as polyurethane foams of various grades with different elastic moduli to represent different cancellous bone qualities. The cadaver test was used to establish the most suitable configuration of the foam model representing realistic support and geometrical conditions at the pelvis. It was found that a spherical cavity, with two identical areas relieved on opposite sides, was capable of creating a two-point pinching action of the ischeal and ilial columns on the cup as the worst-case scenario. Furthermore, the cup deformation produced from such a two-point loading model with a grade 30 foam was similar to that measured from the cadaver test. Therefore, such a protocol was employed in subsequent experimental tests. For a given size of the outside diameter of the cup of 60 mm, the cup deflection was shown to be dependent largely on the cup wall thickness and the diametral interference between cup and prepared cavity at implantation. For a relatively thin cup with a wall thickness between 2.3 mm (equator) and 4 mm (pole) and with a modest nominal diametral interference of 1 mm, which corresponds to an actual interference of approximately 0.5 mm, the maximum diametral cup deflection (at the rim) was around 60 μm, compared with a diametral clearance of 80-120 μm between the femoral head and the acetabular cup, generally required for fluid-film lubrication and tribological performances. Stiffening of the cup, by both thickening and lateralizing by 1 mm, reduced the cup deformation to between 30 and 50 μm with actual diametral interferences between 0.5 and 1 mm.

13 June 2013 in Friction
Verified
Journal Article
Open access
PDF file
Zhongmin JinZhongmin Jin
Zhongmin Jin
DDDuncan Dowson
Duncan Dowson
Friction studies in biological systems are reviewed, including synovial joints (cartilage, meniscus), eye, pleurae, fat pad, skin, and oral cavity as well as daily activities associated with shaving, brushing, slip, etc. Both natural systems and medical interventions in terms of diagnoses and artificial replacements are considered. Important relevant biomechanical, physiological, and anatomical factors are reviewed in conjunction with friction studies in terms of both methodologies and friction coefficients. Important underlying tribological mechanisms related to friction are briefly discussed. A unified view on the lubrication mechanism responsible for the low friction in most soft biological tissues is presented.

9 June 2021 in Friction
Verified
Journal Article
Open access
PDF file
XZXiaogang Zhang
Xiaogang Zhang
YZYali Zhang
Yali Zhang
Zhongmin JinZhongmin Jin
Zhongmin Jin
Numerous medical devices have been applied for the treatment or alleviation of various diseases. Tribological issues widely exist in those medical devices and play vital roles in determining their performance and service life. In this review, the bio-tribological issues involved in commonly used medical devices are identified, including artificial joints, fracture fixation devices, skin-related devices, dental restoration devices, cardiovascular devices, and surgical instruments. The current understanding of the bio-tribological behavior and mechanism involved in those devices is summarized. Recent advances in the improvement of tribological properties are examined. Challenges and future developments for the prospective of bio-tribological performance are highlighted.

12 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
FZFeng Zhao
Feng Zhao
DLDichen Li
Dichen Li
Zhongmin JinZhongmin Jin
Zhongmin Jin
Poly-ether-ether-ketone (PEEK) fabricated by fused deposition modeling for medical applications was evaluated in terms of mechanical strength and in vitro cytotoxicity in this study. Orthogonal experiments were firstly designed to investigate the significant factors on tensile strength. Nozzle temperature, platform temperature, and the filament diameter were tightly controlled for improved mechanical strength performance. These sensitive parameters affected the interlayer bonding and solid condition in the samples. Fourier transform infrared (FTIR) spectrometry analysis was secondly conducted to compare the functional groups in PEEK granules, filaments, and printed parts. In vitro cytotoxicity test was carried out at last, and no toxic substances were introduced during the printing process.

YPYinghu Peng
Yinghu Peng
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
YWYan Wang
Yan Wang
TCTony Lin-Wei Chen
Tony Lin-Wei Chen
QTQitao TAN
Qitao TAN
MZMing Zhang
Ming Zhang
Flatfoot is linked to secondary lower limb joint problems, such as patellofemoral pain. This study aimed to investigate the influence of medial posting insoles on the joint mechanics of the lower extremity in adults with flatfoot. Gait analysis was performed on fifteen young adults with flatfoot under two conditions: walking with shoes and foot orthoses (WSFO), and walking with shoes (WS) in random order. The data collected by a vicon system were used to drive the musculoskeletal model to estimate the hip, patellofemoral, ankle, medial and lateral tibiofemoral joint contact forces. The joint contact forces in WSFO and WS conditions were compared. Compared to the WS group, the second peak patellofemoral contact force (p < 0.05) and the peak ankle contact force (p < 0.05) were significantly lower in the WSFO group by 10.2% and 6.8%, respectively. The foot orthosis significantly reduced the peak ankle eversion angle (p < 0.05) and ankle eversion moment (p < 0.05); however, the peak knee adduction moment increased (p < 0.05). The reduction in the patellofemoral joint force and ankle contact force could potentially inhibit flatfoot-induced lower limb joint problems, despite a greater knee adduction moment.

4 March 2019 in Rapid Prototyping Journal
Verified
Journal Article
Closed access
XWXiangquan Wu
Xiangquan Wu
QLQin Lian
Qin Lian
DLDichen Li
Dichen Li
Zhongmin JinZhongmin Jin
Zhongmin Jin
Purpose: This study aims to develop a multi-material stereolithography (MMSL) technique to directly fabricate a biphasic osteochondral scaffold. Design/methodology/approach: A bespoke prototype MMSL system was developed based on a bottom-up mask projection approach. The system was controlled by a multi-material fabrication algorithm with minimum number of switching cycles during fabrication. A variable-power light source was used to fabricate materials with significantly different curing characteristics. The light-curable poly(ethylene glycol) diacrylate (PEGDA) hydrogel and beta-tricalcium phosphate (β-TCP) ceramic suspension were used for fabricating the biphasic osteochondral scaffold. Findings: The bonding strength of the multi-material interface is shown to be mainly affected by the type of photopolymer, rather than the switching of the materials in MMSL. Lighting power densities of 2.64 and 14.98 mW/cm2 were used for curing the PEGDA hydrogel and the ß-TCP ceramic suspension, respectively. A biphasic osteochondral scaffold with complex interface was successfully fabricated. Originality/value: This study proposes a potential technical method (MMSL) for manufacturing a complex biphasic osteochondral scaffold composing a PEGDA hydrogel/ß-TCP ceramic composite in a time-efficient and precise manner. The designed bone-cartilage scaffold interface and the surface of the cartilage scaffold can be precisely manufactured.