Michael Morlock

Prof. Dr. Michael Morlock

orcid

Research Focus & Metrics

Academic Career Length

77Years (1950-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2008 in Journal of Biomechanics
Verified
Journal Article
Closed access
MWMarkus Windolf
Markus Windolf
NGNils Götzen
Nils Götzen
MMMichael Morlock
Michael Morlock

1 July 2001 in Journal of Biomechanics
Verified
Journal Article
Closed access
MMMichael Morlock
Michael Morlock
ESE Schneider
E Schneider
ABA Bluhm
A Bluhm
MVM Vollmer
M Vollmer
GBG Bergmann
G Bergmann
MHM Honl
M Honl

1 August 2008 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MMMichael Morlock
Michael Morlock
NBNick Bishop
Nick Bishop
JZJozef Zustin
Jozef Zustin
MHMichael Hahn
Michael Hahn
WRWolfgang Rüther
Wolfgang Rüther
MAMichael Amling
Michael Amling
Resurfacing implants in order to understand failure mechanisms....

1 January 2010 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
GBG. Bergmann
G. Bergmann
FGF. Graichen
F. Graichen
ARA. Rohlmann
A. Rohlmann
ABA. Bender
A. Bender
BHB. Heinlein
B. Heinlein
MMMichael Morlock
Michael Morlock
The aim here was to define realistic load conditions for hip implants, based on in vivo contact force measurements, and to see whether current ISO standards indeed simulate real loads. The load scenarios obtained are based on in vivo hip contact forces measured in 4 patients during different activities and on activity records from 31 patients. The load scenarios can be adapted to various test purposes by applying average or high peak loads, high-impact activities or additional low-impact activities, and by simulating normal or very active patients. The most strenuous activities are walking (average peak forces 1800 N, high peak forces 3900 N), going up stairs (average peak forces 1900 N, high peak forces 4200 N) and stumbling (high peak forces 11,000 N). Torsional moments are 50% higher for going up stairs than for walking. Ten million loading cycles simulate an implantation time of 3.9 years in active patients. The in vitro fatigue properties of cementless implant fixations are exceeded during stumbling. At least for heavyweight and very active subjects, the real load conditions are more critical than those defined by the ISO standards for fatigue tests.

28 April 2010 in Materials
Verified
Journal Article
Open access
PDF file
MMMeenakshi Mour
Meenakshi Mour
DDDebarun Das
Debarun Das
TWThomas Winkler
Thomas Winkler
EHElisa Hoenig
Elisa Hoenig
GMGabriela Mielke
Gabriela Mielke
ASArndt F. Schilling
Arndt F. Schilling
The connective hard tissues bone and teeth are highly porous on a micrometer scale, but show high values of compression strength at a relatively low weight. The fabrication of porous materials has been actively researched and different processes have been developed that vary in preparation complexity and also in the type of porous material that they produce. Methodologies are available for determination of pore properties. The purpose of the paper is to give an overview of these methods, the role of porosity in natural porous materials and the effect of pore properties on the living tissues. The minimum pore size required to allow the ingrowth of mineralized tissue seems to be in the order of 50 µm: larger pore sizes seem to improve speed and depth of penetration of mineralized tissues into the biomaterial, but on the other hand impair the mechanical properties. The optimal pore size is therefore dependent on the application and the used material.

8 April 2017 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
LWLukas Weiser
Lukas Weiser
GHGerd Huber
Gerd Huber
KSKay Sellenschloh
Kay Sellenschloh
LVLennart Viezens
Lennart Viezens
KPKlaus Püschel
Klaus Püschel
WLWolfgang Lehmann
Wolfgang Lehmann