Nina Verdel

Dr. Nina Verdel

Jozef Stefan Institute
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NVNina Verdel
Nina Verdel
TPTim Podlogar
Tim Podlogar
UCUrša Ciuha
Urša Ciuha
HHHans-Christer Holmberg
Hans-Christer Holmberg
TDTadej Debevec
Tadej Debevec
Matej SupejMatej Supej
Matej Supej
Monitoring core body temperature (Tc) during training and competitions, especially in a hot environment, can help enhance an athlete’s performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of Tc would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rümlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 °C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 °C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (Trec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 °C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with Trec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of ≤0.3 °C. In conclusion, the results obtained do not support the manufacturer’s claim that the CORE sensor provides a valid measure of core body temperature.

29 January 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
NVNina Verdel
Nina Verdel
AMAna Marin
Ana Marin
Matija MilanicMatija Milanic
Matija Milanic
Boris MajaronBoris Majaron
Boris Majaron
In this proof-of-concept study we combine two optical techniques to enable assessment of structure and composition of human skin in vivo: Pulsed photothermal radiometry (PPTR), which involves measurements of transient dynamics in mid-infrared emission from sample surface after exposure to a light pulse, and diffuse reflectance spectroscopy (DRS) in visible part of the spectrum. The analysis involves simultaneous fitting of measured PPTR signals and DRS with corresponding predictions of a Monte Carlo model of light-tissue interaction. By using a four-layer optical model of skin we obtain a good match between the experimental and model data when scattering properties of the epidermis and dermis are also optimized on an individual basis. The assessed parameter values correlate well with literature data and demonstrate the expected trends in controlled tests involving temporary obstruction of peripheral blood circulation using a pressure cuff, and acute as well as seasonal sun tanning.

30 March 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
RDR. Dolenec
R. Dolenec
SKS. Korpar
S. Korpar
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
NVNina Verdel
Nina Verdel
Silicon photomultipliers (SiPMs) were considered as photodetectors in Cherenkov time-of-flight positron emission tomography (TOF PET) due to their relatively high photon detection efficiency (PDE) which resulted in a higher gamma detection efficiency of the Cherenkov PET detector. SiPMs produced by KETEK, AdvanSiD, SensL and Hamamatsu were tested in this application. The coincidence time resolution, gamma detection efficiency and single side event rates were measured in a simple experimental setup, consisting of two detectors placed in a coincidence configuration. The apparatus was cooled to -25° C in order to reduce the SiPM dark count rates. A single side gamma detection efficiency of up to 26% was measured, which is a marked improvement over previous Cherenkov TOF PET measurements. The best measured coincidence time resolution of 297 ps FWHM was limited by the time response of the SiPMs used for this experiments.

19 April 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
NVNina Verdel
Nina Verdel
GLGriffin Lentsch
Griffin Lentsch
MBMihaela Balu
Mihaela Balu
BTBruce J. Tromberg
Bruce J. Tromberg
Boris MajaronBoris Majaron
Boris Majaron
We are combining two optical techniques, pulsed photothermal radiometry (PPTR) and diffuse reflectance spectroscopy (DRS), for noninvasive assessment of the structure and composition of human skin in vivo. The analysis involves simultaneous multidimensional fitting of the measured PPTR signals and DRS spectra with predictions of a numerical model of light transport (Monte Carlo) in a four-layer model optical model of human skin, accounting for the epidermis, papillary and reticular dermis, and subcutis. The assessed epidermal thickness values were tested by coregistration with a multiphoton microscope, which provides vertical sectioning capability based on two-photon excited fluorescence and second-harmonic generation in selected skin components. The comparison shows that these values correspond well to the maximal epidermal thicknesses measured in the multiphoton microscopy images, the rete ridges.

28 February 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
NVNina Verdel
Nina Verdel
JTJovan Tanevski
Jovan Tanevski
SDSašo Džeroski
Sašo Džeroski
Boris MajaronBoris Majaron
Boris Majaron
We have recently introduced a novel methodology for the noninvasive analysis of the structure and composition of human skin in vivo. The approach combines pulsed photothermal radiometry (PPTR), involving time-resolved measurements of mid-infrared emission after irradiation with a millisecond light pulse, and diffuse reflectance spectroscopy (DRS) in the visible part of the spectrum. Simultaneous fitting of both data sets with respective predictions from a numerical model of light transport in human skin enables the assessment of the contents of skin chromophores (melanin, oxy-, and deoxy-hemoglobin), as well as scattering properties and thicknesses of the epidermis and dermis. However, the involved iterative optimization of 14 skin model parameters using a numerical forward model (i.e., inverse Monte Carlo - IMC) is computationally very expensive. In order to overcome this drawback, we have constructed a very fast predictive model (PM) based on machine learning. The PM involves random forests, trained on ∼9,000 examples computed using our forward MC model. We show that the performance of such a PM is very satisfying, both in objective testing using cross-validation and in direct comparisons with the IMC procedure. We also present a hybrid approach (HA), which combines the speed of the PM with versatility of the IMC procedure. Compared with the latter, the HA improves both the accuracy and robustness of the inverse analysis, while significantly reducing the computation times.

5 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AMAna Marin
Ana Marin
NVNina Verdel
Nina Verdel
Matija MilanicMatija Milanic
Matija Milanic
Boris MajaronBoris Majaron
Boris Majaron
We have augmented a recently introduced method for noninvasive analysis of skin structure and composition and applied it to monitoring of dynamical processes in traumatic bruises. The approach combines diffuse reflectance spectroscopy in visible spectral range and pulsed photothermal radiometry. Data from both techniques are analyzed simultaneously using a numerical model of light and heat transport in a four-layer model of human skin. Compared to the earlier presented approach, the newly introduced elements include two additional chromophores (β-carotene and bilirubin), individually adjusted thickness of the papillary dermal layer, and analysis of the bruised site using baseline values assessed from intact skin in its vicinity. Analyses of traumatic bruises in three volunteers over a period of 16 days clearly indicate a gradual, yet substantial increase of the dermal blood content and reduction of its oxygenation level in the first days after injury. This is followed by the emergence of bilirubin and relaxation of all model parameters towards the values characteristic for healthy skin approximately two weeks after the injury. The assessed parameter values and time dependences are consistent with existing literature. Thus, the presented methodology offers a viable approach for objective characterization of the bruise healing process.