Rok Dolenec

Rok Dolenec

Auto-generated profile, based on publicly available information

Rok Dolenec

Jozef Stefan Institute

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
RDR. Dolenec
R. Dolenec
SKS. Korpar
S. Korpar
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
NVNina Verdel
Nina Verdel
Silicon photomultipliers (SiPMs) were considered as photodetectors in Cherenkov time-of-flight positron emission tomography (TOF PET) due to their relatively high photon detection efficiency (PDE) which resulted in a higher gamma detection efficiency of the Cherenkov PET detector. SiPMs produced by KETEK, AdvanSiD, SensL and Hamamatsu were tested in this application. The coincidence time resolution, gamma detection efficiency and single side event rates were measured in a simple experimental setup, consisting of two detectors placed in a coincidence configuration. The apparatus was cooled to -25° C in order to reduce the SiPM dark count rates. A single side gamma detection efficiency of up to 26% was measured, which is a marked improvement over previous Cherenkov TOF PET measurements. The best measured coincidence time resolution of 297 ps FWHM was limited by the time response of the SiPMs used for this experiments.

27 September 2021 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
GRGasper Razdevsek
Gasper Razdevsek
RDRok Dolenec
Rok Dolenec
PKPeter Krizan
Peter Krizan
SMStan Majewski
Stan Majewski
ASAndrej Studen
Andrej Studen
RPRok Pestotnik
Rok Pestotnik
In this simulation study, we evaluate the performance of a limited angular coverage PET system consisting of two/four fast-timing 50 ps FWHM CTR flat-panel detectors made of 5–20 mm long pixelated lutetium oxyorthosilicate crystals. We studied image quality and count rates following the National Electrical Manufacturers Association standard, spatial resolution by imaging a Derenzo phantom and a hot rod, and investigated the sensitivity of different scanner designs. We demonstrated the possible use of such a scanner by imaging a human head and a torso of the extended cardiac-torso (XCAT) digital phantom. All the designs were compared to the reference scanner, based on Siemens Biograph Vision PET/CT scanner geometry. We show that good coincidence timing resolution (CTR) can compensate for lower detection efficiency or smaller angular coverage. Good image quality can be obtained with a simple limited-angle PET system without distortions or artefacts. Substantial degradation of the spatial resolution with increased crystal length is observed in the two-panel design due to the parallax error, but not in the four-panel design. The four-panel design simulated with a CTR of 50 ps FWHM is comparable to that of the current state-of-the-art clinical PET/CT scanner. Similar fast-timing limited-angle planar detectors could enable much less expensive total-body or single organ (dynamically selectable) imaging devices.

8 July 2010 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SSSusumu Shiizuka
Susumu Shiizuka
IAIchiro Adachi
Ichiro Adachi
RDRok Dolenec
Rok Dolenec
KHKoji Hara
Koji Hara
TIToru Iijima
Toru Iijima
RTRie Tagai
Rie Tagai

1 January 2012 in Physics Procedia
Verified
Journal Article
Open access
SKS. Korpar
S. Korpar
RDR. Dolenec
R. Dolenec
PKPeter Križan
Peter Križan
RPRok Pestotnik
Rok Pestotnik
ASA. Stanovnik
A. Stanovnik
We report on measurements of coincident 511 keV annihilation photons via detection of Cherenkov radiation in PbF2 crystals attached to a microchannel plate photomultiplier. Back to back timing resolution has been studied with segmented crystals. The detection efficiency has also been measured and compared to the simulation results. We have also searched for the optimum radiator parameters by simulating timing resolution and effciency as a function of crystal thickness and transmission cut-off

26 August 2022 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
GRG. Razdevsek
G. Razdevsek
RPRok Pestotnik
Rok Pestotnik
PKP. Krizan
P. Krizan
SKS. Korpar
S. Korpar
DCD. Consuegra
D. Consuegra
RDR. Dolenec
R. Dolenec
The detection of annihilation photons in positron emission tomography (PET) is based on scintillation light detection, but an interesting alternative is detection based on Cherenkov photons. Dense Cherenkov radiators provide an opportunity for high gamma detection efficiency—due to their high stopping power and photofraction—and excellent coincidence time resolution (CTR). However, because only a few tens of Cherenkov photons follow a gamma interaction in the radiator, the detection efficiency, and the energy resolution of a pure Cherenkov detector are an issue. This work explores gamma detection efficiency and CTR of PbF2-based detectors with different surface treatments and photodetectors covering one, two, or all crystal faces. Following the detector simulation analysis, we investigate the potential performance of a full-size Cherenkov PET scanner and quantitatively compare image quality with a commercial clinical PET scanner. We demonstrate that even though pure Cherenkov scanners have basically no energy resolution, the scatter fraction of around 50% is not prohibitively large, and images comparable to the state-of-the-art clinical PET scanner can be achieved due to improved efficiency and CTR attainable with PbF2.

26 November 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
RDRok Dolenec
Rok Dolenec
ELElmar Laistler
Elmar Laistler
Matija MilanicMatija Milanic
Matija Milanic
Rheumatoid arthritis causes changes in the optical properties of tissues in the joints, which could be detected using spectral imaging. This has the potential for development of low cost, non-contact method for early detection of the disease. In this work, hyperspectral imaging system was used to obtain 24 images of proximal interphalangeal joints of 12 healthy volunteers. A large inter-subject variability was observed, but still an increase in transmittance in the spectral range of 600 nm – 950 nm could be associated to the joint in all images. The results of experiments were compared to detailed simulations of light propagation trough tissue. For the simulations, voxelized 3D models of unaffected and inflamed human joints with realistic tissue distributions were constructed from an in-vivo MRI scan of a healthy human finger. The simulated model of healthy finger successfully reproduced the experimental data, while the affected models indicated that the inflammation introduces detectable differences in the spectral and spatial features. The results were used to guide the design of a dedicated imaging system for detection of rheumatoid arthritis, that will be used in an upcoming clinical study.