Eugenio Monticone

Dr. Eugenio Monticone


Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
MBM.G. Betti
M.G. Betti
MBM. Biasotti
M. Biasotti
ABAlberto Boscá
Alberto Boscá
FCF. Calle
F. Calle
NCN. Canci
N. Canci
KZK.M. Zurek
K.M. Zurek

1 May 2019 in Progress in Particle and Nuclear Physics
Verified
Journal Article
Closed access
MBM.G. Betti
M.G. Betti
MBM. Biasotti
M. Biasotti
ABAlberto Boscá
Alberto Boscá
FCF. Calle
F. Calle
JCJ. Carabe-Lopez
J. Carabe-Lopez
KZK.M. Zurek
K.M. Zurek

1 November 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
AAAlessio Avella
Alessio Avella
GBGiorgio Brida
Giorgio Brida
IDIvo Pietro Degiovanni
Ivo Pietro Degiovanni
Marco GenoveseMarco Genovese
Marco Genovese
Marco GramegnaMarco Gramegna
Marco Gramegna
MWM. White
M. White
Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.

22 July 2013 in Applied Physics Letters
Verified
Journal Article
Open access
LLLapo Lolli
Lapo Lolli
ETE. Taralli
E. Taralli
Chiara PortesiChiara Portesi
Chiara Portesi
EMEugenio Monticone
Eugenio Monticone
MRM. Rajteri
M. Rajteri
Transition Edge Sensors (TESs) are characterized by the intrinsic figures of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon detectors for quantum technology experiments. For a TES based on titanium and gold, has been reached, at telecommunication wavelength, an unprecedented intrinsic energy resolution (0.113 eV). The uncertainty analysis of both energy resolution and photon state assignment has been discussed. The thermal properties of the superconductive device have been studied by fitting the bias curves to evaluate the theoretical limit of the energy resolution.

1 December 2007 in Journal of Applied Physics
Verified
Journal Article
Closed access
GGGianluca Ghigo
Gianluca Ghigo
Francesco LavianoFrancesco Laviano
Francesco Laviano
LGL. Gozzelino
L. Gozzelino
RGR. Gerbaldo
R. Gerbaldo
EME. Mezzetti
E. Mezzetti
Chiara PortesiChiara Portesi
Chiara Portesi
The influence of dendritic magnetic-flux penetration on the microwave response of superconducting magnesium diboride (MgB2) films is investigated by a coplanar resonator technique. The characteristic feature consists of abrupt jumps in the resonance curves, which are shown to be induced by vortex avalanches freezing magnetic flux inside the resonator. Flux shaking provided by radio frequency currents is the origin of such avalanches, since a mechanism for magnetic instability of the dendrite type is local heating produced from flux motion. Once the external magnetic field has been changed, the interaction between microwave currents and flux lines influences the vortex-relaxation process. As a consequence, the vortex system is maintained close to a nonequilibrium state during the whole frequency sweep (few seconds), resulting in the observation of several events of dendrite nucleation and branching. From the analysis of a robust statistics, it results that avalanche-size distributions before and after flux-pinning tailoring by heavy-ion irradiation are fully consistent with a thermomagnetic model and with molecular dynamics simulations reported in literature.

29 June 2005 in Physical Review B
Verified
Journal Article
Closed access
PDF file
GGGianluca Ghigo
Gianluca Ghigo
DBD. Botta
D. Botta
Angelica ChiodoniAngelica Chiodoni
Angelica Chiodoni
LGLaura Gozzelino
Laura Gozzelino
RGR. Gerbaldo
R. Gerbaldo
Chiara PortesiChiara Portesi
Chiara Portesi
The microwave properties of polycrystalline MgB2 thin films prepared by the so-called in situ method are investigated. The characterization of the films at microwave frequencies was obtained by a coplanar resonator technique. The analysis of the experimental data results in the determination of penetration depth, surface impedance, and complex conductivity. The aim of this work is to set the experimental results in a consistent framework, involving the two-band model in the presence of impurity scattering. The energy gaps are calculated and the contribution of intra- and interband scattering is considered. From the comparison between the calculated gap values and the experimental data it turns out that the temperature dependence of the penetration depth can be accounted for by an effective mean energy gap, in agreement with the predictions of V. G. Kogan and N. V. Zhelezina [Phys. Rev. B 69, 132506 (2004)]. On the other hand, the temperature dependence of the real part of the microwave conductivity and of the surface resistance is accounted for by the single smaller gap, in agreement with the work of B. B. Jin, T. Dahm, A. I. Gubin, E.-M. Choi, H. J. Kim, S.-I. Lee, W. N. Kang, and N. Klein [Phys. Rev. Lett. 91, 127006 (2003)]. Since these findings rely on the same calculated gap structure, the required consistency is fulfilled.