Fabio Savoldi

Dr. Fabio Savoldi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Tissue Engineering
Verified
Journal Article
Open access
PDF file
Federica ReFederica Re
Federica Re
Luciana SartoreLuciana Sartore
Luciana Sartore
VMVladimira Moulisova
Vladimira Moulisova
MCMarco Cantini
Marco Cantini
CACamillo Almici
Camillo Almici
Domenico RussoDomenico Russo
Domenico Russo
Bone marrow and adipose tissue human mesenchymal stem cells were seeded in highly performing 3D gelatin–chitosan hybrid hydrogels of varying chitosan content in the presence of human platelet lysate and evaluated for their proliferation and osteogenic differentiation. Both bone marrow and adipose tissue human mesenchymal stem cells in gelatin–chitosan hybrid hydrogel 1 (chitosan content 8.1%) or gelatin–chitosan hybrid hydrogel 2 (chitosan 14.9%) showed high levels of viability (80%–90%), and their proliferation and osteogenic differentiation was significantly higher with human platelet lysate compared to fetal bovine serum, particularly in gelatin–chitosan hybrid hydrogel 1. Mineralization was detected early, after 21 days of culture, when human platelet lysate was used in the presence of osteogenic stimuli. Proteomic characterization of human platelet lysate highlighted 59 proteins mainly involved in functions related to cell adhesion, cellular repairing mechanisms, and regulation of cell differentiation. In conclusion, the combination of our gelatin–chitosan hybrid hydrogels with hPL represents a promising strategy for bone regenerative medicine using human mesenchymal stem cells.

7 September 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
LSLinda Sangalli
Linda Sangalli
FSFabio Savoldi
Fabio Savoldi
DOMENICO DALESSANDRIDOMENICO DALESSANDRI
DOMENICO DALESSANDRI
SBStefano Bonetti
Stefano Bonetti
MGMin Gu
Min Gu
Corrado PAGANELLICorrado PAGANELLI
Corrado PAGANELLI
Background: Remote digital monitoring during orthodontic treatment can help patients in improving their oral hygiene performance and reducing the number of appointments due to emergency reasons, especially in time of COVID-19 pandemic where non-urgent appointments might be discouraged. Methods: Thirty patients scheduled to start an orthodontic treatment were divided into two groups of fifteen. Compared to controls, study group patients were provided with scan box and cheek retractor (Dental Monitoring®) and were instructed to take monthly intra-oral scans. Plaque Index (PI), Gingival Index (GI), and White Spot Lesions (WSL) were recorded for both groups at baseline (t0), every month for the first 3 months (t1, t2, t3), and at 6 months (t4). Carious Lesions Onset (CLO) and Emergency Appointments (EA) were also recorded during the observation period. Inter-group differences were assessed with Student's t test and Chi-square test, intra-group differences were assessed with Cochran’s Q-test (significance α = 0.05). Results: Study group patients showed a significant improvement in plaque control at t3 (p = 0.010) and t4 (p = 0.039), compared to control group. No significant difference was observed in the number of WSL between the two groups. No cavities were detected in the study group, while five CLO were diagnosed in the control group (p = 0.049). A decreased number of EA was observed in the study group, but the difference was not significant. Conclusions: Integration of a remote monitoring system during orthodontic treatment was effective in improving plaque control and reducing carious lesions onset. The present findings encourage orthodontists to consider this technology to help maintaining optimal oral health of patients, especially in times of health emergency crisis.

14 January 2020 in The Angle Orthodontist
Verified
Journal Article
Closed access
FSFabio Savoldi
Fabio Savoldi
GXGou Xinyue
Gou Xinyue
CMColman P. McGrath
Colman P. McGrath
YYYanqi Yang
Yanqi Yang
SCShiu Cheuk Chow
Shiu Cheuk Chow
MGMin Gu
Min Gu
Objectives: To test the reliability of Lateral cephalometric radiographs (LCRs) for use in the assessment of the upper airway, hyoid bone, soft palate, and tongue. Materials and Methods: The records of 57 healthy Chinese children from a nonhospital population (mean age = 12.6 years, SD = 0.5, 28 males and 29 females) who received two consecutive LCRs in the natural head posture were retrospectively analyzed. Fifteen linear, angular, and area measurements were used to describe the airway, hyoid bone, soft palate, and tongue. The reliability between the two LCRs was assessed with the intraclass correlation coefficient (ICC) and F -test. Errors were estimated with the Dahlberg and Bland-Altman method, and intra- and inter-assessor agreements were determined. Results: Measurements of upper airway and hyoid bone had excellent method reliability, intra-assessor reliability, and inter-assessor reliability (ICC > 0.8). However, the method reliability and the inter-assessor reliability for soft palate and tongue was less favorable (ICC from 0.60 to 0.96). Soft palate area and thickness were the most critical parameters. Intra-assessor reliability was greater than both method reliability and inter-assessor reliability (which were similar). Conclusions: The measurement of upper airway morphology, defined as the intramural space, and of the hyoid bone position were highly reliable on LCRs of children. However, the limited reliability in the assessment of tongue and soft palate area may compromise the diagnostic application of LCRs to these structures.

25 March 2022 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
LSLinda Sangalli
Linda Sangalli
FSFabio Savoldi
Fabio Savoldi
DDDomenico Dalessandri
Domenico Dalessandri
LVLuca Visconti
Luca Visconti
FMFrancesca Massetti
Francesca Massetti
SBStefano Bonetti
Stefano Bonetti
Linda Sangalli, Fabio Savoldi, Domenico Dalessandri, Luca Visconti, Francesca Massetti, Stefano Bonetti. Korean J Orthod 2022;52:123-30. https://doi.org/10.4041/kjod.2022.52.2.123

1 February 2018 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Closed access
FSFabio Savoldi
Fabio Savoldi
James Kit Hon TsoiJames Kit Hon Tsoi
James Kit Hon Tsoi
Corrado PAGANELLICorrado PAGANELLI
Corrado PAGANELLI
JMJukka Matinlinna
Jukka Matinlinna
Sutures are synarthroses connecting the bones of the head each other through a fibrous sutural ligament. The knowledge of their biomechanical properties is relevant in the application of regenerative techniques for the treatment of craniofacial conditions, such as the sutural distraction osteogenesis (SDO). However, their mechanical characterisation has not received a systematic approach, and both clinical treatments and virtual simulations lack of clear mechanical parameters. Online databases (PubMed©, Cochrane Library©, Google Scholar©), references of full-text articles, and previous reviews of the literature were searched. Articles quantifying the biomechanical properties of human sutures were included without date, language, or publication restrictions. A qualitative analysis was carried based on source, sample, load, and measurements characteristics. Subsequently, mechanical parameters were discussed for each suture analysed. No previous review was found debating the topic. Seven studies were included, and only six sutures were analysed among the about forty existing ones, and important situations such as compressive and static loading were not considered. Only three studies analysing the coronal, sagittal, and metopic sutures provided a clear description of the methods and determined parameters of sutures of infants and children. Although a selective load application on sutures is capable to modify the craniofacial development, little is known about the optimal forces to be applied. The present findings may help to estimate the forces transferred to the sutural ligament during SDO when the strain is measured, and to advance the rationale of the application of certain parameters to optimise the clinical outcome.

23 January 2024 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
PDF file
FSFabio Savoldi
Fabio Savoldi
DDDorothea Dagassan-Berndt
Dorothea Dagassan-Berndt
RPRaphael Patcas
Raphael Patcas
WMWing-Sze Mak
Wing-Sze Mak
Georgios KanavakisGeorgios Kanavakis
Georgios Kanavakis
MBMichael M Bornstein
Michael M Bornstein
Applications of cone-beam CT (CBCT) in orthodontics have been increasingly discussed and evaluated in science and practice over the last two decades. The present work provides a comprehensive summary of current consolidated practice guidelines, cutting-edge innovative applications, and future outlooks about potential use of CBCT in orthodontics with a special focus on upper airway analysis in patients with sleep-disordered breathing. The present scoping review reveals that clinical applications of CBCT in orthodontics are broadly supported by evidence for the diagnosis of dental anomalies, temporomandibular joint disorders, and craniofacial malformations. On the other hand, CBCT imaging for upper airway analysis—including soft tissue diagnosis and airway morphology—needs further validation in order to provide better understanding regarding which diagnostic questions it can be expected to answer. Internationally recognized guidelines for CBCT use in orthodontics are existent, and similar ones should be developed to provide clear indications about the appropriate use of CBCT for upper airway assessment, including a list of specific clinical questions justifying its prescription.