Wencheng Shao

Dr. Wencheng Shao

Nanjing University of Aeronautics and Astronautics (NUAA)
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
WSWencheng Shao
Wencheng Shao
XLXin Lin
Xin Lin
YYYanling Yi
Yanling Yi
YHYing Huang
Ying Huang
LQLiangyong Qu
Liangyong Qu
HLHaikuan Liu
Haikuan Liu
Objectives . This study aims to develop a method for predicting patient-specific head organ doses by training a support vector regression (SVR) model based on radiomics features and graphics processing unit (GPU)-calculated reference doses. Methods . In this study, 237 patients who underwent brain CT scans were selected, and their CT data were transferred to an autosegmentation software to segment head regions of interest (ROIs). Subsequently, radiomics features were extracted from the CT data and ROIs, and the benchmark organ doses were computed using fast GPU-accelerated Monte Carlo (MC) simulations. The SVR organ dose prediction model was then trained using the radiomics features and benchmark doses. For the predicted organ doses, the relative root mean squared error (RRMSE), mean absolute percentage error (MAPE), and coefficient of determination ( R 2 ) were evaluated. The robustness of organ dose prediction was verified by changing the patient samples on the training and test sets randomly. Results . For all head organs, the maximal difference between the reference and predicted dose was less than 1 mGy. For the brain, the organ dose was predicted with an absolute error of 1.3%, and the R 2 reached up to 0.88. For the eyes and lens, the organ doses predicted by SVR achieved an RRMSE of less than 13%, the MAPE ranged from 4.5% to 5.5%, and the R 2 values were more than 0.7. Conclusions . Patient-specific head organ doses from CT examinations can be predicted within one second with high accuracy, speed, and robustness by training an SVR using radiomics features.

29 May 2025 in Precision Radiation Oncology
Verified
Journal Article
Open access
WSWencheng Shao
Wencheng Shao
LQLiangyong Qu
Liangyong Qu
XLXin Lin
Xin Lin
YHYing Huang
Ying Huang
WZWeihai Zhuo
Weihai Zhuo
HLHaikuan Liu
Haikuan Liu
Background: Computed Tomography (CT) imaging is essential for disease detection but carries a risk of cancer due to X‐ray exposure. Typically, assessing this risk requires segmentation of the internal organ contours to predict organ doses, which hinders its clinical application. This study introduces a method that uses support vector regression (SVR) models trained on skin outline radiomic features to predict organ doses without organ segmentation, thus streamlining the process for clinical use.Methods: CT scans of the head and abdomen were used to extract radiomic features of the skin outline. These features were used as inputs, with organ doses from Monte Carlo simulations as benchmarks to train the SVR models for predicting organ doses. The accuracy of the models was evaluated using the mean absolute percentage error (MAPE) and coefficient of determination (R2).Results: The results showed a high precision in dose prediction for various organs, including the brain (MAPE: 1.5%, R2: 0.9), eyes (MAPE: 5%, R2: 0.84), lens (MAPE: 5%, R2: 0.82), bowel (MAPE: 6%, R2: 0.84), kidneys (MAPE: 7.5%, R2: 0.7), and liver (MAPE: 8%, R2: 0.67). Internal organ disturbances had a minimal impact on accuracy.Conclusions: The SVR models efficiently predicted patient‐specific organ doses from CT scans, offering a user‐friendly tool for rapid segmentation‐free dose prediction. This innovation can significantly enhance clinical efficiency and accessibility in predicting patient‐specific organ doses using CT.

21 March 2025 in Radiation Science and Technology
Verified
Journal Article
Open access
PDF file
WSWencheng Shao
Wencheng Shao
XLXin Lin
Xin Lin
YHYing Hunag
Ying Hunag
LQLiangyong Qu
Liangyong Qu
WZWeihai Zhuo
Weihai Zhuo
HLHaikuan Liu
Haikuan Liu
Background: CT examinations are commonly utilized for the diagnosis of internal diseases. The X-rays emitted during CT scans can elevate the risks of developing solid cancers by causing DNA damage. The risk of CT scan-induced solid cancers is intricately linked to the organ doses specific to each patient. The Support Vector Regression (SVR) algorithm exhibits the capability to swiftly and accurately predict organ doses. Kernel functions, including linear, polynomial, and radial basis (RBF) functions, play a crucial role in the overall performance of SVR when predicting patient-specific organ doses from CT scans. Therefore, it is imperative to investigate the influence of kernel selection on the comprehensive predictive effectiveness of SVR. Purpose: This study investigates the impact of kernel functions on the predictive performance of SVR models trained by radiomics features, and to pinpoint the optimal kernel function for predicting patient-specific organ doses from CT scans. Methods: CT images from head and abdominal CT scans were processed using DeepViewer, an auto-segmentation tool for defining regions of interest (ROIs) within their organs. Radiomics features were extracted from the CT data and ROIs. Benchmark organ doses were calculated through Monte Carlo simulations. SVR models, utilizing the radiomics features, were trained with linear-, polynomial-, and RBF kernels to predict patient-specific organ doses from CT scans. The robustness of the SVR prediction was examined by applying 25 random sample splits with each kernel. The mean absolute percentage error (MAPE) and coefficient of determination (R2) were compared among the kernels to identify the optimal kernel. Results: The linear kernel obtains better overall predictive performance than the polynomial and RBF kernels. The SVR trained with the linear kernel function achieves lower MAPE values, below 5% for head organs and under 6.8% for abdominal organs. Furthermore, it shows higher R2 values exceeding 0.85 for head organs and going beyond 0.8 for abdominal organs. Conclusions: Kernel selection severely impact the overall performance of SVR models. The optimal kernel varies with CT scanned parts and organ types indicating the necessity to conduct organ-specific kernel selection.

29 April 2021 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
WSWencheng Shao
Wencheng Shao
ZCZiyin Chen
Ziyin Chen
YBYanchun Bai
Yanchun Bai
BXBingchen Xu
Bingchen Xu
LXLili Xu
Lili Xu
XTXiaobin Tang
Xiaobin Tang
PURPOSE: This study aims to evaluate the planned dose of stereotactic body radiation therapy (SBRT) for treating early peripheral non-small cell lung cancer (NSCLC) using the non-coplanar radiation from Cyberknife and Varian linac. Moreover, this study investigates whether Cyberknife and Varian linac are qualified for non-coplanar radiation SBRT for treating early peripheral NSCLC, and which one is better for protecting organs at risk (OARs). METHODS: Retrospective analysis was performed based on the Cyberknife radiation treatment plans (RTPs) and Varian Eclipse RTPs of 10 patients diagnosed with early peripheral NSCLC. The dose distributions in the target and OARs were compared between the RTPs of Cyberknife and Varian Eclipse using Mim medical imaging software. RESULTS: For PTV, no significant difference in D98 and D95 between the Cyberknife and Eclipse was observed ( t = –0.35, –1.67, P > 0.05). The homogeneity indexes (HIs) of Cyberknife plans are higher ( t = 71.86, P < 0.05) than those of Eclipse plans. The V10, V15, V20, V25, V30 and Dmean of the lung with NSCLC and the V20 of the whole lung for Cyberknife were less than those for Eclipse ( t = –4.73, –5.62, –7.75, –6.38, –6.89, –3.14, –7.09, respectively, P < 0.05). Cyberknife plans have smaller spinal cord Dmax, trachea Dmax, heart Dmax, chest wall Dmax ( t = –2.49, –2.57, –3.71, –3.56, respectively, P < 0.05) and esophagus Dmax ( t = –1.95, P > 0.05) than Varian Eclipse plans. CONCLUSION: To fulfill SBRT by non-coplanar radiation, Cyberknife is recommended for the institutions equipped with Cyberknife, while Varian linac can be applied for the institutions that have not adopted Cyberknife in clinical radiotherapy yet.

9 September 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
WSWencheng Shao
Wencheng Shao
YXYunhe Xie
Yunhe Xie
JWJianan Wu
Jianan Wu
LZLiyan Zhang
Liyan Zhang
Jan SchuemannJan Schuemann
Jan Schuemann
HLHsiao-Ming Lu
Hsiao-Ming Lu
This study aims to develop a method for verifying site-specific and/or beam path specific proton beam range, which could reduce range uncertainty margins and the associated treatment complications. It investigates the range uncertainties from both CT HU to relative stopping power conversion and patient positioning errors for prostate treatment using pelvic-like biological phantoms. Three 25 × 14 × 12 cm 3 phantoms, made of fresh animal tissues mimicking the pelvic anatomies of prostate patients, were scanned with a general electric CT simulator. A 22 cm circular passive scattering beam with 29 cm range and 8 cm modulation width was used to measure the water equivalent path lengths (WEPL) through the phantoms at multiple points using the dose extinction method with a MatriXXPT detector. The measured WEPLs were compared to those predicted by TOPAS simulations and ray-tracing WEPL calculations. For the three phantoms, the WEPL differences between measured and theoretical prediction (WDMT) are below 1.8% for TOPAS, and 2.5% for ray-tracing. WDMT varies with phantom anatomies by about 0.5% for both TOPAS and ray-tracing. WDMT also correlates with the tissue types of a specific treated region. For the regions where the proton beam path is parallel to sharp bone edges, the WDMTs of TOPAS and ray-tracing respectively reach up to 1.8% and 2.5%. For the region where proton beams pass through just soft tissues, the WDMT is mostly less than 1% for both TOPAS and ray-tracing. For prostate treatments, range uncertainty depends on the tissue types within a specific treated region, patient anatomies and the range calculation methods in the planning algorithms. Our study indicates range uncertainty is less than 2.5% for the whole treated region with both ray-tracing and TOPAS, which suggests the potential to reduce the current 3.5% range uncertainty margin used in the clinics by at least 1% even for single-energy CT data.

23 September 2024 in Advanced Intelligent Systems
Verified
Journal Article
Open access
WSWencheng Shao
Wencheng Shao
ZWZhenfa Wan
Zhenfa Wan
KYKe Yang
Ke Yang
XLXin Lin
Xin Lin
LQLiangyong Qu
Liangyong Qu
HLHaikuan Liu
Haikuan Liu
This study aims to establish and validate a cross‐institutional prediction system for estimating patient‐specific organ doses from chest CT scans. By collaborating across multiple institutions, the study seeks to develop models that allow rapid online estimation of organ doses, eliminating the need for complex organ segmentation. Researchers delineate skin outlines from chest CT images obtained from two different institutions. Radiomics features are extracted from the chest CT data and skin contours. Organ doses are computed using Monte Carlo simulations as reference organ doses. Single‐ and cross‐institutional support vector regression (SVR) models are trained with radiomics features to predict organ doses from chest CT scans. Model performance is assessed using metrics like maean absolute percentage error (MAPE) and R‐squared (R2). For chest organs (lungs, heart, spinal cord, trachea, and esophagus), single‐institutional SVR models achieve MAPE values ranging from 4.72% to 15.31% and R2 values from 0.73 to 0.93. Cross‐institutional models have MAPE values in the range of 2.16–7.49% and R2 values from 0.84 to 0.99. SVR models trained with radiomics features from skin outlines can reliably estimate organ doses from chest CT scans. The proposed method is applicable across different institutions, and cross‐institutional models enhance predictive accuracy, generality, and robustness.