Tatsuyuki Nakatani

Prof. Tatsuyuki Nakatani

Okayama University of Science
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2019 in Journal of Photopolymer Science and Technology
Verified
Journal Article
Open access
PDF file
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
HTHarumichi Takeuchi
Harumichi Takeuchi
AWAkira Wada
Akira Wada
SYShuzo Yamashita
Shuzo Yamashita
The bioabsorbable magnesium alloy stent exhibits a high dissolution rate; therefore, it faces difficulty in achieving long-term vascular support rigidity. Thus, the control of dissolution rate using a diamond-like carbon (DLC) coating exhibiting excellent biocompatibility is studied. A conventional DLC is usually peeled off from the substrate when the stent expands. The Si-doped DLC (Si–DLC) is considered to be an elastic film candidate for solving this problem. However, the effectiveness of dissolution rate control has not yet been clarified. In this research, we intend to verify the corrosion behavior to confirm the possibility of controlling the dissolution rate of a bioabsorbable magnesium alloy coated with a Si–DLC film using a 13.56 MHz radio-frequency (RF) plasma chemical vapor deposition (CVD) apparatus. Further, the corrosion behavior was examined using electrochemical measurement by cyclic voltammetry. It was observed after repeated oxidation–reduction reaction that Si–DLC can not only drastically diminish the corrosion current value and the pH in the physiological saline solution but also suppress the local corrosion unlike the untreated magnesium alloy and DLC. Thus, the possibility of dissolution velocity control was confirmed.

Verified
Journal Article
Open access
PDF file
YFYasuhiro Fujii
Yasuhiro Fujii
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
Daiki OusakaDaiki Ousaka
Daiki Ousaka
SOSusumu Oozawa
Susumu Oozawa
YSYasushi Sasai
Yasushi Sasai
SKShingo Kasahara
Shingo Kasahara
The medical device market is a high-growth sector expected to sustain an annual growth rate of over 5%, even in developed countries. Daily, numerous patients have medical devices implanted or inserted within their bodies. While medical devices have significantly improved patient outcomes, as foreign objects, their wider use can lead to an increase in device-related infections, thereby imposing a burden on healthcare systems. Multiple materials with significant societal impact have evolved over time: the 19th century was the age of iron, the 20th century was dominated by silicon, and the 21st century is often referred to as the era of carbon. In particular, the development of nanocarbon materials and their potential applications in medicine are being explored, although the scope of these applications remains limited. Technological innovations in carbon materials are remarkable, and their application in medicine is expected to advance greatly. For example, diamond-like carbon (DLC) has garnered considerable attention for the development of antimicrobial surfaces. Both DLC itself and its derivatives have been reported to exhibit anti-microbial properties. This review discusses the current state of DLC-based antimicrobial surface development.

1 January 2014 in Journal of Photopolymer Science and Technology
Verified
Journal Article
Closed access
YMYuichi Mine
Yuichi Mine
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
KOKeishi Okamoto
Keishi Okamoto
SHShintarou Hara
Shintarou Hara
KTKentaro Takagi
Kentaro Takagi
HNHiroki Nikawa
Hiroki Nikawa

20 March 2023 in Diamond and Related Materials
Verified
Journal Article
Closed access
HFHiroyuki Fukue
Hiroyuki Fukue
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
TOTadayuki Okano
Tadayuki Okano
MKMasahide Kuroiwa
Masahide Kuroiwa
SKShinsuke Kunitsugu
Shinsuke Kunitsugu
KYKen Yonezawa
Ken Yonezawa

22 December 2020 in Processes
Verified
Journal Article
Open access
PDF file
SHSUNGHWA HWANG
SUNGHWA HWANG
KKKazunori Koga
Kazunori Koga
YHYuan Hao
Yuan Hao
Pankaj AttriPankaj Attri
Pankaj Attri
TOTakamasa Okumura
Takamasa Okumura
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
As the application of nanotechnology increases continuously, the need for controlled size nanoparticles also increases. Therefore, in this work, we discussed the growth mechanism of carbon nanoparticles generated in Ar+CH4 multi-hollow discharge plasmas. Using the plasmas, we succeeded in continuous generation of hydrogenated amorphous carbon nanoparticles with controlled size (25–220 nm) by the gas flow. Among the nanoparticle growth processes in plasmas, we confirmed the deposition of carbon-related radicals was the dominant process for the method. The size of nanoparticles was proportional to the gas residence time in holes of the discharge electrode. The radical deposition developed the nucleated nanoparticles during their transport in discharges, and the time of flight in discharges controlled the size of nanoparticles.

16 December 2022 in Journal of Photopolymer Science and Technology
Verified
Journal Article
Open access
PDF file
YIYuichi Imai
Yuichi Imai
HFHiroyuki Fukue
Hiroyuki Fukue
Tatsuyuki NakataniTatsuyuki Nakatani
Tatsuyuki Nakatani
SKShinsuke Kunitsugu
Shinsuke Kunitsugu
KKKazuhiro Kanda
Kazuhiro Kanda
TUTomio Uchi
Tomio Uchi
Silicone tubing is used in small-diameter long-sized tubes for medical applications, such as urinary catheters. However, bacteria in urine adhere to the catheters, forming colonies and biofilms and resulting in blockages and urinary tract infections. Therefore, we have reported a method of AC high-voltage plasma chemical vapor deposition to prevent bacterial adhesion by depositing diamond-like carbon (DLC) on a lumen of a silicone catheter and smoothing the surface. However, the sp3/sp2 structure of DLC on the lumen surface is unresolved, and biomimetic DLC with a functionalized surface has not been investigated. Therefore, we analyzed a flexible membrane structure that can deform as the resin tube deforms. In addition, we developed a lumen surface-modification method using an AC high-voltage burst oxygen plasma processing to bring the DLC surface closer to the in vivo environment. We succeeded in creating biomimetic DLC and introducing carboxyl groups. Using this technology, the surface functionalization of medical tube materials is biocompatible with various protein-adsorption properties.