Kanae Taruno

Dr. Kanae Taruno

Division of breast surgical oncology, Department of Surgery, Showa University, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2019 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
KTKanae Taruno
Kanae Taruno
TKTomoko Kurita
Tomoko Kurita
AKAkihiko Kuwahata
Akihiko Kuwahata
KYKeiko Yanagihara
Keiko Yanagihara
KEKatsutoshi Enokido
Katsutoshi Enokido
MKMoriaki Kusakabe
Moriaki Kusakabe

11 June 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Tomoko KuritaTomoko Kurita
Tomoko Kurita
KTKanae Taruno
Kanae Taruno
Seigo NakamuraSeigo Nakamura
Seigo Nakamura
Hiroyuki TakeiHiroyuki Takei
Hiroyuki Takei
KEKatsutoshi Enokido
Katsutoshi Enokido
MKMoriaki Kusakabe
Moriaki Kusakabe
Accurate pre-operative localization of nonpalpable lesions plays a pivotal role in guiding breast-conserving surgery (BCS). In this multicenter feasibility study, nonpalpable breast lesions were localized using a handheld magnetic probe (TAKUMI) and a magnetic marker (Guiding-Marker System®). The magnetic marker was preoperatively placed within the target lesion under ultrasound or stereo-guidance. Additionally, a dye was injected subcutaneously to indicate the extent of the tumor excision. Surgeons checked for the marker within the lesion using a magnetic probe. The magnetic probe could detect the guiding marker and accurately localize the target lesion intraoperatively. All patients with breast cancer underwent wide excision with a safety margin of ≥5 mm. The presence of the guiding-marker within the resected specimen was the primary outcome and the pathological margin status and re-excision rate were the secondary outcomes. Eighty-seven patients with nonpalpable lesions who underwent BCS, from January to March of 2019 and from January to July of 2020, were recruited. The magnetic marker was detected in all resected specimens. The surgical margin was positive only in 5/82 (6.1%) patients; these patients underwent re-excision. This feasibility study demonstrated that the magnetic guiding localization system is useful for the detection and excision of nonpalpable breast lesions.

29 June 2022 in Breast Cancer
Verified
Journal Article
Open access
PDF file
RHRikako Hashimoto
Rikako Hashimoto
SASadako Akashi-Tanaka
Sadako Akashi-Tanaka
CWChie Watanabe
Chie Watanabe
HMHiroko Masuda
Hiroko Masuda
KTKanae Taruno
Kanae Taruno
Seigo NakamuraSeigo Nakamura
Seigo Nakamura
Background: Dedicated breast positron emission tomography (dbPET) has been developed for detecting smaller breast cancer. We investigated the diagnostic performance of dbPET in patients with known breast cancer. Methods: Eighty-two preoperative patients with breast cancer were included in the study (84 tumours: 11 ductal carcinomas in situ [DCIS], 73 invasive cancers). They underwent mammography (MMG), ultrasonography (US), and contrast-enhanced breast magnetic resonance imaging (MRI) before whole-body PET/MRI (WBPET/MRI) and dbPET. We evaluated the sensitivity of all modalities, and the association between the maximum standard uptake value (SUVmax) level and histopathological features. Results: The sensitivities of MMG, US, MRI, WBPET/MRI and dbPET for all tumours were 81.2% (65/80), 98.8% (83/84), 98.6% (73/74), 86.9% (73/84), and 89.2% (75/84), respectively. For 11 DCIS and 22 small invasive cancers (≤ 2 cm), the sensitivity of dbPET (84.9%) tended to be higher than that of WBPET/MRI (69.7%) (p = 0.095). Seven tumours were detected by dbPET only, but not by WBPET/MRI. Five tumours were detected by only WBPET/MRI because of the blind area of dbPET detector, requiring a wider field of view. After making the mat of dbPET detector thinner, all 22 scanned tumours were depicted. The higher SUVmax of dbPET was significantly related to the negative oestrogen receptor status, higher nuclear grade, and higher Ki67 (p < 0.001). Conclusions: The sensitivity of dbPET for early breast cancer was higher than that of WBPET/MRI. High SUVmax was related to aggressive features of tumours. Moreover, dbPET can be used for the diagnosis and oncological evaluation of breast cancer.

10 March 2022 in Cancers
Verified
Journal Article
Open access
PDF file
KTKanae Taruno
Kanae Taruno
AKAkihiro Kuwahata
Akihiro Kuwahata
MSMasaki Sekino
Masaki Sekino
TNTakayuki Nakagawa
Takayuki Nakagawa
Tomoko KuritaTomoko Kurita
Tomoko Kurita
MKMoriaki Kusakabe
Moriaki Kusakabe
This exploratory study compared doses of ferucarbotran, a superparamagnetic iron oxide nanoparticle, in sentinel lymph nodes (SLNs) and quantified the SLN iron load by dose and localization. Eighteen females aged ≥20 years scheduled for an SLN biopsy with node-negative breast cancer were divided into two equal groups and administered either 1 mL or 0.5 mL ferucarbotran. Iron content was evaluated with a handheld magnetometer and quantification device. The average iron content was 42.8 µg (range, 1.3–95.0; 0.15% of the injected dose) and 21.9 µg (1.1–71.0; 0.16%) in the 1-mL and 0.5-mL groups, respectively (p = 0.131). The iron content of the closest SLN compared to the second SLN was 53.0 vs. 10.0 µg (19% of the injected dose) and 34.8 vs. 4.1 µg (11.1%) for the 1-mL and 0.5-mL groups, respectively (p = 0.001 for both). The magnetic field was high in both groups (average 7.30 µT and 6.00 µT in the 1-mL and 0.5-mL groups, respectively) but was not statistically significant (p = 0.918). The magnetic field and iron content were correlated (overall SLNs, p = 0.02; 1-mL, p = 0.014; 0.5-mL, p = 0.010). A 0.5-mL dose was sufficient for SLN identification. Primary and secondary SLNs could be differentiated based on iron content. Handheld magnetometers could be used to assess the SLN iron content.

21 July 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
AKAkihiro Kuwahata
Akihiro Kuwahata
KTKanae Taruno
Kanae Taruno
Tomoko KuritaTomoko Kurita
Tomoko Kurita
MMMasujiro Makita
Masujiro Makita
SCShinichi Chikaki
Shinichi Chikaki
MSMasaki Sekino
Masaki Sekino
To minimize invasiveness and improve patient’s quality of life, sentinel lymph node biopsy with magnetic nanoparticles containing superparamagnetic iron oxide is performed on breast cancer patients. Identifying the first sentinel lymph node by quantification of the amount of magnetic nanoparticles can help to investigate cancer metastasis. We developed the device for performing iron quantification during surgery. The compact desktop-size device can be easily introduced into operation rooms, and simple system enables identification of the first sentinel lymph node. We investigated the optimum nonlinear magnetic responses that are attributed to magnetic relaxations under moderate small AC and DC magnetic fields (∼1 mT), and found AC magnetic fields with <5 kHz to be effective in the detection of magnetic nanoparticles. In addition, our clinical trials revealed more iron (40 μg) in the first lymph node than in the second lymph node (10 μg), clearly indicating intraoperative quantification in the first node.

14 December 2021 in Current Oncology
Verified
Journal Article
Open access
PDF file
RYReika Yoshida
Reika Yoshida
TYTakenori Yamauchi
Takenori Yamauchi
SASadako Akashi-Tanaka
Sadako Akashi-Tanaka
MMMisaki Matsuyanagi
Misaki Matsuyanagi
KTKanae Taruno
Kanae Taruno
Seigo NakamuraSeigo Nakamura
Seigo Nakamura
Dense breasts are a risk factor for breast cancer. Assessment of breast density is important and radiologist-dependent. We objectively measured mammographic density using the three-dimensional automatic mammographic density measurement device Volpara™ and examined the criteria for combined use of ultrasonography (US). Of 1227 patients who underwent primary breast cancer surgery between January 2019 and April 2021 at our hospital, 441 were included. A case series study was conducted based on patient age, diagnostic accuracy, effects of mammography (MMG) combined with US, size of invasion, and calcifications. The mean density of both breasts according to the Volpara Density Grade (VDG) was 0–3.4% in 2 patients, 3.5–7.4% in 55 patients, 7.5–15.4% in 173 patients, and ≥15.5% in 211 patients. Breast density tended to be higher in younger patients. Diagnostic accuracy of MMG tended to decrease with increasing breast density. US detection rates were not associated with VDG on MMG and were favorable at all densities. The risk of a non-detected result was high in patients without malignant suspicious calcifications. Supplementary use of US for patients without suspicious calcifications on MMG and high breast density, particularly ≥25.5%, could improve the breast cancer detection rate.