Karin Markenroth Bloch

Dr. Karin Markenroth Bloch

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 1999 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MFM. Freer
M. Freer
JAJ. C. Angélique
J. C. Angélique
LAL. Axelsson
L. Axelsson
BBB. Benoit
B. Benoit
UBU. Bergmann
U. Bergmann
DWD. L. Watson
D. L. Watson
The breakup of 12Be into 6He+6He and 4He+8He has been studied using a 378 MeV 12Be beam inelastically excited by 12C and (CH2)n targets. The measurements indicate that breakup occurs from rotational states in the 10 to 25 MeV excitation energy interval, with spins in the range of 4ħ to 8ħ. The inferred moment of inertia is consistent with the cluster decay of an exotic molecular structure in 12Be, which may be associated with an α−4n−α cluster configuration.

1 July 2007 in Nuclear Physics A
Verified
Journal Article
Closed access
HSH. Simon
H. Simon
MMM. Meister
M. Meister
TAT. Aumann
T. Aumann
MBM.J.G. Borge
M.J.G. Borge
LCL.V. Chulkov
L.V. Chulkov
MZM.V. Zhukov
M.V. Zhukov

22 December 2020 in Neurology
Verified
Journal Article
Closed access
PDF file
GOGiske Opheim
Giske Opheim
AKAnja van der Kolk
Anja van der Kolk
KBKarin Markenroth Bloch
Karin Markenroth Bloch
ACAlbert J. Colon
Albert J. Colon
KDKathryn A. Davis
Kathryn A. Davis
MGMaxime Guye
Maxime Guye
Identifying a structural brain lesion on MRI has important implications in epilepsy and is the most important factor that correlates with seizure freedom after surgery in patients with drug-resistant focal onset epilepsy. However, at conventional magnetic field strengths (1.5 and 3T), only approximately 60%–85% of MRI examinations reveal such lesions. Over the last decade, studies have demonstrated the added value of 7T MRI in patients with and without known epileptogenic lesions from 1.5 and/or 3T. However, translation of 7T MRI to clinical practice is still challenging, particularly in centers new to 7T, and there is a need for practical recommendations on targeted use of 7T MRI in the clinical management of patients with epilepsy. The 7T Epilepsy Task Force—an international group representing 21 7T MRI centers with experience from scanning over 2,000 patients with epilepsy—would hereby like to share its experience with the neurology community regarding the appropriate clinical indications, patient selection and preparation, acquisition protocols and setup, technical challenges, and radiologic guidelines for 7T MRI in patients with epilepsy. This article mainly addresses structural imaging; in addition, it presents multiple nonstructural MRI techniques that benefit from 7T and hold promise as future directions in epilepsy. Answering to the increased availability of 7T MRI as an approved tool for diagnostic purposes, this article aims to provide guidance on clinical 7T MRI epilepsy management by giving recommendations on referral, suitable 7T MRI protocols, and image interpretation.

1 January 2011 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MCMarcus Carlsson
Marcus Carlsson
JTJohannes Töger
Johannes Töger
MKMikael Kanski
Mikael Kanski
KBKarin Markenroth Bloch
Karin Markenroth Bloch
FSFreddy Ståhlberg
Freddy Ståhlberg
HAHåkan Arheden
Håkan Arheden
Three-dimensional time-resolved (4D) phase-contrast (PC) CMR can visualize and quantify cardiovascular flow but is hampered by long acquisition times. Acceleration with SENSE or k-t BLAST are two possibilities but results on validation are lacking, especially at 3 T. The aim of this study was therefore to validate quantitative in vivo cardiac 4D-acquisitions accelerated with parallel imaging and k-t BLAST at 1.5 T and 3 T with 2D-flow as the reference and to investigate if field strengths and type of acceleration have major effects on intracardiac flow visualization.

1 March 2000 in Physics Letters B
Verified
Journal Article
Closed access
FMF.M. Marqués
F.M. Marqués
MLM. Labiche
M. Labiche
NON.A. Orr
N.A. Orr
JAJ.C. Angélique
J.C. Angélique
LAL. Axelsson
L. Axelsson
LSL. Stuttgé
L. Stuttgé

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MCMarcus Carlsson
Marcus Carlsson
RARuslana Andersson
Ruslana Andersson
KBKarin Markenroth Bloch
Karin Markenroth Bloch
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
HMHenrik Mosén
Henrik Mosén
HAHakan Arheden
Hakan Arheden
Cardiovascular Magnetic Resonance (CMR) enables non-invasive quantification of cardiac output (CO) and thereby cardiac index (CI, CO indexed to body surface area). The aim of this study was to establish if CI decreases with age and compare the values to CI for athletes and for patients with congestive heart failure (CHF).