Katarina Steding-Ehrenborg

Dr. Katarina Steding-Ehrenborg


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MCMarcus Carlsson
Marcus Carlsson
RARuslana Andersson
Ruslana Andersson
KBKarin Markenroth Bloch
Karin Markenroth Bloch
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
HMHenrik Mosén
Henrik Mosén
HAHakan Arheden
Hakan Arheden
Cardiovascular Magnetic Resonance (CMR) enables non-invasive quantification of cardiac output (CO) and thereby cardiac index (CI, CO indexed to body surface area). The aim of this study was to establish if CI decreases with age and compare the values to CI for athletes and for patients with congestive heart failure (CHF).

1 February 2017 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
PAPer M. Arvidsson
Per M. Arvidsson
JTJohannes Töger
Johannes Töger
MCMarcus Carlsson
Marcus Carlsson
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
GPGianni Pedrizzetti
Gianni Pedrizzetti
HAHåkan Arheden
Håkan Arheden
Intracardiac blood flow is driven by hemodynamic forces that are exchanged between the blood and myocardium. Previous studies have been limited to 2D measurements or investigated only left ventricular (LV) forces. Right ventricular (RV) forces and their mechanistic contribution to asymmetric redirection of flow in the RV have not been measured. We therefore aimed to quantify 3D hemodynamic forces in both ventricles in a cohort of healthy subjects, using magnetic resonance imaging 4D flow measurements. Twenty five controls, 14 elite endurance athletes, and 2 patients with LV dyssynchrony were included. 4D flow data were used as input for the Navier-Stokes equations to compute hemodynamic forces over the entire cardiac cycle. Hemodynamic forces were found in a qualitatively consistent pattern in all healthy subjects, with variations in amplitude. LV forces were mainly aligned along the apical-basal longitudinal axis, with an additional component aimed toward the aortic valve during systole. Conversely, RV forces were found in both longitudinal and short-axis planes, with a systolic force component driving a slingshot-like acceleration that explains the mechanism behind the redirection of blood flow toward the pulmonary valve. No differences were found between controls and athletes when indexing forces to ventricular volumes, indicating that cardiac force expenditures are tuned to accelerate blood similarly in small and large hearts. Patients’ forces differed from controls in both timing and amplitude. Normal cardiac pumping is associated with specific force patterns for both ventricles, and deviation from these forces may be a sensitive marker of ventricular dysfunction. Reference values are provided for future studies.NEW & NOTEWORTHY Biventricular hemodynamic forces were quantified for the first time in healthy controls and elite athletes (n = 39). Hemodynamic forces constitute a slingshot-like mechanism in the right ventricle, redirecting blood flow toward the pulmonary circulation. Force patterns were similar between healthy subjects and athletes, indicating potential utility as a cardiac function biomarker.

1 January 2016 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
PAP. M. Arvidsson
P. M. Arvidsson
JTJ. Töger
J. Töger
MRM. Rydberg
M. Rydberg
EHE. Heiberg
E. Heiberg
HAH. Arheden
H. Arheden
The kinetic energy (KE) of intracardiac blood may play an important role in cardiac function. The aims of the present study were to 1) quantify and investigate the determinants of KE, 2) compare the KE expenditure of intracardiac blood between athletes and control subjects, and 3) quantify the amount of KE inside and outside the diastolic vortex. Fourteen athletes and fourteen volunteers underwent cardiac MRI, including four-dimensional phase-contrast sequences. KE was quantified in four chambers, and energy expenditure was calculated by determining the mean KE/cardiac index. Left ventricular (LV) mass was an independent predictor of diastolic LVKE ( R2= 0.66, P < 0.001), whereas right ventricular (RV) end-diastolic volume was important for diastolic RVKE ( R2= 0.76, P < 0.001). The mean KE/cardiac index did not differ between groups (control subjects: 0.53 ± 0.14 mJ·l−1·min·m2and athletes: 0.56 ± 0.21 mJ·l−1·min·m2, P = 0.98). Mean LV diastolic vortex KE made up 70 ± 1% and 73 ± 2% of total LV diastolic KE in athletes and control subjects ( P = 0.18). In conclusion, the characteristics of the LV as a pressure pump and the RV as a volume pump are demonstrated as an association between LVKE and LV mass and between RVKE and end-diastolic volume. This also suggests different filling mechanisms where the LV is dependent on diastolic suction, whereas the RV fills with a basal movement of the atrioventricular plane over “stationary” blood. Both groups had similar energy expenditure for intracardiac blood flow, indicating similar pumping efficiency, likely explained by the lower heart rate that cancels the higher KE per heart beat in athletes. The majority of LVKE is found within the LV diastolic vortex, in contrast to earlier findings.

18 June 2015 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
MKMikael Kanski
Mikael Kanski
JTJohannes Töger
Johannes Töger
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
CXChristos Xanthis
Christos Xanthis
KBKarin Markenroth Bloch
Karin Markenroth Bloch
HAHåkan Arheden
Håkan Arheden
Respiratory gating is often used in 4D-flow acquisition to reduce motion artifacts. However, gating increases scan time. The aim of this study was to investigate if respiratory gating can be excluded from 4D flow acquisitions without affecting quantitative intracardiac parameters. Eight volunteers underwent CMR at 1.5 T with a 5-channel coil (5ch). Imaging included 2D flow measurements and whole-heart 4D flow with and without respiratory gating (Resp(+), Resp(−)). Stroke volume (SV), particle-trace volumes, kinetic energy, and vortex-ring volume were obtained from 4D flow-data. These parameters were compared between 5ch Resp(+) and 5ch Resp(−). In addition, 20 patients with heart failure were scanned using a 32-channel coil (32ch), and particle-trace volumes were compared to planimetric SV. Paired comparisons were performed using Wilcoxon’s test and correlation analysis using Pearson r. Agreement was assessed as bias ± SD. Stroke volume from 4D flow was lower compared to 2D flow both with and without respiratory gating (5ch Resp(+) 88 ± 18 vs 97 ± 24.0, p = 0.001; 5ch Resp(−) 86 ± 16 vs 97.1 ± 22.7, p < 0.01). There was a good correlation between Resp(+) and Resp(−) for particle-trace derived volumes (R2 = 0.82, 0.2 ± 9.4 ml), mean kinetic energy (R2 = 0.86, 0.07 ± 0.21 mJ), peak kinetic energy (R2 = 0.88, 0.14 ± 0.77 mJ), and vortex-ring volume (R2 = 0.70, −2.5 ± 9.4 ml). Furthermore, good correlation was found between particle-trace volume and planimetric SV in patients for 32ch Resp(−) (R2 = 0.62, −4.2 ± 17.6 ml) and in healthy volunteers for 5ch Resp(+) (R2 = 0.89, −11 ± 7 ml), and 5ch Resp(−) (R2 = 0.93, −7.5 ± 5.4 ml), Average scan duration for Resp(−) was shorter compared to Resp(+) (27 ± 9 min vs 61 ± 19 min, p < 0.05). Whole-heart 4D flow can be acquired with preserved quantitative results without respiratory gating, facilitating clinical use.

28 February 2017 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
FSFelicia Seemann
Felicia Seemann
UPUlrika Pahlm
Ulrika Pahlm
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
EOEllen Ostenfeld
Ellen Ostenfeld
DEDavid Erlinge
David Erlinge
EHEinar Heiberg
Einar Heiberg
Atrioventricular plane displacement (AVPD) is an indicator for systolic and diastolic function and accounts for 60% of the left ventricular, and 80% of the right ventricular stroke volume. AVPD is commonly measured clinically in echocardiography as mitral and tricuspid annular plane systolic excursion (MAPSE and TAPSE), but has not been applied widely in cardiovascular magnetic resonance (CMR). To date, there is no robust automatic algorithm available that allows the AVPD to be measured clinically in CMR with input in a single timeframe. This study aimed to develop, validate and provide a method that automatically tracks the left and right ventricular AVPD in CMR images, which can be used in the clinical setting or in applied cardiovascular research in multi-center studies. The proposed algorithm is based on template tracking by normalized cross-correlation combined with a priori information by principal component analysis. The AVPD in each timeframe is calculated for the left and right ventricle separately using CMR long-axis cine images of the 2, 3, and 4-chamber views. The algorithm was developed using a training set (n = 40), and validated in a test set (n = 113) of healthy subjects, athletes, and patients after ST-elevation myocardial infarction from 10 centers. Validation was done using manual measurements in end diastole and end systole as reference standard. Additionally, AVPD, peak emptying velocity, peak filling velocity, and atrial contraction was validated in 20 subjects, where time-resolved manual measurements were used as reference standard. Inter-observer variability was analyzed in 20 subjects. In end systole, the difference between the algorithm and the reference standard in the left ventricle was (mean ± SD) -0.6 ± 1.9 mm (R = 0.79), and −0.8 ± 2.1 mm (R = 0.88) in the right ventricle. Inter-observer variability in end systole was −0.6 ± 0.7 mm (R = 0.95), and −0.5 ± 1.4 mm (R = 0.95) for the left and right ventricle, respectively. Validation of peak emptying velocity, peak filling velocity, and atrial contraction yielded lower accuracy than the displacement measures. The proposed algorithm show good agreement and low bias with the reference standard, and with an agreement in parity with inter-observer variability. Thus, it can be used as an automatic method of tracking and measuring AVPD in CMR.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
KSKatarina Steding-Ehrenborg
Katarina Steding-Ehrenborg
RJRobert Jablonowski
Robert Jablonowski
PAPer M Arvidsson
Per M Arvidsson
MCMarcus Carlsson
Marcus Carlsson
BSBengt Saltin
Bengt Saltin
HAHåkan Arheden
Håkan Arheden
The effects on left and right ventricular (LV, RV) volumes during physical exercise remains controversial. Furthermore, no previous study has investigated the effects of exercise on longitudinal contribution to stroke volume (SV) and the outer volume variation of the heart. The aim of this study was to determine if LV, RV and total heart volumes (THV) as well as cardiac pumping mechanisms change during physical exercise compared to rest using cardiovascular magnetic resonance (CMR).