Sun Do Lim

Dr. Sun Do Lim

Korea Research Institute of Standards and Science (KRISS)
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Optics & Laser Technology
Verified
Journal Article
Closed access
JGJinhwa Gene
Jinhwa Gene
DYDong-Il Yeom
Dong-Il Yeom
SKSeung Kwan Kim
Seung Kwan Kim
Sun Do LimSun Do Lim
Sun Do Lim

19 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MLMa Stella Grace Bada Lequiron
Ma Stella Grace Bada Lequiron
DJDaniel J. Joe
Daniel J. Joe
Sun Do LimSun Do Lim
Sun Do Lim
IDIl Doh
Il Doh
The thermal response time of a thin-film resistance temperature detector (RTD) array sensor was measured for a high-intensity focused ultrasound (HIFU) phantom. As the temperature inside materials change rapidly within several seconds, it is important to have a temperature sensor with a fast response time to evaluate their performance. However, previous methods for measuring thermal response time were not suitable for thin-film sensors, and there were no quantitative data available. In this study, we used a liquid drop method to measure the thermal time constant of the thin-film RTD, which was found to be 1.0 ± 0.2 ms. This indicates that the thin-film RTD array sensor has a sufficiently fast response time to detect sudden temperature changes inside the tissue-mimicking material (TMM) for validating HIFU devices.

16 October 2023 in PhotoniX
Verified
Journal Article
Open access
PDF file
JGJinhwa Gene
Jinhwa Gene
SKSeung Kwan Kim
Seung Kwan Kim
Sun Do LimSun Do Lim
Sun Do Lim
Min Yong JeonMin Yong Jeon
Min Yong Jeon
The maximum peak power of ultrafast mode-locked lasers has been limited by cubic nonlinearity, which collapses the mode-locked pulses and consequently leads to noisy operation or satellite pulses. In this paper, we propose a concept to achieve mode-locked pulses with high peak power beyond the limitation of cubic nonlinearity with the help of dissipative resonance between quintic nonlinear phase shifts and anomalous group velocity dispersion. We first conducted a numerical study to investigate the existence of high peak power ultrafast dissipative solitons in a fiber cavity with anomalous group velocity dispersion (U-DSAD) and found four unique characteristics. We then built long cavity ultrafast thulium-doped fiber lasers and verified that the properties of the generated mode-locked pulses match well with the U-DSAD characteristics found in the numerical study. The best-performing laser generated a peak power of 330 kW and a maximum pulse energy of 80 nJ with a pulse duration of 249 fs at a repetition rate of 428 kHz. Such a high peak power exceeds that of any previous mode-locked pulses generated from a single-mode fiber laser without post-treatment. We anticipate that the means to overcome cubic nonlinearity presented in this paper can give insight in various optical fields dealing with nonlinearity to find solutions beyond the inherent limitations.

26 March 2014 in Physiological Measurement
Verified
Journal Article
Closed access
GKGen Jung Kim
Gen Jung Kim
YYYong Shim Yoo
Yong Shim Yoo
BKBong Hak Kim
Bong Hak Kim
Sun Do LimSun Do Lim
Sun Do Lim
JSJong Hyun Song
Jong Hyun Song
A small-size transfer blackbody cavity for calibration of infrared ear thermometers (IRETs) was developed and characterized at the Korea Research Institute of Standards and Science. This blackbody cavity consists of a reflector exposed to the air and a radiator with three-step curves immersed in a water-bath, and has an angularly uniform emissivity of higher than 0.9993. The radiance temperature of the blackbody cavity was measured with an IRET. We also calculated the effective emissivity by using the software STEEP322, considering the influence of the shape and temperature of the probe-tip of the IRET on the effective emissivity of the blackbody cavity. The measured and calculated radiance temperatures of the blackbody cavity were compared to those of the ASTM-type blackbody cavity and are in good agreement. Uncertainties (k = 1) of the blackbody cavity are estimated to be less than 44 mK in the temperature range 35-42 °C.

23 June 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
SKSeung Kwan Kim
Seung Kwan Kim
DLDong-Joon Lee
Dong-Joon Lee
Sun Do LimSun Do Lim
Sun Do Lim
YHYoung-Pyo Hong
Young-Pyo Hong
NKNo-Weon Kang
No-Weon Kang
Fabrication method of a fiber optic electric field sensing probe using polarization maintaining fiber (PMF) is described including a birefringent axes aligning system. The sensing probe is basically a fiber-coupled Fabry-Perot resonator where a thin birefringent wafer of LiTaO 3 with an external cavity is mounted onto the end of PMF. An optical wave from a superluminescent laser diode after a linear polarizer parallel to the slow axis of the PMF is made to enter the LiTaO 3 crystal with polarization parallel to its extraordinary axis and the reflected optical wave is detected after passing through a polarization analyzer. By measuring a minimum value of a ratio of the reflected optical power at 90° to that of 0° of analyzer, we successfully demonstrated that the angular accuracy of the slow axis of the PMF with respect to the extraordinary axis of the LiTaO 3 can be evaluated. Aligning both axes precisely, the electro-optic effect associated with LiTaO 3 and polarization is optimized with greater stability. Long term stability of the fabricated PMF sensing probe was enhanced by about 3 times compared to that of a conventional single mode fiber one. As a result of uncertainty analysis, the method we proposed has an overall angular uncertainty of 1° when the used fiber optic components have polarization angle tolerance of 1°.

7 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Jinhwa GeneJinhwa Gene
Jinhwa Gene
Min Yong JeonMin Yong Jeon
Min Yong Jeon
Sun Do LimSun Do Lim
Sun Do Lim
We demonstrated spectral reflectometers for two types of reflectances, absolute and relative, of diffusely reflecting surfaces in directional-hemispherical geometry. Both are built based on the integrating sphere method with a Fourier-transform infrared spectrometer operating in a vacuum. The third Taylor method is dedicated to the reflectometer for absolute reflectance, by which absolute spectral diffuse reflectance scales of homemade reference plates are realized. With the reflectometer for relative reflectance, we achieved spectral diffuse reflectance scales of various samples including concrete, polystyrene, and salt plates by comparing against the reference standards. We conducted ray-tracing simulations to quantify systematic uncertainties and evaluated the overall standard uncertainty to be 2.18% (k = 1) and 2.99% (k = 1) for the absolute and relative reflectance measurements, respectively.