Lingjian Zhu

Dr. Lingjian Zhu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
ZOZhenzhen Ou
Zhenzhen Ou
FGFeng Gao
Feng Gao
HZHuaijun Zhao
Huaijun Zhao
SDShumeng Dang
Shumeng Dang
LZLingjian Zhu
Lingjian Zhu
The present work aims at studying the thermal and dielectric properties of addition-cure liquid silicone rubber (ALSR) matrix composites using boron nitride (BN) and aluminum nitride (AlN) as a hybrid thermal conductive filler. Composite samples with different filler contents were fabricated, and the density, thermal conductivity, thermal stability, dielectric properties, and volume resistivity of the samples were measured. According to the experimental results, the density, thermal conductivity, dielectric constant and dielectric loss tangent values all increased with the increasing addition of filler. When the weight fraction of hBN filler was 50 wt%, the thermal conductivity of composites was 0.554 W (m−1 K−1), which is 3.4 times higher than that of pure ALSR. The corresponding relative permittivity and dielectric loss were 3.98 and 0.0085 at 1 MHz, respectively. Furthermore, TGA results revealed that the AlN/BN hybrid filler could also improve the thermal stability of ALSR. The volume resistivity of ALSR composites was higher than that of pure ALSR. The addition of fillers improved the thermal properties of ALSR and had little effect on its insulation properties. This characteristic makes ALSR composites attractive in the field of insulating materials.

25 February 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ELEhtisham Lodhi
Ehtisham Lodhi
FWFei-Yue Wang
Fei-Yue Wang
Gang XiongGang Xiong
Gang Xiong
LZLingjian Zhu
Lingjian Zhu
TTTariku Sinshaw Tamir
Tariku Sinshaw Tamir
MKMuhammad Adil Khan
Muhammad Adil Khan
The widespread adoption of green energy resources worldwide, such as photovoltaic (PV) systems to generate green and renewable power, has prompted safety and reliability concerns. One of these concerns is fault diagnostics, which is needed to manage the reliability and output of PV systems. Severe PV faults make detecting faults challenging because of drastic weather circumstances. This research article presents a novel deep stack-based ensemble learning (DSEL) approach for diagnosing PV array faults. The DSEL approach compromises three deep-learning models, namely, deep neural network, long short-term memory, and Bi-directional long short-term memory, as base learners for diagnosing PV faults. To better analyze PV arrays, we use multinomial logistic regression as a meta-learner to combine the predictions of base learners. This study considers open circuits, short circuits, partial shading, bridge, degradation faults, and incorporation of the MPPT algorithm. The DSEL algorithm offers reliable, precise, and accurate PV-fault diagnostics for noiseless and noisy data. The proposed DSEL approach is quantitatively examined and compared to eight prior machine-learning and deep-learning-based PV-fault classification methodologies by using a simulated dataset. The findings show that the proposed approach outperforms other techniques, achieving 98.62% accuracy for fault detection with noiseless data and 94.87% accuracy with noisy data. The study revealed that the DSEL algorithm retains a strong generalization potential for detecting PV faults while enhancing prediction accuracy. Hence, the proposed DSEL algorithm detects and categorizes PV array faults more efficiently, reliably, and accurately.

5 June 2018 in International Journal of Modern Physics B
Verified
Journal Article
Open access
MBMinyu Bai
Minyu Bai
YZYulong Zhao
Yulong Zhao
BJBinbin Jiao
Binbin Jiao
LZLingjian Zhu
Lingjian Zhu
GZGuodong Zhang
Guodong Zhang
LWLei Wang
Lei Wang
Ion implantation is widely utilized in microelectromechanical systems (MEMS), applied for embedded lead, resistors, conductivity modifications and so forth. In order to achieve an expected device, the principle of ion implantation must be carefully examined. The elementary theory of ion implantation including implantation mechanism, projectile range and implantation-caused damage in the target were studied, which can be regarded as the guidance of ion implantation in MEMS device design and fabrication. Critical factors including implantations dose, energy and annealing conditions are examined by simulations and experiments. The implantation dose mainly determines the dopant concentration in the target substrate. The implantation energy is the key factor of the depth of the dopant elements. The annealing time mainly affects the repair degree of lattice damage and thus the activated elements’ ratio. These factors all together contribute to ions’ behavior in the substrates and characters of the devices. The results can be referred to in the MEMS design, especially piezoresistive devices.

1 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZOZhenzhen Ou
Zhenzhen Ou
FGFeng Gao
Feng Gao
LZLingjian Zhu
Lingjian Zhu
HZHuaijun Zhao
Huaijun Zhao
ZXZihan Xun
Zihan Xun
In view of the development direction of high power and miniaturization of high-voltage power supply, higher requirements are put forward for the breakdown strength, thermal conductivity of packaging materials for its high voltage output module. An electric-insulated heat-conducted material with aluminium nitride as heat conducting filler and addition-cure liquid silicone rubber (ALSR) as matrix for high voltage power encapsulation has been studied. Initially, the thermal conductivity and breakdown strength of composites were explored at different filler fractions. With increase of filler fraction, the thermal conductivity increased and the breakdown strength decreased. Then, with the packaging module volume as the optimization objective and the working temperature as the optimization condition, the temperature distribution of high voltage power supply was studied by using the finite element method, and 40wt% filling fraction was selected as the optimal ratio. Finally, the actual packaging experiment of the high voltage module is carried out. and the variation of the output voltage and temperature with the working time is obtained. According to the experimental results, the output voltage of the high voltage module is basically stable, and the maximum surface temperature is 40.4°C. The practicability of the electric-insulated heat-conducted material has been proved.

1 December 2015 in Metrology and Measurement Systems
Verified
Journal Article
Open access
PDF file
MZMin Zhao
Min Zhao
QHQiu-Hong Huang
Qiu-Hong Huang
LZLingjian Zhu
Lingjian Zhu
ZQZong-Ming Qiu
Zong-Ming Qiu
In order to calibrate the stripe precision of a leveling rod, an automatic laser interferometer and a vision measurement system were designed by Xi’an University of Technology in China. The rod was driven by a closed-loop control and the data were collected at the stop state to ensure precision. The laser interferometer provided not only the long distance data but also a position feedback signal in the automatic control loop. CCD camera and a vision measurement method were used to inspect the stripe edge position and defect. A pixel-equivalent self-calibration method was designed to improve precision. ROI (regions of interest) method and an outline tracing method were designed to quickly extract multiple stripe edges. A combination of the image data with the interferometer data reduces control difficulty and ensures the measurement accuracy. The vision measurement method reached sub-pixel precision and the defective edges were reported. The system can automatically calibrate a stripe leveling rod with a high degree of efficiency and precision.

19 October 2023 in Electronics
Verified
Journal Article
Open access
PDF file
LZLingjian Zhu
Lingjian Zhu
LLLi Lin
Li Lin
QLQi Liang
Qi Liang
YLYaling Lu
Yaling Lu
HTHaonan Tan
Haonan Tan
DZDongya Zhang
Dongya Zhang
In this study, a novel algorithm for optimizing the coverage of directed sensor networks is proposed. The deployment of sensor networks is typically random, leading to the potential issues of extensive coverage overlaps and blind areas. To address this challenge and enhance the effectiveness of network coverage, a directional sensor network coverage optimization algorithm is developed based on the principles of virtual force and particle swarm optimization. Firstly, the article introduces the concept of a segmented virtual negative centroid model. This model revolutionizes the configuration of the virtual negative centroid, thereby enabling a more efficient adjustment of the gravitational forces exerted by the coverage blind areas on the sensor nodes. Therefore, the influence of these blind areas on the improvement of network coverage is significantly amplified. Secondly, taking into account the characteristics of global optimization and the inherent randomness of particle swarm optimization, the algorithm synergistically combines the principles of virtual force and particle swarm optimization. This integration effectively fine-tunes the sensing direction of the sensor nodes, thereby optimizing their overall performance. The algorithm in this study incorporates an adjusted inertia weight strategy and introduces Gaussian disturbance in the local optimization enhancement phase to prevent local optimization, accelerate particle convergence, and facilitate the sensor network’s attainment of an optimal distribution for coverage optimization. Simulation experiments were conducted to verify the algorithm’s effectiveness. The initial sensor network coverage was 31.04%. After applying the algorithm, the average coverage increased to 80.16%, with a maximum coverage of 84.2%. These results verify the effectiveness of the algorithm.