Michael McGinley

Mr. Michael McGinley

St. Croix Sensory, Inc.

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
ABAnna bokowa
Anna bokowa
CDCarlos Diaz
Carlos Diaz
Jacek A. KozielJacek A. Koziel
Jacek A. Koziel
MMMichael McGinley
Michael McGinley
JBJennifer Barclay
Jennifer Barclay
LWLandon Wahe
Landon Wahe
When it comes to air pollution complaints, odours are often the most significant contributor. Sources of odour emissions range from natural to anthropogenic. Mitigation of odour can be challenging, multifaceted, site-specific, and is often confounded by its complexity—defined by existing (or non-existing) environmental laws, public ordinances, and socio-economic considerations. The objective of this paper is to review and summarise odour legislation in selected European countries (France, Germany, Austria, Hungary, the UK, Spain, the Netherlands, Italy, Belgium), North America (the USA and Canada), and South America (Chile and Colombia), as well as Oceania (Australia and New Zealand) and Asia (Japan, China). Many countries have incorporated odour controls into their legislation. However, odour-related assessment criteria tend to be highly variable between countries, individual states, provinces, and even counties and towns. Legislation ranges from (1) no specific mention in environmental legislation that regulates pollutants which are known to have an odour impact to (2) extensive details about odour source testing, odour dispersion modelling, ambient odour monitoring, (3) setback distances, (4) process operations, and (5) odour control technologies and procedures. Agricultural operations are one specific source of odour emissions in rural and suburban areas and a model example of such complexities. Management of agricultural odour emissions is important because of the dense consolidation of animal feeding operations and the advance of housing development into rural areas. Overall, there is a need for continued survey, review, development, and adjustment of odour legislation that considers sustainable development, environmental stewardship, and socio-economic realities, all of which are amenable to a just, site-specific, and sector-specific application.

1 August 2004 in Water Science & Technology
Verified
Journal Article
Closed access
PDF file
MMMichael McGinley
Michael McGinley
CMC.M. McGinley
C.M. McGinley
A standard method for measuring and quantifying odour in the ambient air utilizes a portable odour detecting and measuring device known as a field olfactometer (US Public Health Service Project Grant A-58-541). The field olfactometer dynamically dilutes the ambient air with carbon-filtered air in distinct ratios known as “Dilutions-to-Threshold” dilution factors (D/Ts), i.e. 2, 4, 7, 15, etc. Thirteen US states and several cities in North America currently utilize field olfactometry as a key component of determining compliance to odour regulations and ordinances. A controlled environmental chamber was utilized, with hydrogen sulfide as the known test odorant. A hydrogen sulfide environment was created in this controlled chamber using an Advanced Calibration Designs, Inc. Cal2000 Hydrogen Sulfide Generator. The hydrogen sulfide concentration inside the chamber was monitored using an Arizona Instruments, Inc. Jerome Model 631 H2S Analyzer. When the environmental chamber reached a desired test concentration, test operators entered the chamber. The dilution-to-threshold odour concentration was measured using a Nasal Ranger Field Olfactometer (St Croix Sensory, Inc.) and a Barnebey Sutcliffe Corp. Scentometer. The actual hydrogen sulfide concentration was also measured at the location in the room where the operators were standing while using the two types of field olfactometers. This paper presents a correlation between dilution-to-threshold values (D/T) and hydrogen sulfide ambient concentration. For example, a D/T of 7 corresponds to ambient H2S concentrations of 5.7-15.6 μg/m3 (4-11 ppbv). During this study, no significant difference was found between results obtained using the Scentometer or the Nasal Ranger® (r = 0.82). Also, no significant difference was found between results of multiple Nasal Ranger® users (p = 0.309). The field olfactometers yielded hydrogen sulfide thresholds of 0.7-3.0 μg/m3 (0.5-2.0 ppbv). Laboratory olfactometry yielded comparable thresholds of 0.64-1.3 μg/m3 (0.45-0.9 ppbv). These thresholds are consistent with published values.