Yichen Zhu

Dr. Yichen Zhu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Theranostics
Verified
Journal Article
Open access
YMYouwen Ma
Youwen Ma
MGMingwei Gu
Mingwei Gu
LCLiguo Chen
Liguo Chen
HSHao Shen
Hao Shen
YPYifan Pan
Yifan Pan
LSLining Sun
Lining Sun
The normal development and maturation of oocytes and sperm, the formation of fertilized ova, the implantation of early embryos, and the growth and development of foetuses are the biological basis of mammalian reproduction. Therefore, research on oocytes has always occupied a very important position in the life sciences and reproductive medicine fields. Various embryo engineering technologies for oocytes, early embryo formation and subsequent developmental stages and different target sites, such as gene editing, intracytoplasmic sperm injection (ICSI), preimplantation genetic diagnosis (PGD), and somatic cell nuclear transfer (SCNT) technologies, have all been established and widely used in industrialization. However, as research continues to deepen and target species become more advanced, embryo engineering technology has also been developing in a more complex and sophisticated direction. At the same time, the success rate also shows a declining trend, resulting in an extension of the research and development cycle and rising costs. By studying the existing embryo engineering technology process, we discovered three critical nodes that have the greatest impact on the development of oocytes and early embryos, namely, oocyte micromanipulation, oocyte electrical activation/reconstructed embryo electrofusion, and the in vitro culture of early embryos. This article mainly demonstrates the efforts made by researchers in the relevant technologies of these three critical nodes from an engineering perspective, analyses the shortcomings of the current technology, and proposes a plan and prospects for the development of embryo engineering technology in the future.

13 February 2024 in Precision Engineering
Verified
Journal Article
Closed access
YZYue Zhao
Yue Zhao
HWHao Wu
Hao Wu
LZLulu Zheng
Lulu Zheng
YWYangjun Wang
Yangjun Wang
YZYichen Zhu
Yichen Zhu
LCLiguo Chen
Liguo Chen

13 February 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
HHHaibo Huang
Haibo Huang
YPYifan Pan
Yifan Pan
YPYan Pang
Yan Pang
HSHao Shen
Hao Shen
XGXiwei Gao
Xiwei Gao
LSLining Sun
Lining Sun
Biological microdissection has a wide range of applications in the field of molecular pathology. The current laser-assisted dissection technology is expensive. As an economical microdissection method, piezoelectric ultrasonic microdissection has broad application prospects. However, the performance of the current piezoelectric ultrasonic microdissection technology is unsatisfactory. This paper aims to solve the problems of the low dissecting precision and excessive wear of the dissecting needle caused by the harmful lateral vibration of the present piezoelectric ultrasonic microdissection device. A piezoelectric ultrasonic microdissection device based on a novel flexure mechanism is proposed. By analyzing the flexure hinge flexibility, the type of flexure beam and the optimal design parameters are determined. Through harmonic response simulation analysis, the newly designed microdissection device with a vibration-suppressing mechanism achieves the best vibration effect when the driving frequency is 28 kHz. Under this driving frequency, the lateral vibration suppression effect is improved by 68% compared to the traditional effect without vibration suppression. Then, based on 3D printing technology, a prototype of a novel microdissection device is produced, and its performance is tested. Experiments on dissecting needle vibration tests show that the flexure mechanism does indeed suppress the lateral vibration of the needle tip. We conducted various tissue dissection experiments on paraffin tissue sections. First, we determine the optimal dissecting parameters (driving voltage, frequency, feed speed, cutting angle) of the new equipment through various parameter dissecting experiments. Then, we adopt these optimal dissecting parameters to perform three kinds of dissecting experiments on mouse tissue paraffin section (liver, lung, bone), dissecting experiments on tissue sections of different thicknesses (3 μm, 4 μm, 5 μm), sampling and extraction experiments on complete tissue. The new device has a better dissecting performance for paraffin tissue sections below a 5 μm thickness and can complete various dissecting tasks. Finally, we compare the wear of the dissecting needles of the new and old devices after the same dissecting tasks. The results prove that the suppression of harmful lateral vibration not only significantly improves the dissecting effect but also increases the service life and durability of the dissecting needle, which is beneficial for reducing the equipment costs.