Marta Młodawska

Dr. Marta Młodawska

Jan Kochanowski University, Kielce

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
MMMarta Młodawska
Marta Młodawska
JPJustyna Plusajska
Justyna Plusajska
KDKarolina Detka
Karolina Detka
KBKatarzyna Bialek
Katarzyna Bialek
GSGrzegorz Swiercz
Grzegorz Swiercz
Determination of the Bishop score (BS) is a traditional method of assessing the cervix in obstetrics and gynecology. This examination is characterized by subjectivity of assessment and low repeatability. In scientific studies intended to evaluate the results of the procedure based on the initial assessment, it is necessary to find an objective scale based on ultrasonography. We selected five ultrasound parameters, measured with a transvaginal transducer, that are equivalent to the individual BS axes (dilatation assessed in three-dimensional ultrasound (DL), angle of progression (AoP), vagino-cervical angle (VCA), strain elastography using the E-Cervix module, and cervical length (CL)). All selected parameters were characterized by good to excellent repeatability (intraclass correlation coefficient (ICC) = 0.878–0.994) and reproducibility (ICC = 0.826–0.996). Each of the selected parameters significantly correlated with its corresponding BS axis. The highest value of the correlation coefficient was achieved with CL (−0.75) and DL (0.71). Other parameters were characterized by an average to high correlation (AoP and station = 0.69, hardness ratio and consistency = −0.33, position and VCA = −0.38). The best correlation with the sum of the BS points was exhibited by AoP (0.52) and CL (−0.61). The selected ultrasound parameters analogous to the BS axes were characterized by high repeatability and significant correlation with the axes of the original clinical BS. Further research into the predictive properties of a multivariate model based on these parameters is needed.

29 March 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GSGrzegorz Swiercz
Grzegorz Swiercz
AZAnna Zmelonek-Znamirowska
Anna Zmelonek-Znamirowska
KSKarol Szwabowicz
Karol Szwabowicz
JAJustyna Armanska
Justyna Armanska
KDKarolina Detka
Karolina Detka
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
Background: Contemporary diagnostic methods aimed at assessing neonatal outcomes predominantly rely on the medical history of pregnant women. Ideally, universal biomarkers indicating an increased risk of delivering infants in poor clinical condition, with a heightened likelihood of requiring hospitalization in a Neonatal Intensive Care Unit (NICU), would be beneficial for appropriately stratifying pregnant women into a high-risk category. Our study evaluated whether biochemical and ultrasonographical markers universally used in first-trimester screenings for non-heritable chromosomal aberrations could serve this purpose. Methods: This study encompassed 1164 patients who underwent first-trimester screening, including patient history, ultrasound examinations, and biochemical tests for pregnancy-associated plasma protein-A (PAPP-A) and the free beta-HCG subunit (fbHCG), from January 2019 to December 2021. The research concentrated on the correlation between these prenatal test results and neonatal outcomes, particularly Apgar scores, umbilical blood pH levels, and the necessity for NICU admission. Results: In our cohort, neonates scoring lower than 8 on the Apgar scale at birth exhibited lower concentrations of PAPP-A in the first trimester, both in raw and normalized values (PAPP-A MoM 0.93 vs. 1.027, p = 0.032). We also observed a higher pulsatility index in the venous duct in the first trimester in full-term neonates born with <8 points on the Apgar scale. Additionally, newborns born with an umbilical blood pH < 7.2 had lower normalized first-trimester PAPP-A concentrations (0.69 vs. 1.01 MoM, p = 0.04). We also noted that neonates requiring NICU hospitalization post-delivery had lower first-trimester bHCG concentrations (0.93 MoM vs. 1.11 MoM, p = 0.03). However, none of the correlations in our study translated into a robust prognostic ability for predicting dichotomous outcomes. All areas under the curve achieved a value < 0.7. Conclusions: Low concentrations of PAPP-A and free bHCG subunit in the first trimester may be associated with poorer clinical and biochemical conditions in neonates post-delivery. However, the relationship is weak and has limited predictive capability. Further research evaluating these relationships is necessary for the appropriate stratification of pregnant women into high-risk categories for neonatological complications.

24 January 2022 in Pediatric Reports
Verified
Journal Article
Open access
PDF file
MMMarta Młodawska
Marta Młodawska
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
GSGrzegorz Swiercz
Grzegorz Swiercz
RZRafał Zieliński1
Rafał Zieliński1
Objective: The twisting of the umbilical cord around the fetal neck is a common phenomenon in the delivery room, and despite the lack of univocal evidence of its negative impact on perinatal events, it causes anxiety and stress in patients. The aim of the study was to assess the prevalence of nuchal cord and its impact on adverse obstetric and neonatal outcomes. Methods: We conducted a retrospective cohort study. All patients who gave birth in the clinic within one year (n = 1467) were included in the study group. We compared the prevalence of nuchal cord in distinct subgroups of patients. In the next stage, we estimated the chance of specific perinatal outcomes and compared the neonatal outcomes between groups with and without nuchal cord. Results: Nuchal cord was present in 24% of labors. It was twice as common among patients giving birth vaginally (32.14%) than among patients giving birth by a caesarean section (16.78%, p < 0.001). Nuchal cord was also more frequent in births with meconium-stained amniotic fluid (33.88% vs. 23.34%, p = 0.009). In the group of patients with nuchal cord, we observed a slight increase in the risk of a non-reassuring fetal heart rate trace (OR = 1.55, CI 95% 1.02–2.36) as an indication of the completion of labor by caesarean delivery. We did not note an increase in the risk of completing natural childbirth by vacuum extraction. In the group of nuchal cord patients, there was a higher chance of a serious or moderate neonatal condition in the first minute of life (Apgar 0–7 points) (OR = 2.00, 95% CI = 1.14–3.49). Conclusions: Nuchal cord increases the risk of a caesarean delivery due to a non-reassuring fetal heart rate trace. Nuchal cord increases the chance of a reduced Apgar score (0–7 points) in the first minute of life. The observed relationships do not translate to neonatal arterial blood gas testing.

1 September 2020 in Journal of Pregnancy
Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
MMMarta Młodawska
Marta Młodawska
GJGaluszewska Jagoda
Galuszewska Jagoda
GKGlijer Kamila
Glijer Kamila
SGStanislaw Gluszek
Stanislaw Gluszek
Cervical assessment on the Bishop scale prior to induction of labor (IOL) is one of the strongest prognostic criteria in relation to the success of the procedure. The commonly used preinduction methods are mainly aimed at reducing the percentage of cesarean sections. Our study has analyzed obstetric results of patients who had unripe cervix (Bishop score = 7 points) where preinduction was not used. Patients in group A were more likely to complete the delivery by caesarean section (OR=4.58, 95% CI 3.22-6.51), and more likely to have events that were indications for operative delivery: unreassuring fetal heart rate trace (OR=3.29, 95% CI 2.07-5.23) and arrested labor or failed induction (OR=3.4, 95% CI 2.06-5.62). The groups did not differ in the percentage of vacuum extraction, postpartum haemorrhage, and meconium stained amniotic fluid. In group B, more infants were born with umbilical cord blood pH <7.1 (1.38% vs. 0%), both groups included no deliveries of newborns with Apgar score <= 3 points, the groups did not differ in terms of the percentage of newborns with Apgar score between 4 and 7 at birth (OR=0.66, 95% CI 0.29-1.49). The immature cervix and the need to use labor preinduction is a risk factor for caesarean section. The necessity of preinduction does not impair neonatological results.

Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
AZAnna Zmelonek-Znamirowska
Anna Zmelonek-Znamirowska
ŁPŁukasz Pawlik
Łukasz Pawlik
MMMarta Młodawska
Marta Młodawska
GSGrzegorz Swiercz
Grzegorz Swiercz
Background/Objectives: Functional assessment of the fetal heart remains a significant challenge in contemporary perinatology due to the absence of a universally accepted gold standard for such evaluations. The aim of this study was to evaluate the reproducibility of parameters derived from two-dimensional speckle-tracking echocardiography (2D STE) using the FetalHQ software. Methods: We enrolled 87 pregnant women between 19 and 23 weeks of gestation who were undergoing mid-trimester screening at the Provincial Hospital Complex in Kielce. Two independent operators acquired 5 s cine-loops of four-chamber views (4CVs) according to a standardized protocol. Reproducibility was assessed by examining intra- and interobserver variability using the intraclass correlation coefficient (ICC) for several cardiac parameters, including the global sphericity index (GSI), global longitudinal strain (GLS), stroke volume (SV), and fractional area change (FAC). Results: Reproducibility varied substantially across the assessed parameters. The highest intraobserver reproducibility was observed for the 4CV GSI (ICC > 0.9). Moderate intraobserver reproducibility (ICCs ranging from 0.5 to 0.75) was noted for left ventricular (LV) parameters, such as end-diastolic area, end-systolic area, end-diastolic volume, and end-systolic volume. Interobserver variability demonstrated higher ICC values, with excellent reproducibility (ICC > 0.9) for the 4CV GSI and LV volume measurements. Good reproducibility (ICCs between 0.75 and 0.9) was observed for specific left ventricular segmental strain indices, whereas other parameters showed moderate to poor reproducibility (ICC < 0.5). Conclusions: Two-dimensional speckle-tracking echocardiography (2D STE) using FetalHQ exhibits variable reproducibility, which is influenced by the choice of parameters, operator experience, and technical factors. This method holds potential for fetal cardiac assessment; however, additional research is required to improve its predictive accuracy and streamline the evaluation process for routine clinical application.

6 July 2023 in American Journal of Case Reports
Verified
Journal Article
Open access
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
AKAgnieszka Kardas-Jarząbek
Agnieszka Kardas-Jarząbek
MMMarta Młodawska
Marta Młodawska
GSGrzegorz Swiercz
Grzegorz Swiercz
BACKGROUND Tubal heterotopic pregnancy is an extremely rare complication of pregnancy, in which there is a simultaneous presence of a pregnancy in the uterine cavity and in an ectopic location, most commonly in the fallopian tube. The management of such cases is not clearly established. In the case of a desire to maintain an intrauterine pregnancy, the surgical procedure consisting of a salpingectomy or salpingostomy is the most common. Such a procedure is effective, but it involves potential complications typical of surgeries, so, in some cases, it seems reasonable to apply the expectant management. CASE REPORT A 31-year-old woman was admitted to the clinic due to pain in the right lower abdomen. An ultrasound examination revealed a gestational sac in the uterine cavity corresponding to 5 weeks of pregnancy with a yolk sac. A twin sac was found in the right fallopian tube. Due to the patient's mild symptoms, absence of bleeding into the peritoneal cavity, concerns about the safety of the embryo and the pregnant woman in case of surgery, conservative management was decided. On the 20th day, the patient was discharged from the clinic with a viable intrauterine pregnancy and a partially absorbed ectopic pregnancy. CONCLUSIONS In the case of an ectopic tubal pregnancy, if there are no symptoms of bleeding into the peritoneal cavity, it is possible to adopt a safe conservative approach with strict patient observation.