Jakub Mlodawski

Dr. Jakub Mlodawski

Jan Kochanowski University, Kielce, Świętokrzyskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
MMMarta Młodawska
Marta Młodawska
JPJustyna Plusajska
Justyna Plusajska
KDKarolina Detka
Karolina Detka
KBKatarzyna Bialek
Katarzyna Bialek
GSGrzegorz Swiercz
Grzegorz Swiercz
Determination of the Bishop score (BS) is a traditional method of assessing the cervix in obstetrics and gynecology. This examination is characterized by subjectivity of assessment and low repeatability. In scientific studies intended to evaluate the results of the procedure based on the initial assessment, it is necessary to find an objective scale based on ultrasonography. We selected five ultrasound parameters, measured with a transvaginal transducer, that are equivalent to the individual BS axes (dilatation assessed in three-dimensional ultrasound (DL), angle of progression (AoP), vagino-cervical angle (VCA), strain elastography using the E-Cervix module, and cervical length (CL)). All selected parameters were characterized by good to excellent repeatability (intraclass correlation coefficient (ICC) = 0.878–0.994) and reproducibility (ICC = 0.826–0.996). Each of the selected parameters significantly correlated with its corresponding BS axis. The highest value of the correlation coefficient was achieved with CL (−0.75) and DL (0.71). Other parameters were characterized by an average to high correlation (AoP and station = 0.69, hardness ratio and consistency = −0.33, position and VCA = −0.38). The best correlation with the sum of the BS points was exhibited by AoP (0.52) and CL (−0.61). The selected ultrasound parameters analogous to the BS axes were characterized by high repeatability and significant correlation with the axes of the original clinical BS. Further research into the predictive properties of a multivariate model based on these parameters is needed.

13 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GSG. Swiercz
G. Swiercz
AZA. Zmelonek-Znamirowska
A. Zmelonek-Znamirowska
KSK. Szwabowicz
K. Szwabowicz
JAJ. Armanska
J. Armanska
KDK. Detka
K. Detka
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
In this investigation, we explored the correlation between first-trimester biochemical markers and the incidence of preterm birth (PTB), irrespective of the cause, spontaneous preterm birth (sPTB), and preterm premature rupture of membranes (pPROM) within a cohort comprising 1164 patients. It was discovered that diminished levels of Pregnancy-Associated Plasma Protein-A (PAPP-A) between 11 and 13 + 6 weeks of gestation significantly contributed to the risk of preterm deliveries both before 35 and 37 weeks, as well as to pPROM instances. Furthermore, women experiencing sPTB before the 37th week of gestation also exhibited lower concentrations of PAPP-A. Moreover, reduced first-trimester concentrations of free beta-human chorionic gonadotropin (fb-HCG) were identified as a risk factor for deliveries preceding 37 weeks, pPROM, and sPTB before 35 weeks of gestation. Despite these correlations, the area under the curve for these biochemical markers did not surpass 0.7, indicating their limited diagnostic potential. The most significant discriminatory capability was noted for PAPP-A levels, with a threshold of < 0.71 multiples of the median (MoM) predicting PTB before 37 weeks, yielding an odds ratio of 3.11 (95% Confidence Interval [CI] 1.97–4.92). For sPTB, the greatest discriminatory potential was observed for PAPP-A < 0.688, providing an OR of 2.66 (95% CI 1.51–4.66). The cut-off points corresponded to accuracies of 76.05% and 79.1%, respectively. In regression analyses, the combined predictive models exhibited low explanatory power with R2 values of 9.2% for PTB and 7.7% for sPTB below 35 weeks of gestation. In conclusion, while certain biochemical markers demonstrated associations with outcomes of preterm birth, their individual and collective predictive efficacies for foreseeing such events were found to be suboptimal.

8 December 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
MMMarta Mlodawska
Marta Mlodawska
JPJustyna Plusajska
Justyna Plusajska
KDKarolina Detka
Karolina Detka
AMAgata Michalska
Agata Michalska
MSMarek Sikorski
Marek Sikorski
Strain elastography of the uterine cervix may be useful in the diagnosis and prediction of obstetric complications. The inability to obtain quantitative results, with only the possibility of visual semiquantitative evaluation of the obtained elastograms, has been the limitation of the method thus far. E-Cervix is a software program that uses intrinsic compression to excite tissue and allows the evaluation of quantitative parameters on the basis of pixel distribution in an elastogram. The aim of this study was to assess the repeatability and reproducibility of quantitative cervical strain elastography (E-Cervix) of the uterine cervix and to assess the correlation of the obtained parameters with selected clinical features of patients in the third trimester of pregnancy. In total, 222 patients participated in the study. We assessed 5 ultrasound parameters: elasticity index (ECI), hardness ratio (HR), internal os strain (IOS), external os strain (EOS) and IOS/EOS ratio. Each study was performed according to a predetermined standardized protocol. For all assessed elastographic parameters, we obtained good intra- and interobserver reproducibility. The interclass correlation coefficient (ICC) ranged from 0.77 to 0.838 for intraobserver variability and from 0.771 to 0.826 for interobserver variability. We demonstrated a significant correlation of some obtained elastographic parameters with the basic clinical features of patients, such as age, the number of previous caesarean sections, pregnancy weight and BMI. In each case, the correlation was very low. Quantitative elastographic assessment with the use of E-Cervix is characterized by good repeatability. Some clinical features may affect the value of the parameters obtained. The clinical relevance of this interference requires further investigation.

31 December 2019 in Ginekologia Polska
Verified
Journal Article
Open access
PDF file
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
MMMarta Mlodawska
Marta Mlodawska
GPGrazyna Pazera
Grazyna Pazera
WMWojciech Michalski
Wojciech Michalski
TDTomasz Domanski
Tomasz Domanski
WRWojciech Rokita
Wojciech Rokita
Cerebral palsy is a disease that puts a great mental burden on caregivers and generates very high social costs. Children with CP require many years of rehabilitation and medical care. The etiology of the disease is undoubtedly multifactorial, and the pathogenesis is associated with focal damage to the central nervous system. One can find descriptions of well-documented interventions in the literature that reduce the risk of CP in certain groups of pregnant and neonatal patients, and interventions that have a potentially protective effect. In this review, we have analyzed the available literature in terms of prenatal and postnatal interventions that may have an impact on reducing the incidence of this condition in children. Cerebral palsy is a disease that puts a great mental burden on caregivers and generates very high social costs. Children with CP require many years of rehabilitation and medical care. The etiology of the disease is undoubtedly multifactorial, and the pathogenesis is associated with focal damage to the central nervous system. One can find descriptions of well-documented interventions in the literature that reduce the risk of CP in certain groups of pregnant and neonatal patients, and interventions that have a potentially protective effect. In this review, we have analyzed the available literature in terms of prenatal and postnatal interventions that may have an impact on reducing the incidence of this condition in children.

Verified
Journal Article
Open access
PDF file
DWDamian Warzecha
Damian Warzecha
JZJulia Załęcka
Julia Załęcka
GMGrzegorz Mańka
Grzegorz Mańka
MKMariusz Kiecka
Mariusz Kiecka
MLMichal Lipa
Michal Lipa
PLPiotr Laudanski
Piotr Laudanski
Laparoscopy as a diagnostic tool for patients with suspected endometriosis is associated with several potentially life-threatening complications. Therefore, it is imperative to identify reliable, non-invasive biomarkers of the disease. The aim of this study was to analyse the concentrations of fibronectin and type IV collagen in peritoneal fluid and plasma to assess their role as potential biomarkers in the diagnosis of endometriosis. Fibronectin and collagen IV protein levels were assessed by surface plasmon resonance imaging (SPRi) biosensors with the usage of monoclonal antibodies. All patients enrolled in the study were referred for laparoscopy for the diagnosis of infertility or chronic pelvic pain (n = 84). The study group included patients with endometriosis confirmed during surgery (n = 49). The concentration of fibronectin in the plasma (329.3 ± 98.5 mg/L) and peritoneal fluid (26.8 ± 11.1 μg/L) in women with endometriosis was significantly higher than in the control group (251.2 ± 84.0 mg/L, 7.0 ± 5.9 μg/L). Fibronectin levels were independent of endometriosis stage (p = 0.874, p = 0.469). No significant differences were observed in collagen IV levels (p = 0.385, p = 0.465). The presence of elevated levels of fibronectin may indicate abnormalities in cell–ECM signalling during the course of endometriosis, and may be a potential biomarker for early detection.

29 March 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GSGrzegorz Swiercz
Grzegorz Swiercz
AZAnna Zmelonek-Znamirowska
Anna Zmelonek-Znamirowska
KSKarol Szwabowicz
Karol Szwabowicz
JAJustyna Armanska
Justyna Armanska
KDKarolina Detka
Karolina Detka
Jakub MlodawskiJakub Mlodawski
Jakub Mlodawski
Background: Contemporary diagnostic methods aimed at assessing neonatal outcomes predominantly rely on the medical history of pregnant women. Ideally, universal biomarkers indicating an increased risk of delivering infants in poor clinical condition, with a heightened likelihood of requiring hospitalization in a Neonatal Intensive Care Unit (NICU), would be beneficial for appropriately stratifying pregnant women into a high-risk category. Our study evaluated whether biochemical and ultrasonographical markers universally used in first-trimester screenings for non-heritable chromosomal aberrations could serve this purpose. Methods: This study encompassed 1164 patients who underwent first-trimester screening, including patient history, ultrasound examinations, and biochemical tests for pregnancy-associated plasma protein-A (PAPP-A) and the free beta-HCG subunit (fbHCG), from January 2019 to December 2021. The research concentrated on the correlation between these prenatal test results and neonatal outcomes, particularly Apgar scores, umbilical blood pH levels, and the necessity for NICU admission. Results: In our cohort, neonates scoring lower than 8 on the Apgar scale at birth exhibited lower concentrations of PAPP-A in the first trimester, both in raw and normalized values (PAPP-A MoM 0.93 vs. 1.027, p = 0.032). We also observed a higher pulsatility index in the venous duct in the first trimester in full-term neonates born with <8 points on the Apgar scale. Additionally, newborns born with an umbilical blood pH < 7.2 had lower normalized first-trimester PAPP-A concentrations (0.69 vs. 1.01 MoM, p = 0.04). We also noted that neonates requiring NICU hospitalization post-delivery had lower first-trimester bHCG concentrations (0.93 MoM vs. 1.11 MoM, p = 0.03). However, none of the correlations in our study translated into a robust prognostic ability for predicting dichotomous outcomes. All areas under the curve achieved a value < 0.7. Conclusions: Low concentrations of PAPP-A and free bHCG subunit in the first trimester may be associated with poorer clinical and biochemical conditions in neonates post-delivery. However, the relationship is weak and has limited predictive capability. Further research evaluating these relationships is necessary for the appropriate stratification of pregnant women into high-risk categories for neonatological complications.