Lev Ovchinnikov

Mr. Lev Ovchinnikov

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
BOBatyr Osmonov
Batyr Osmonov
LOLev Ovchinnikov
Lev Ovchinnikov
CGChristoforos Galazis
Christoforos Galazis
BEBerik Emilov
Berik Emilov
MKMustafa Karaibragimov
Mustafa Karaibragimov
IGIgor I Goryanin
Igor I Goryanin
The global spread of severe acute respiratory syndrome coronavirus 2, which causes coronavirus disease 2019 (COVID-19), could be due to limited access to diagnostic tests and equipment. Currently, most diagnoses use the reverse transcription polymerase chain reaction (RT-PCR) and chest computed tomography (CT). However, challenges exist with CT use due to infection control, lack of CT availability in low- and middle-income countries, and low RT-PCR sensitivity. Passive microwave radiometry (MWR), a cheap, non-radioactive, and portable technology, has been used for cancer and other diseases’ diagnoses. Here, we tested MWR use first time for the early diagnosis of pulmonary COVID-19 complications in a cross-sectional controlled trial in order to evaluate MWR use in hospitalized patients with COVID-19 pneumonia and healthy individuals. We measured the skin and internal temperature using 30 points identified on the body, for both lungs. Pneumonia and lung damage were diagnosed by both CT scan and doctors’ diagnoses (pneumonia+/pneumonia−). COVID-19 was determined by RT-PCR (covid+/covid−). The best MWR results were obtained for the pneumonia−/covid− and pneumonia+/covid+ groups. The study suggests that MWR could be used for diagnosing pneumonia in COVID-19 patients. Since MWR is inexpensive, its use will ease the financial burden for both patients and countries. Clinical Trial Number: NCT04568525.

23 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Zhuolun LiZhuolun Li
Zhuolun Li
CGChristoforos Galazis
Christoforos Galazis
IPIllarion Popov
Illarion Popov
LOLev Ovchinnikov
Lev Ovchinnikov
TKTatyana Kharybina
Tatyana Kharybina
IGIgor I Goryanin
Igor I Goryanin
Background and Objective: Medical microwave radiometry (MWR) is used to capture the thermal properties of internal tissues and has usages in breast cancer detection. Our goal in this paper is to improve classification performance and investigate automated neural architecture search methods. Methods: We investigated extending the weight agnostic neural network by optimizing the weights using the bi-population covariance matrix adaptation evolution strategy (BIPOP-CMA-ES) once the topology was found. We evaluated and compared the model based on the F1 score, accuracy, precision, recall, and the number of connections. Results: The experiments were conducted on a dataset of 4912 patients, classified as low or high risk for breast cancer. The weight agnostic BIPOP-CMA-ES model achieved the best average performance. It obtained an F1-score of 0.933, accuracy of 0.932, precision of 0.929, recall of 0.942, and 163 connections. Conclusions: The results of the model are an indication of the promising potential of MWR utilizing a neural network-based diagnostic tool for cancer detection. By separating the tasks of topology search and weight training, we can improve the overall performance.

25 July 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Zhuolun LiZhuolun Li
Zhuolun Li
CGChristoforos Galazis
Christoforos Galazis
IPIllarion Popov
Illarion Popov
LOLev Ovchinnikov
Lev Ovchinnikov
SVSergey Vesnin
Sergey Vesnin
IGIgor I Goryanin
Igor I Goryanin
Background and Objective: Medical Microwave Radiometry (MWR) is used to capture the thermal properties of internal tissues and has usages in breast cancer detection. Our goal in this paper is to improve classification performance and investigate automated neural architecture search methods. Methods: We investigate optimizing the weights of a weight agnostic neural network using bi-population covariance matrix adaptation evolution strategy (BIPOP-CMA-ES) once the topology is found. We compare it against a weight agnostic and cascade correlation neural network. Results: The experiments are conducted on a breast cancer dataset of 4912 patients. Our proposed weight agnostic BIPOP-CMA-ES model achieved the best performance. It obtained an F1-score of 0.9225, accuracy of 0.9219, precision of 0.9228, recall of 0.9217 and topology of 153 connections. Conclusions: The results are an indication of the potential of MWR utilizing a neural network-based diagnostic tool for cancer detection. By separating the tasks of topology search and weight training, we are able to improve the overall performance.

19 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
IGIgor I Goryanin
Igor I Goryanin
LOLev Ovchinnikov
Lev Ovchinnikov
SVSergey Vesnin
Sergey Vesnin
YIYuri D. Ivanov
Yuri D. Ivanov
Passive microwave radiometry (MWR) is a measurement technique based on the detection of passive radiation in the microwave spectrum of different objects. When in equilibrium, this radiation is known to be proportional to the thermodynamic temperature of an emitting body. We hypothesize that living systems feature other mechanisms of emission that are based on protein unfolding and water rotational transitions. To understand the nature of these emissions, microwave radiometry was used in several in vitro experiments. In our study, we performed pilot measurements of microwave emissions from egg whites during denaturation induced by ethanol. Egg whites comprise 10% proteins, such as albumins, mucoproteins, and globulins. We observed a novel phenomenon: microwave emissions changed without a corresponding change in the water’s thermodynamic temperature. We also found striking differences between microwave emissions and thermodynamic temperature kinetics. Therefore, we hypothesize that these two processes are unrelated, contrary to what was thought before. It is known that some pathologies such as stroke or brain trauma feature increased microwave emissions. We hypothesize that this phenomenon originates from protein denaturation and is not related to the thermodynamic temperature. As such, our findings could explain the reason for the increase in microwave emissions after trauma and post mortem for the first time. These findings could be used for the development of novel diagnostics methods. The MWR method is inexpensive and does not require fluorescent or radioactive labels. It can be used in different areas of basic and applied pharmaceutical research, including in kinetics studies in biomedicine.

30 September 2020 in medRxiv
Verified
Preprint
Open access
PDF file
BOBatyr Osmonov
Batyr Osmonov
LOLev Ovchinnikov
Lev Ovchinnikov
CGChristoforos Galazis
Christoforos Galazis
BEBerik Emilov
Berik Emilov
MKMustafa Karaibragimov
Mustafa Karaibragimov
IGIgor I Goryanin
Igor I Goryanin
The World Health Organization (WHO) declared COVID-19 as a global pandemic. It becomes clear that the virus is spreading mostly deadly due to limited access to diagnostics tests and equipment. Traditional radiography and CT remain the main methods of the initial examination of the chest organs. Now, most of the diagnostics has been focused on PCR, chest X-Ray/CT manifestations of COVID-19. However, there are problems with CT due to infection control issues, the inefficiencies introduced in CT room decontamination, and lack of CT availability in LMIC (Low Middle Income Countries). Passive microwave radiometry (MWR) is a cheap, non-radioactive and portable technology. It has already been used for diagnostics of cancer, and other diseases. We have tested if MWR could be used for early diagnostics of pulmonary COVID-19 complications. This was a randomized controlled trial (195 subjects) to evaluate the effectiveness of diagnostics using MWR in patients with pneumonia caused by COVID-19 while they are in hospitals of Kyrgyzstan, and healthy individuals. We have measured skin (IR) and internal (MWR) temperatures by recording passive electromagnetic radiation through the chest wall in the projection of the lungs at 30 symmetrical points on both sides. Pneumonia and lung damage were diagnosed by X-RAY/CT scan and doctor final diagnosis (pn+/pn-). COVID-19 was determined by PCR test (covid+/covid-). The best results were obtained between pn-/covid- and pn+/covid+ groups with sensitivity 92% and specificity 75%.Overall, the study suggests that the use of MWR is a convenient and safe method for screening diagnostics in COVID-19 patients with suspected pneumonia. Since MWR is an inexpensive, it will ease the financial burden for both patients and the countries, especially in LMIC Summary statement: Categorization of COVID-19 caused pneumonia suspicion by MWR has good diagnostic perspectives. It could be done in clinics or for mass screening to identify potential COVID-19 patients with lung complications. Background: The use of chest CT for COVID-19 and PCR diagnosis in healthcare settings with limited PCR and CT capacity is controversial. MWR categorization of the level of COVID-19 suspicion of lung complications might improve diagnostic performance. Purpose: To investigate the value of MWR in addition to CT and COVID-19 PCR scans and to determine its diagnostic performance in individuals with COVID-19 symptoms during hospital admission and rehabilitation. Materials and Methods: In this trial (Kyrgyz Committee Clinical Trial Number: 01-2/141 27 May 2020), from June, 1 2020 to August, 1 2020, we performed parallel MWR, PCR and CT tests, for individuals with COVID-19 admitted to the hospital for medical emergencies related to COVID-19 and pneumonia suspicion. Siemens Ecoline CT scanner, and HITACHI, Radnext 50 Chest X-Ray was used. RT-PCR test were done using “DNA technology” company https://www.dna-technology.ru/equipmentpr/nabory-reagentov-dlya-pcr-infekcii-respiratornogo-trakta/sars-cov-2sars-cov ). For MWR and IR measurements RTM-01-RES was used MMWR LTD, UK ( www.mmwr.co.uk ) Results: This was a randomized controlled trial to evaluate the effectiveness of diagnostics of COVID-19 (covid-/covid+) and pneumonia (pn+/pn-) using passive microwave radiometry (MWR) in patients while they are in hospital, and healthy individuals. We have measured internal (MWR) and skin (IR) temperature on 195 subjects. 149 of them were hospitalized with pneumonia symptoms to Medical center of KSMA and BICARD clinic. Pneumonia and lung damage were diagnosed by X-RAY/CT scans and radiologists lung damage assessment (pn+/pn-). COVID-19 was determined by PCR test (covid+/covid-). The best diagnostics results were obtained between pn-/covid- and pn+/covid+ groups with sensitivity 92% and specificity 75%. Conclusion: The study suggests that the use of MWR is a convenient and safe method for screening diagnostics in COVID-19 patients with suspected pneumonia. Since MWR is inexpensive, it will ease the financial burden for both patients and the countries, especially in LMIC.

19 November 2021 in Respirology
Verified
Journal Article
Open access
PDF file
BOBatyr Osmonov
Batyr Osmonov
LOLev Ovchinnikov
Lev Ovchinnikov
CGChristopher Galazis
Christopher Galazis
BEBerik Emilov
Berik Emilov
IGIgor I Goryanin
Igor I Goryanin
MIMuktarbek Iskakov
Muktarbek Iskakov
Click on the article title to read more.