The global spread of severe acute respiratory syndrome coronavirus 2, which causes coronavirus disease 2019 (COVID-19), could be due to limited access to diagnostic tests and equipment. Currently, most diagnoses use the reverse transcription polymerase chain reaction (RT-PCR) and chest computed tomography (CT). However, challenges exist with CT use due to infection control, lack of CT availability in low- and middle-income countries, and low RT-PCR sensitivity. Passive microwave radiometry (MWR), a cheap, non-radioactive, and portable technology, has been used for cancer and other diseases’ diagnoses. Here, we tested MWR use first time for the early diagnosis of pulmonary COVID-19 complications in a cross-sectional controlled trial in order to evaluate MWR use in hospitalized patients with COVID-19 pneumonia and healthy individuals. We measured the skin and internal temperature using 30 points identified on the body, for both lungs. Pneumonia and lung damage were diagnosed by both CT scan and doctors’ diagnoses (pneumonia+/pneumonia−). COVID-19 was determined by RT-PCR (covid+/covid−). The best MWR results were obtained for the pneumonia−/covid− and pneumonia+/covid+ groups. The study suggests that MWR could be used for diagnosing pneumonia in COVID-19 patients. Since MWR is inexpensive, its use will ease the financial burden for both patients and countries. Clinical Trial Number: NCT04568525.
Background and Objective: Medical microwave radiometry (MWR) is used to capture the thermal properties of internal tissues and has usages in breast cancer detection. Our goal in this paper is to improve classification performance and investigate automated neural architecture search methods. Methods: We investigated extending the weight agnostic neural network by optimizing the weights using the bi-population covariance matrix adaptation evolution strategy (BIPOP-CMA-ES) once the topology was found. We evaluated and compared the model based on the F1 score, accuracy, precision, recall, and the number of connections. Results: The experiments were conducted on a dataset of 4912 patients, classified as low or high risk for breast cancer. The weight agnostic BIPOP-CMA-ES model achieved the best average performance. It obtained an F1-score of 0.933, accuracy of 0.932, precision of 0.929, recall of 0.942, and 163 connections. Conclusions: The results of the model are an indication of the promising potential of MWR utilizing a neural network-based diagnostic tool for cancer detection. By separating the tasks of topology search and weight training, we can improve the overall performance.
1 July 2021 in Mathematical Physics and Computer Simulation
This work was done with the aim of developing the fundamental breast cancer early differential diagnosis foundations based on modeling the spacetime temperature distribution using the microwave radiothermometry method and obtained data intelligent analysis. The article deals with the machine learning application in the microwave radiothermometry data analysis. The problems associated with the construction mammary glands temperature fields computer models for patients with various diagnostics classes, are also discussed. With the help of a computer experiment, based on the machine learning algorithms set (logistic regression, naive Bayesian classifier, support vector machine, decision tree, gradient boosting, Knearest neighbors, etc.) usage, the mammary glands temperature fields computer models set adequacy.
Background and Objective: Medical Microwave Radiometry (MWR) is used to capture the thermal properties of internal tissues and has usages in breast cancer detection. Our goal in this paper is to improve classification performance and investigate automated neural architecture search methods. Methods: We investigate optimizing the weights of a weight agnostic neural network using bi-population covariance matrix adaptation evolution strategy (BIPOP-CMA-ES) once the topology is found. We compare it against a weight agnostic and cascade correlation neural network. Results: The experiments are conducted on a breast cancer dataset of 4912 patients. Our proposed weight agnostic BIPOP-CMA-ES model achieved the best performance. It obtained an F1-score of 0.9225, accuracy of 0.9219, precision of 0.9228, recall of 0.9217 and topology of 153 connections. Conclusions: The results are an indication of the potential of MWR utilizing a neural network-based diagnostic tool for cancer detection. By separating the tasks of topology search and weight training, we are able to improve the overall performance.
Breast cancer prevention is an important health issue for women worldwide. In this study, we compared the conventional breast cancer screening exams of mammography and ultrasound with the novel approaches of passive microwave radiometry (MWR) and microRNA (miRNA) analysis. While mammography screening dynamics could be completed in 3–6 months, MWR provided a prediction in a matter of weeks or even days. Moreover, MWR has the potential of being complemented with miRNA diagnostics to further improve its predictive quality. These novel techniques can be used alone or in conjunction with more established techniques to improve early breast cancer diagnosis.
1 July 2024 in Lobachevskii Journal of Mathematics
The study aims to develop effective tools for solving inverse problems of river hydrology through the joint use of hydrodynamic river flow modeling and intelligent computing based on artificial neural networks. The hydrological regime of any river system is determined by the hydraulic resistance to flow, which depends on a large number of physical factors. We have built a set of models with different hydraulic resistance input parameters. The results of hydrodynamic simulations are fitted with a series of measurements of water levels at gauging stations in the Volga River. The use of neural network with the Long Short-Term Memory architecture made it possible to calculate the optimal values of the free parameters that provide the best agreement between the observational data and the results of direct numerical simulation. Our analysis showed that the efficiency of parallelization on \(4\times\textrm{GPUs}\) is in the range of 40–50 percent when simulating flooding of river valleys, when the computational domain is approximately 20–50 percent covered with water layer.