Bo Ram Seol

Dr. Bo Ram Seol

VHS (Veterans Health Service) Medical Center
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Bo Ram SeolBo Ram Seol
Bo Ram Seol
SLSang Yoon Lee
Sang Yoon Lee
YKYu Jeong Kim
Yu Jeong Kim
YKYoung-Kook Kim
Young-Kook Kim
JJJin Wook Jeoung
Jin Wook Jeoung
KPKi Ho Park
Ki Ho Park
(1) Background: Mitomycin C (MMC) is commonly used during trabeculectomy. However, there is no consensus on which concentration should be used. We aimed to compare the efficacy and safety of 0.2 mg/mL and 0.4 mg/mL of MMC in eyes undergoing trabeculectomy. (2) Methods: Thirty-six eyes (36 glaucoma patients) were randomized to undergo a trabeculectomy with 0.2 mg/mL or 0.4 mg/mL of MMC. The success rate was evaluated according to three criteria: (A) intraocular pressure (IOP) ≤ 18 mmHg and IOP reduction ≥ 20%; (B) IOP ≤ 15 mmHg and IOP reduction ≥ 25%; (C) IOP ≤ 12 mmHg and IOP reduction ≥ 30%. Cox’s proportional hazard model was used to identify the predictive factors for failure. Immunohistochemical procedures for matrix metalloproteinase (MMP) were performed on Tenon’s tissue. Bleb morphology was evaluated. Safety was assessed based on the incidence of complications. (3) Results: Of the 36 eyes, 19 underwent trabeculectomy with 0.2 mg/mL of MMC and 17 with 0.4 mg/mL. The success rates were 75%, 67%, and 47% at 6 months for criteria A, B, and C, respectively. There were no significant differences between the two groups. High MMP-9 staining and low preoperative IOP were associated with failure (hazard ratio (HR), 5.556; p = 0.033, and HR, 0.936; p = 0.033). Complications included hypotony in two eyes (6%), hyphema in one eye (3%), and choroidal detachment in one eye (3%). (4) Conclusions: Trabeculectomy with 0.2 mg/mL and 0.4 mg/mL of MMC showed similar IOP-control effects to those recorded in previous studies, along with a low rate of complications. There was no significant difference in efficacy or safety between the 0.2 mg/mL and 0.4 mg/mL MMC groups.

1 March 2019 in Journal of Glaucoma
Verified
Journal Article
Closed access
Bo Ram SeolBo Ram Seol
Bo Ram Seol
JSJoo Young Shin
Joo Young Shin
SCSangkyung Choi
Sangkyung Choi
TKTae Gu Kang
Tae Gu Kang
JJJin Wook Jeoung
Jin Wook Jeoung
KPKi Ho Park
Ki Ho Park
Purpose: To evaluate the early-postoperative intraocular pressure (IOP) changes and frequency of IOP spike after cataract surgery in normal-tension glaucoma (NTG) eyes and to compare them with those of nonglaucomatous eyes. Materials and Methods: This was a case-control study. We reviewed the medical records of patients who had undergone cataract surgery. One-to-one (1:1) case matching was performed, each matched set consisting of 1 NTG and 1 nonglaucomatous eye as the control eye. Comparisons between those 2 groups were performed. Specifically, IOP was measured preoperatively and 1 day, 1, 2, and 4 weeks postoperatively. The incidence of IOP spike was evaluated according to the criteria of IOP higher than 21, 25, 30 mm Hg, higher than 5, 10 mm Hg over baseline IOP, and 50% above preoperative IOP. Results: A total of 298 eyes (149 NTG eyes and 149 control eyes) were enrolled. Preoperative IOP did not show any significant difference between the 2 groups (P=0.687). IOP significantly decreased in both the NTG and control groups [P<0.001, repeated-measures analysis of variance (ANOVA)]. No significant differences in this regard were detected between the 2 groups (P=0.618, repeated-measures ANOVA). When IOP spike was evaluated according to the 6 criteria, the frequencies were <3% at any timepoint. There was no significant difference between the 2 groups. Conclusions: In both the NTG and control groups, IOP gradually decreased in the early-postoperative period after cataract surgery, and there was no significant difference between the 2 groups. The frequency of IOP spike was <5% in both the NTG group and the control group.

16 September 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Bo Ram SeolBo Ram Seol
Bo Ram Seol
TKTae Gu Kang
Tae Gu Kang
BGBonhyeok Gu
Bonhyeok Gu
To investigate intraocular pressure (IOP) readings by non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT) for patients with different degrees of bilateral tearing. In this study, we reviewed the medical charts of patients complaining of different degrees of bilateral tearing. The tear meniscus height (TMH) and IOP with NCT and GAT were measured. In each patient, a comparison of IOP readings between the eye with lower TMH and the contralateral eye with higher TMH was evaluated. The TMH was graded as follows: grade 1 (low): TMH < 0.2 mm; grade 2 (moderate): 0.2 mm ≤ TMH < 0.6 mm; grade 3 (high): TMH ≥ 0.6 mm. Subsequently, a comparison of IOP readings among eyes with low, moderate, and high TMH was also performed. A total of 120 eyes of 60 patients were enrolled. When comparing the two eyes of a patient, the eye with higher TMH showed higher NCT readings and larger difference in IOP readings between the two tonometries than the eye with lower TMH (P < 0.001 and P < 0.001, respectively). When TMH was classified into grades according to the degree, the high TMH eyes showed higher NCT readings than did the low and moderate TMH eyes (P < 0.001 and P = 0.001, respectively). In addition, the high TMH eyes showed a larger difference in IOP readings between the two tonometries than did the low and moderate TMH eyes (P < 0.001 and P < 0.001, respectively). Eyes with higher TMH showed higher NCT readings and a larger difference in IOP between the two tonometries (NCT and GAT) than those with lower TMH. In patients with tearing, the NCT value may be inaccurate, so it is necessary to measure the GAT.

15 December 2023 in Journal of the Korean Ophthalmological Society
Verified
Journal Article
Open access
PDF file
HHHeeyong Han
Heeyong Han
Bo Ram SeolBo Ram Seol
Bo Ram Seol
Purpose: To investigate the effect of an epiretinal membrane (ERM) on peripapillary retinal nerve fiber layer thickness (pRNFLT), macular ganglion cell-inner plexiform layer thickness (mGCIPLT) and macular thickness (MT) in relation to glaucoma severity using swept-source optical coherence tomography (SS-OCT). Methods: In total, 105 eyes of 105 glaucoma patients with ERM were matched at a 1:1 ratio with glaucoma patients without ERM according to age, sex, cataract surgery, axial length and mean deviation based on visual field tests. The differences in pRNFLT, mGCIPLT and MT between the two groups were assessed using SS-OCT. Furthermore, the patients were divided into three glaucoma-severity groups, and the differences in pRNFLT, mGCIPLT and MT were compared between glaucoma patients with and without ERM in each group. Results: In all patients, including those with early, moderate, and advanced glaucoma, those with ERM had greater average, temporal quadrant, and 7, 8, 9, 10, and 11 o'clock pRNFLT values compared to those without ERM. Additionally, mGCIPLT and MT were thicker in glaucoma patients with ERM in all groups. The difference in pRNFLT at the 7 and 11 o'clock positions between glaucoma patients with and without ERM was significantly more pronounced in the moderate glaucoma group than in the early glaucoma group (p = 0.043 and p = 0.012, respectively). Conclusions: ERM has notable effects on the pRNFLT, mGCIPLT and MT. Furthermore, the magnitude of its effect on pRNFLT varies with glaucoma severity.

27 March 2026 in Medicine
Verified
Journal Article
Open access
Bo Ram SeolBo Ram Seol
Bo Ram Seol
JJJin Wook Jeoung
Jin Wook Jeoung
: While a few studies have reported on single nucleotide polymorphisms associated with glaucoma in the Korean population, comprehensive data on genotype-phenotype correlations across multiple candidate genes are lacking. This study aimed to investigate the associations of variants in 10 candidate genes (CDKN2B, SIX1, SIX6, SCYL1, CHEK2, ATOH7, DCLK1, RERE, CDC7, and CARD10) with primary open-angle glaucoma (POAG) susceptibility and structural phenotypic features. We employed a 2-stage study design consisting of a discovery phase (targeted sequencing of 100 subjects) and a confirmation phase (genotyping of 24 selected variants in a total cohort of 382 subjects: 160 POAG cases and 222 controls). Associations with POAG risk and structural parameters, including vertical cup-to-disc ratio and retinal nerve fiber layer thickness (RNFLT), were analyzed using multivariable logistic regression and analysis of variance. The Benjamini–Hochberg false discovery rate method was applied to account for multiple testing. Regarding POAG susceptibility, 3 variants in DCLK1, SIX6, and SCYL1 showed nominal significance in the initial analysis but did not withstand false discovery rate correction. However, regarding phenotypic traits, rs33912345 in SIX6 demonstrated robust significant associations with both increased vertical cup-to-disc ratio and reduced average, superior, temporal and inferior RNFLT. Additionally, rs748189671 in RERE was significantly associated with temporal RNFLT. In detailed clock-hour analysis, variants in DCLK1 and SIX1 also showed significant correlations with 3 o’clock sector of RNFLT. Our findings identify DCLK1, SIX1, SIX6 and RERE as key genetic factors influencing optic nerve morphology and RNFLT in the Korean population. These results suggest that these genes may primarily modulate the structural vulnerability of the optic nerve, highlighting their potential utility for phenotypic profiling of glaucoma in the Korean population. However, these results are exploratory, and further large-scale studies are warranted to validate these associations and elucidate their clinical implications in glaucoma genetics.