Biocompatibility is important for the 3D printing of resins used in medical devices and can be affected by photoinitiators, one of the key additives used in the 3D printing process. The choice of ingredients must be considered, as the toxicity varies depending on the photoinitiator, and unreacted photoinitiator may leach out of the polymerized resin. In this study, the use of ethyl (2,4,6-trimethylbenzoyl) phenylphosphinate (TPO-L) as a photoinitiator for the 3D printing of resin was considered for application in medical device production, where the cytotoxicity, colour stability, dimensional accuracy, degree of conversion, and mechanical/physical properties were evaluated. Along with TPO-L, two conventional photoinitiators, phenylbis (2,4,6-trimethylbenzoyl) phosphine oxide (BAPO) and diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide (TPO), were considered. A total of 0.1 mol% of each photoinitiator was mixed with the resin matrix to prepare a resin mixture for 3D printing. The specimens were printed using a direct light processing (DLP) type 3D printer. The 3D-printed specimens were postprocessed and evaluated for cytotoxicity, colour stability, dimensional accuracy, degree of conversion, and mechanical properties in accordance with international standards and the methods described in previous studies. The TPO-L photoinitiator showed excellent biocompatibility and colour stability and possessed with an acceptable dimensional accuracy for use in the 3D printing of resins. Therefore, the TPO-L photoinitiator can be sufficiently used as a photoinitiator for dental 3D-printed resin.

22 January 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMin-Chae Kim
Min-Chae Kim
DBDa-Jung Byeon
Da-Jung Byeon
EJEo-Jin Jeong
Eo-Jin Jeong
HGHye-bin Go
Hye-bin Go
SYSong-Yi Yang
Song-Yi Yang
Various materials have been introduced for the three-dimensional (3D) printing of dentures. In this study, the color stability and surface and physicochemical properties of 3D-printed denture base resins with four types of nanofiller particles were evaluated. Al2O3, ZnO, CeZr, and SiO2 nanofillers were added to a 3D printable denture base-resin matrix and subjected to digital light processing. The specimens were immersed in Coke, coffee, black tea, or distilled water for 6 days. For the assessment of color differences, 6 samples were analyzed using a spectrophotometer. In a separate investigation, surface properties of 10 samples were examined, while a different set of 6 samples was used to analyze water sorption and solubility. All experimental groups exhibited higher color stability in Coke than the control group. However, the groups containing ZnO and CeZr had lower color stability in coffee and black tea than the control group. Moreover, they had agglomerated nanofillers and lower gloss than the control group. Compared with that of the control group, the contact angle of the CeZr group and microhardness of the ZnO group were not significantly different. Water sorption was higher in the Al2O3 group, whereas the solubility of the experimental and control groups was not statistically significant. The results demonstrated the significant effect of ZnO and CeZr nanofillers on the color stability of the dentures when exposed to discoloring beverages. These results will facilitate the development of fillers that enhance the resistance of 3D printed denture base resins to discoloration in the oral environment.

9 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
HGHye-bin Go
Hye-bin Go
BJBang Jaeyun
Bang Jaeyun
KKKyoung-Nam Kim
Kyoung-Nam Kim
KKKwang-Mahn Kim
Kwang-Mahn Kim
Jae-Sung KwonJae-Sung Kwon
Jae-Sung Kwon
The aim of this study was to investigate the element composition and grain size of commercial dental instruments used for ultrasonic scaler tips, which are composed of stainless-steel materials. The differences in mechanical properties and wear resistances were compared. The samples were classified into 4 groups in accordance with the manufacturer, Electro Medical Systems, 3A MEDES, DMETEC and OSUNG MND, and the element compositions of each stainless-steel ultrasonic scaler tip were analyzed with micro-X-ray fluorescence spectrometry (μXRF) and field-emission scanning electron microscopy (FE-SEM) with energy-dispersive X-ray spectroscopy (EDS). One-way ANOVA showed that there were significant differences in shear strength and Vickers hardness among the stainless-steel ultrasonic scaler tips depending on the manufacturer (p < 0.05). The mass before and after wear were found to have no significant difference among groups (p > 0.05), but there was a significant difference in the wear volume loss (p < 0.05). The results were then correlated with μXRF results as well as observations of grain size with optical microscopy, which concluded that the Fe content and the grain size of the stainless steel have significant impacts on strength. Additionally, stainless-steel ultrasonic scaler tips with higher Vickers hardness values showed greater wear resistance, which would be an important wear characteristic for clinicians to check.

25 February 2026 in International Dental Journal
Verified
Journal Article
Open access
HGHye-bin Go
Hye-bin Go
GKGi-Tae Kim
Gi-Tae Kim
JYJae-Hun Yu
Jae-Hun Yu
YYYoungjae Yoon
Youngjae Yoon
Jae-Sung KwonJae-Sung Kwon
Jae-Sung Kwon
This in vitro study evaluated how 3 sterilization methods-autoclaving, ethylene oxide (EO) gas, and hydrogen peroxide gas plasma-affect the mechanical, physical, and dimensional properties of 3-dimensional (3D) printed implant surgical guides. These techniques are widely used in dental practice but differ in mechanism and limitations. Twenty specimens were fabricated using a digital light processing printer and divided into 4 groups (n = 5): non-sterilized control, autoclaving (121 °C, 15 minutes), EO gas (55 °C, 60 minutes), and hydrogen peroxide gas plasma (<57 °C, 18 minutes). Mechanical tests evaluated flexural strength, modulus, and Shore D hardness while translucency and dimensional stability were also assessed. Shape deviation and implant positioning accuracy were compared before and after sterilization. Data were analyzed with one-way analysis of variance and Tukey's post hoc test. All sterilized groups maintained internal fit deviations within clinically acceptable tolerance (±120 μm), showing no significant differences in overall dimensional accuracy. Implant placement precision was preserved, with implant-tooth distances ≥2 mm. EO sterilization significantly increased the flexural strength (122.49 ± 10.10 MPa) and modulus (3477 ± 161 MPa) compared with controls whereas autoclaving showed the lowest strength (92.40 ± 15.06 MPa). Shore D hardness exceeded 90 HS in all groups, with autoclaving producing the highest values. Only EO treatment significantly reduced translucency. Sterilization method influenced the mechanical and optical properties of 3D-printed surgical guides without compromising dimensional accuracy. The findings provide evidence-based guidance for clinicians to select sterilization protocols that preserve the functionality of 3D-printed surgical guides and ensure precision in implant placement.

17 July 2026 in International Dental Journal
Verified
Journal Article
Open access
EKEun-Ju Kim
Eun-Ju Kim
SKSe-Eun Kim
Se-Eun Kim
YKYe-Jin Kim
Ye-Jin Kim
JKJi-Eun Kim
Ji-Eun Kim
YHYun-Yeong Hwang
Yun-Yeong Hwang
SYSong-Yi Yang
Song-Yi Yang
This study evaluated the effects of acidic immersion conditions on the mechanical properties, colour stability, microhardness, and surface roughness of a three-dimensional (3D) printed denture base resin compared with a conventional autopolymerized resin. Specimens of both materials were immersed for 24 hours at 36°C in solutions with pH values of 1, 3, 5, or 7. Flexural strength and modulus were measured using a three-point bending test, and Vickers hardness, colour stability, surface roughness, and contact angle were evaluated using established laboratory protocols. Surface morphology was examined using scanning electron microscopy to assess microstructural changes under different pH conditions. Two-way ANOVA showed that material type and pH level significantly affected flexural strength, flexural modulus, and Vickers hardness (P < .05), with significant material × pH interactions for flexural modulus and Vickers hardness. The tested 3D-printed resin generally showed higher mechanical properties than the autopolymerized resin under the tested pH conditions. Surface roughness was significantly affected by pH level and increased under lower pH conditions, while scanning electron microscopy qualitatively showed more visible surface irregularities at lower pH values. Colour stability and contact angle were not significantly affected by material type, pH level, or their interaction (P > .05). The tested 3D-printed denture base resin showed more favourable mechanical behaviour than the tested autopolymerized resin under the present acidic conditions. Further studies using broader material formulations and clinically relevant ageing models are needed to validate these findings.

30 September 2026 in Korean Journal of Clinical Dental Hygiene
Verified
Journal Article
Closed access
HCHyunjae Cha
Hyunjae Cha
HGHye-bin Go
Hye-bin Go
JCJun-Hyuk Choi
Jun-Hyuk Choi
Objective: This study examined temporal changes in major satisfaction, career self-understanding behavior, and problem-solving self-efficacy among dental hygiene students during two school-based oral health education field sessions. Methods: This single-group three-wave repeated-measures study included 80 fourth-year dental hygiene students. Data collected before the first field session (T0), after the first session (T1), and after the second session one week later (T2) were analyzed using repeated-measures analysis of variance with Bonferroni-corrected pairwise comparisons and Spearman correlation analysis. Results: Major satisfaction was higher at T1 and T2 than at T0(3.91, 4.06, and 4.06, respectively; p<.001), with no difference between T1 and T2. Career self-understanding behavior showed the same pattern(3.86, 3.98, and 3.97, respectively; p<.001). Problem-solving self-efficacy increased at each time point(3.48, 3.68, and 3.86; p<.001), with significant differences among the three time points. General satisfaction increased across all time points. In contrast, social perception satisfaction differed only between T0 and T1. Curriculum and relationship satisfaction did not change significantly during the study. The changes in the scores were not significantly correlated. Conclusions: Repeated field performances with feedback may have educational value during the field-application stage of school-based oral health education for dental hygiene students.