Structural information derived via ultrasound is utilized as prior information for quantitative microwave imaging. The structural information is extracted from ray-based ultrasound reconstructions using a K-means clustering algorithm, and consists of three tissue regions (skin, adipose, and fibroglandular). Tissue specific complex permittivity values are assigned to each region (i.e., the complex permittivity is homogeneous over each region). The regions are then incorporated as an inhomogeneous numerical background in a quantitative microwave imaging algorithm (Contrast Source Inversion). This new approach is assessed using synthetic data obtained from several anthropomorphic breast models of various densities derived from Magnetic Resonance Imaging breast images, all containing tumors. Imaging results are quantitatively evaluated based on the algorithm's ability to detect the tumors. The performance is tested with four different variations of the prior information: two variations of the structural information and two of the assigned permittivity values. The resulting Ultrasound-Microwave multimodality imaging approach substantially improves the fidelity and accuracy of the reconstructed internal structures relative to previous studies that used radar-based microwave techniques to extract the internal structural information. An improvement in the sensitivity of the imaging algorithm to malignant tissue is also observed.
31 July 2020 in IEEE Transactions on Computational Imaging
A multistage algorithm for quantitative microwave breast imaging is presented which utilizes the eigenfunction-based reconstruction of the complex-valued permittivity as prior information. The eigenfunction-based reconstruction is obtained from a single-frequency non-iterative microwave inversion technique that uses the eigenfunctions of the Helmholtz operator, in a resonant conductive enclosure, as the expansion basis. The low-resolution eigenfunction-based reconstruction is incorporated into the Contrast Source Inversion technique as an inhomogeneous numerical background. The use of this prior information improves the stability of the inversion algorithm and results in better detectability of tumors. The multistage algorithm's performance is demonstrated by applying it to synthetic data obtained from three 2D MRI-derived anthropomorphic breast models with various densities and shapes. The algorithm's efficacy in tumor detection is assessed by investigating detection results using prior information obtained with the number of eigenfunction in the expansion basis truncated with three different values. Numerical experiments are performed using four different frequencies. The main advantage of obtaining prior information using this method, as opposed e.g. in using radar or ultrasound derived prior, is that it utilizes the same microwave set-up and only microwave interrogating fields.
Evaluating the quality of reconstructed images requires consistent approaches to extracting information and applying metrics. Partitioning medical images into tissue types permits the quantitative assessment of regions that contain a specific tissue. The assessment facilitates the evaluation of an imaging algorithm in terms of its ability to reconstruct the properties of various tissue types and identify anomalies. Microwave tomography is an imaging modality that is model-based and reconstructs an approximation of the actual internal spatial distribution of the dielectric properties of a breast over a reconstruction model consisting of discrete elements. The breast tissue types are characterized by their dielectric properties, so the complex permittivity profile that is reconstructed may be used to distinguish different tissue types. This manuscript presents a robust and flexible medical image segmentation technique to partition microwave breast images into tissue types in order to facilitate the evaluation of image quality. The approach combines an unsupervised machine learning method with statistical techniques. The key advantage for using the algorithm over other approaches, such as a threshold-based segmentation method, is that it supports this quantitative analysis without prior assumptions such as knowledge of the expected dielectric property values that characterize each tissue type. Moreover, it can be used for scenarios where there is a scarcity of data available for supervised learning. Microwave images are formed by solving an inverse scattering problem that is severely ill-posed, which has a significant impact on image quality. A number of strategies have been developed to alleviate the ill-posedness of the inverse scattering problem. The degree of success of each strategy varies, leading to reconstructions that have a wide range of image quality. A requirement for the segmentation technique is the ability to partition tissue types over a range of image qualities, which is demonstrated in the first part of the paper. The segmentation of images into regions of interest corresponding to various tissue types leads to the decomposition of the breast interior into disjoint tissue masks. An array of region and distance-based metrics are applied to compare masks extracted from reconstructed images and ground truth models. The quantitative results reveal the accuracy with which the geometric and dielectric properties are reconstructed. The incorporation of the segmentation that results in a framework that effectively furnishes the quantitative assessment of regions that contain a specific tissue is also demonstrated. The algorithm is applied to reconstructed microwave images derived from breasts with various densities and tissue distributions to demonstrate the flexibility of the algorithm and that it is not data-specific. The potential for using the algorithm to assist in diagnosis is exhibited with a tumor tracking example. This example also establishes the usefulness of the approach in evaluating the performance of the reconstruction algorithm in terms of its sensitivity and specificity to malignant tissue and its ability to accurately reconstruct malignant tissue.
1 January 2019 in Progress In Electromagnetics Research B
A non-iterative inverse-source solver is introduced for the 2D Helmholtz boundary value problem (BVP). Microwave imaging within a chamber having electrically conducting walls is formulated as a time-harmonic 2D electromagnetic field problem that can be modelled by such a BVP. The novel inverse-source solver, which solves for contrast sources, is the first step in a two-stage process that recovers the complex permittivity of an object of interest in the second step. The unknown contrast sources, as well as the (permittivity) contrast, are represented using the eigenfunction basis associated with the chamber's shape; canonical shapes allowing for analytically defined eigenfunctions. This wholedomain eigenfunction basis allows the imposition of constraints on the contrast-source expansion at virtual spatial points or contours outside the imaging domain. These constraints effectively regularize the inverse-source problem and the result is a well-conditioned matrix equation for the contrast-source coefficients that is solved in a least-squares sense. The contrast-source coefficients corresponding to different illuminating fields are then utilized to recover the contrast expansion coefficients using one more well-conditioned matrix inversion. The performance of this algorithm is studied using a series of synthetic test problems. The results of this study are promising as they compare very well with, and at times out-perform, state-of-the-art inversion algorithms (both in terms of reconstruction quality and computation time).