Structural information derived via ultrasound is utilized as prior information for quantitative microwave imaging. The structural information is extracted from ray-based ultrasound reconstructions using a K-means clustering algorithm, and consists of three tissue regions (skin, adipose, and fibroglandular). Tissue specific complex permittivity values are assigned to each region (i.e., the complex permittivity is homogeneous over each region). The regions are then incorporated as an inhomogeneous numerical background in a quantitative microwave imaging algorithm (Contrast Source Inversion). This new approach is assessed using synthetic data obtained from several anthropomorphic breast models of various densities derived from Magnetic Resonance Imaging breast images, all containing tumors. Imaging results are quantitatively evaluated based on the algorithm's ability to detect the tumors. The performance is tested with four different variations of the prior information: two variations of the structural information and two of the assigned permittivity values. The resulting Ultrasound-Microwave multimodality imaging approach substantially improves the fidelity and accuracy of the reconstructed internal structures relative to previous studies that used radar-based microwave techniques to extract the internal structural information. An improvement in the sensitivity of the imaging algorithm to malignant tissue is also observed.
Biomedical imaging and sensing applications in many scenarios demand accurate surface estimation from a sparse set of noisy measurements. These measurements may arise from a variety of sensing modalities, including laser or electromagnetic samples of an object’s surface. We describe a state-of-the-art microwave imaging prototype that has sensors to acquire both microwave and laser measurements. The approach developed to translate sparse samples of the breast surface into an accurate estimate of the region of interest is detailed. To evaluate the efficacy of the method, laser and electromagnetic samples are acquired by sensors from three realistic breast models with varying sizes and shapes. A set of metrics is developed to assist with the investigation and demonstrate that the algorithm is able to accurately estimate the shape of a realistic breast phantom when only a sparse set of data are available. Moreover, the algorithm is robust to the presence of measurement noise, and is effective when applied to measurement scans of patients acquired with the prototype.
A second-generation monostatic radar system to measure microwave reflections from the human breast is presented and analyzed. The present system can measure the outline of the breast with an accuracy of ±1 mm and precisely place the microwave sensor in an adaptive matter such that microwaves are normally incident on the skin. Microwave reflections are measured between 10 MHz to 12 GHz with sensitivity of 65 to 75 dB below the input power and a total scan time of 30 min for 140 locations. The time domain reflections measured from a volunteer show fidelity above 0.98 for signals in a single scan. Finally, multiple scans of a breast phantoms demonstrate the consistency of the system in terms of recorded reflection, outline measurement, and image reconstruction.