BK21 FOUR Project, Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; jennynam5703@prostholabs.com (N.-E.N.)
Ms. Na-eun Nam
BK21 FOUR Project, Department of Prosthodontics, Yonsei University College of Dentistry, Yonsei-ro 50-1, Seodaemun-gu, Seoul 03722, Korea; jennynam5703@prostholabs.com (N.-E.N.)
Recent advances in three-dimensional (3D) printing have introduced new materials that can be utilized for dental restorations. Nonetheless, there are limited studies on the color stability of restorations using 3D-printed crowns and bridge resins. Herein, the color stability of conventional computer-aided design/computer-aided manufacturing (CAD/CAM) blocks and 3D-printing resins was evaluated and assessed for their degrees of discoloration based on material type, colorant types (grape juice, coffee, curry, and distilled water (control group)), and storage duration (2, 7, and 30 days) in the colorants. Water sorption, solubility, and scanning electron microscope (SEM) analyses were conducted. A three-way ANOVA analysis showed that all three factors significantly affected the color change of the materials. Notably, the discoloration (ΔE00) was significantly higher in all 3D printing resins (4.74–22.85 over the 30 days) than in CAD/CAM blocks (0.64–4.12 over the 30 days) following immersion in all colorants. 3D-printing resins showed color differences above the clinical limit (2.25) following storage for 7 days or longer in all experimental groups. Curry was the most prominent colorant, and discoloration increased in almost all groups as the storage duration increased. This study suggests that discoloration must be considered when using 3D printing resins for restorations.
Three-dimensional (3D) printing technology is highly regarded in the field of dentistry. Three-dimensional printed resin restorations must undergo a washing process to remove residual resin on the surface after they have been manufactured. However, the effect of the use of different washing solutions and washing times on the biocompatibility of the resulting resin restorations is unclear. Therefore, we prepared 3D-printed denture teeth and crown and bridge resin, and then washed them with two washing solutions (isopropyl alcohol and tripropylene glycol monomethyl ether) using different time points (3, 5, 10, 15, 30, 60, and 90 min). After this, the cell viability, cytotoxicity, and status of human gingival fibroblasts were evaluated using confocal laser scanning. We also analyzed the flexural strength, flexural modulus, and surface SEM imaging. Increasing the washing time increased the cell viability and decreased the cytotoxicity (p < 0.001). Confocal laser scanning showed distinct differences in the morphology and number of fibroblasts. Increasing the washing time did not significantly affect the flexural strength and surface, but the flexural modulus of the 90 min washing group was 1.01 ± 0.21 GPa (mean ± standard deviation), which was lower than that of all the other groups and decreased as the washing time increased. This study confirmed that the washing time affected the biocompatibility and mechanical properties of 3D printed dental resins.
This study analyzed the surface roughness and waviness, Vickers hardness (VHN), and color changes of six types of 3D printed resins and computer-aided design/computer-aided manufacturing (CAD/CAM) materials after artificial toothbrushing. The average surface roughness height (Ra) change of Formlabs denture teeth A2 resin (FMLB) was not significant between after artificial toothbrushing (0.17 ± 0.02 μm and 0.17 ± 0.05 μm, respectively; mean ± standard deviation). However, the Ra value increased significantly in all remaining groups. Regarding waviness, polymethylmethacrylate (PMMA) had the largest increases in average waviness height (Wa) and maximum surface waviness height (Wz) between, before (0.43 ± 0.23 μm and 0.08 ± 0.02 μm), and after (8.67 ± 4.03 μm, 1.30 ± 0.58 μm) toothbrushing. There were no significant changes in Wa for Formlabs denture teeth A2 resin (FMLB) and NextDent C&B (NXT). After artificial toothbrushing, the dispersed-filler composite (DFC) group had the largest color difference (ΔE, of 2.4 ± 0.9), and the remaining materials had smaller changes than the clinical acceptance threshold of ΔE = 2.25. The VHN of FMLB and NXT were 9.1 ± 0.4 and 15.5 ± 0.4, respectively, and were not affected by artificial toothbrushing. The flexural strengths of the 3D printed materials were 139.4 ± 40.5 MPa and 163.9 ± 14.0 MPa for FMLB and NXT, respectively, which were similar to those of the polycarbonate and PMMA groups (155.2 ± 23.6 MPa and 108.0 ± 8.1 MPa, respectively). This study found that the evaluated 3D printed materials had mechanical and optical properties comparable to those of CAD/CAM materials and were stable even after artificial toothbrushing and hydrothermal aging.
Reproduction of the exact interocclusal relationship using digital workflow is crucial for precise fabrication of accurate prostheses. Intraoral scanner is known to be valid for the measurement of quadrants, however, the role of missing area in the quadrant scan on the virtual interocclusal record (VIR) is uncertain. This study aimed to evaluate the accuracy of VIR in quadrant scans using an intraoral scanner (IOS) under four different edentulous conditions. Eight scans per group were obtained using a laboratory scanner and three IOSs (Trios3, CS3600, i500). Based on trueness and precision, Trios3 had the best results, followed by CS3600 and i500. The trueness and precision were affected by edentulous conditions. The three IOSs showed deviation in the posterior region during assessment of VIR for the missing area with posterior support. CS3600 and i500 showed deviation in the short-span edentulous area without support. In extended edentulous condition without support, Trios3 showed overclosure, while i500 showed an angular deviation. In some groups scanned with Trios3 and i500, the tilting effect was observed. Based on the edentulous condition and type of IOS used, local or general deviations in occlusion were seen. The accuracy of VIR was dependent on accurate scan data. Thus, registration of the occlusal relationship in an edentulous area with more than two missing teeth using IOSs may be clinically more inaccurate than that with a laboratory scanner.
Accuracy of implant position reproduction according to various types of scanners, implant placement depths, and tooth positions are unknown. The purpose of this study was to compare the accuracy of implant position reproduction for differences in the exposed length of the implant scan body according to scanner type and tooth position. Implants were placed at the positions of the lateral incisor, first premolar, and first molar in the study model at the bone level and submerged 1.5 mm, 3.0 mm, 4.5 mm, and 6.0 mm. The completed models were scanned with one type of tabletop scanner and three types of intraoral scanners (TRIOS 3, i500, and CS3600). A matching process was performed for all scan data to superimpose abutment library data on the scan body, and the root mean square errors were analyzed in three dimensions to evaluate the position reproducibility of the replaced abutment library. In the trueness analysis, the error increased rapidly for an implant placement depth of 4.5 mm, and was largest for a submersion of 6.0 mm. The precision analysis confirmed that the error increased for depths of at least 3.0 mm. The analysis by position identified that the accuracy was lowest for an implant placed at the position of the lateral incisor. These findings indicate that special care is required when making an impression of a deep implant with an optical scanner.
This study investigated the trueness of a digital implant impression according to the orientation of the implant scan body (ISB) and the scanning method. With the flat surface of the ISB facing either the buccal or proximal direction, the ISB was scanned using one tabletop scanner (T500) and three types of intraoral scanner (TRIOS 3, CS3600, and i500). The effects of differences in the scanning method and ISB orientation were assessed. Postalignment data were subsequently obtained with the abutments generated using a digital library, and superimposed with reference data using a best-fit algorithm, followed by root-mean-square error (RMSE) analysis. The RMSE was lower in the buccal groups (28.15 ± 8.87 μm, mean ± SD) than in the proximal groups (31.94 ± 8.95 μm, p = 0.031), and lower in the full-scan groups (27.92 ± 10.80 μm) than in the partial-scan groups (32.16 ± 6.35 μm, p = 0.016). When using the tabletop scanner, the trueness was higher when the ISB was connected buccally (14.34 ± 0.89 μm) than when it was connected proximally (29.35 ± 1.15 μm, p < 0.001). From the findings of this study it can be concluded that the operator should connect the ISB so that its flat surface faces the buccal direction, and attempt to scan all areas. Additionally, it is advantageous to connect an ISB buccally when using a tabletop scanner.