Ye-Chan Lee

Prof. Ye-Chan Lee

Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYe-Chan Lee
Ye-Chan Lee
JKJong-Eun Kim
Jong-Eun Kim
NNNa-eun Nam
Na-eun Nam
SSSeung-ho Shin
Seung-ho Shin
JLJung-Hwa Lim
Jung-Hwa Lim
JSJune-Sung Shim
June-Sung Shim
Reproduction of the exact interocclusal relationship using digital workflow is crucial for precise fabrication of accurate prostheses. Intraoral scanner is known to be valid for the measurement of quadrants, however, the role of missing area in the quadrant scan on the virtual interocclusal record (VIR) is uncertain. This study aimed to evaluate the accuracy of VIR in quadrant scans using an intraoral scanner (IOS) under four different edentulous conditions. Eight scans per group were obtained using a laboratory scanner and three IOSs (Trios3, CS3600, i500). Based on trueness and precision, Trios3 had the best results, followed by CS3600 and i500. The trueness and precision were affected by edentulous conditions. The three IOSs showed deviation in the posterior region during assessment of VIR for the missing area with posterior support. CS3600 and i500 showed deviation in the short-span edentulous area without support. In extended edentulous condition without support, Trios3 showed overclosure, while i500 showed an angular deviation. In some groups scanned with Trios3 and i500, the tilting effect was observed. Based on the edentulous condition and type of IOS used, local or general deviations in occlusion were seen. The accuracy of VIR was dependent on accurate scan data. Thus, registration of the occlusal relationship in an edentulous area with more than two missing teeth using IOSs may be clinically more inaccurate than that with a laboratory scanner.

21 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYe-Chan Lee
Ye-Chan Lee
Chunui LeeChunui Lee
Chunui Lee
JSJune-Sung Shim
June-Sung Shim
Ji-Man ParkJi-Man Park
Ji-Man Park
Yooseok ShinYooseok Shin
Yooseok Shin
KLKeun-Woo Lee
Keun-Woo Lee
Recently, digital technology has been used in dentistry to enhance accuracy and to reduce operative time. Due to advances in digital technology, the integration of individual mandibular motion into the mapping of the occlusal surface is being attempted. The Patient Specific Motion (PSM) is one such method. However, it is not clear whether the occlusal design that is adjusted using PSM could clinically show reduced occlusal error compared to conventional methods based on static occlusion. In this clinical comparative study including fifteen patients with a single posterior zirconia crown treatment, the occlusal surface after a clinical adjustment was compared to no adjustment (NA; design based on static occlusion), PSM (adjusted using PSM), and adjustment using a semi-adjustable articulator (SA) for the assessment of occlusal error. The root mean square (RMS; μm), average deviation value (±AVG; μm), and proportion inside the tolerance (in Tol; %) were calculated using the entire, subdivided occlusal surface and the out of tolerance area. Using a one-way ANOVA, the RMS and +AVG from the out of tolerance area showed a statistical difference between PSM (202.3 ± 39.8 for RMS, 173.1 ± 31.3 for +AVG) and NA (257.0 ± 73.9 for RMS, 210.9 ± 48.6 for +AVG). For the entire and subdivided occlusal surfaces, there were no significant differences. In the color-coded map analysis, PSM demonstrated a reduced occlusal error compared to NA. In conclusion, adjustment occlusal design using PSM is a simple and effective method for reducing occlusal errors that are difficult to identify in a current computer-aided design (CAD) workflow with static occlusion.