Margit Gfoehler

Prof. Dr. Margit Gfoehler

Institute of Engineering Design and Product Development, TU Wien, 1060 Vienna, Austria
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2007 in Human Movement Science
Verified
Journal Article
Closed access
CRChristian Redl
Christian Redl
MGMargit Gfoehler
Margit Gfoehler
Marcus PandyMarcus Pandy
Marcus Pandy

1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SFSimona Ferrante
Simona Ferrante
EAEmilia Ambrosini
Emilia Ambrosini
MGMarta Gandolla
Marta Gandolla
CCClaudia Casellato
Claudia Casellato
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
MUNDUS is an assistive framework for recovering direct interaction capability of severely motor impaired people based on arm reaching and hand functions. It aims at achieving personalization, modularity and maximization of the user’s direct involvement in assistive systems. To this, MUNDUS exploits any residual control of the end-user and can be adapted to the level of severity or to the progression of the disease allowing the user to voluntarily interact with the environment. MUNDUS target pathologies are high-level spinal cord injury (SCI) and neurodegenerative and genetic neuromuscular diseases, such as amyotrophic lateral sclerosis, Friedreich ataxia, and multiple sclerosis (MS). The system can be alternatively driven by residual voluntary muscular activation, head/eye motion, and brain signals. MUNDUS modularly combines an antigravity lightweight and non-cumbersome exoskeleton, closed-loop controlled Neuromuscular Electrical Stimulation for arm and hand motion, and potentially a motorized hand orthosis, for grasping interactive objects. The definition of the requirements and of the interaction tasks were designed by a focus group with experts and a questionnaire with 36 potential end-users. Five end-users (3 SCI and 2 MS) tested the system in the configuration suitable to their specific level of impairment. They performed two exemplary tasks: reaching different points in the working volume and drinking. Three experts evaluated over a 3-level score (from 0, unsuccessful, to 2, completely functional) the execution of each assisted sub-action. The functionality of all modules has been successfully demonstrated. User’s intention was detected with a 100% success. Averaging all subjects and tasks, the minimum evaluation score obtained was 1.13 ± 0.99 for the release of the handle during the drinking task, whilst all the other sub-actions achieved a mean value above 1.6. All users, but one, subjectively perceived the usefulness of the assistance and could easily control the system. Donning time ranged from 6 to 65 minutes, scaled on the configuration complexity. The MUNDUS platform provides functional assistance to daily life activities; the modules integration depends on the user’s need, the functionality of the system have been demonstrated for all the possible configurations, and preliminary assessment of usability and acceptance is promising.

9 February 2025 in Polymers
Verified
Journal Article
Open access
PDF file
JXJing Jing Xu
Jing Jing Xu
Michael HarasekMichael Harasek
Michael Harasek
MGMargit Gfoehler
Margit Gfoehler
The advent of 3D printing has revolutionized the fabrication of microfluidic devices, offering a compelling alternative to traditional soft lithography techniques. This review explores the potential of 3D printing, particularly photopolymerization techniques, fused deposition modeling, and material jetting, in advancing microfluidics. We analyze the advantages of 3D printing in terms of cost efficiency, geometric complexity, and material versatility while addressing key challenges such as material transparency and biocompatibility, which have represented the limiting factors for its widespread adoption. Recent developments in printing technologies and materials are highlighted, underscoring the progress in overcoming these barriers. Finally, we discuss future trends and opportunities, including advancements in printing resolution and speed, the development of new printable materials, process standardization, and the emergence of bioprinting for organ-on-a-chip applications. Sustainability and regulatory frameworks are also considered critical aspects shaping the future of 3D-printed microfluidics. By bridging the gap between traditional and emerging fabrication techniques, this review aims to illuminate the transformative potential of 3D printing in microfluidic device manufacturing.

1 April 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
Yi-Chung LinYi-Chung Lin
Yi-Chung Lin
MGMargit Gfoehler
Margit Gfoehler
Marcus PandyMarcus Pandy
Marcus Pandy

1 June 2000 in IEEE Transactions on Rehabilitation Engineering
Verified
Journal Article
Closed access
MGMargit Gfoehler
Margit Gfoehler
PLP. Lugner
P. Lugner
The goal of this paper was the development of an optimized stimulation pattern of leg muscles that would allow paraplegic subjects to perform the movement of pedaling and thereby to drive a tricycle by means of functional electrical stimulation (FES). To obtain maximum average power output with minimum muscle force, the start, duration and amplitude of the stimulation signal applied to the individual muscles had to be optimized depending on the pedaling frequency. For the basic theoretical investigations the rider-tricycle system was modeled as a rigid body system on which the muscle forces are applied as joint moments. The muscles gluteus maximus, rectus femoris, vastii, and hamstrings were stimulated and the passive forces of some other muscles were considered. The modeling and simulation approach was then used to produce maximum power pedaling and steady-state pedaling at 35 rpm. Hamstrings (41.9 %) and vastii (35.8 %) were the primary contributors to the optimization cost function of maximum power with minimum muscle loading. Based on these theoretical investigations an efficient stimulation pattern could be provided, taking into account the realistic possibilities of today's practical applications.

22 July 2014 in Robotica
Verified
Journal Article
Closed access
PDF file
EAEmilia Ambrosini
Emilia Ambrosini
SFSimona Ferrante
Simona Ferrante
MRMauro Rossini
Mauro Rossini
FMFranco Molteni
Franco Molteni
MGMargit Gfoehler
Margit Gfoehler
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SUMMARY: An assistive device for upper limb support was developed and evaluated in terms of usability, user satisfaction and motor performance on six end-users affected by neuro-motor disorders (three spinal cord injury; one multiple sclerosis; two Friedreich's ataxia). The system consisted of a lightweight 3-degrees-of-freedom robotic exoskeleton arm for weight relief, equipped with electromagnetic brakes. Users could autonomously control the brakes using a USB-button or residual electromyogram activations. The system functionally supported all of the potential users in performing reaching and drinking tasks. For three of them, time, smoothness, straightness and repeatability were also comparable to healthy subjects. An overall high level of usability (system usability score, median value of 90/100) and user satisfaction (Tele-healthcare Satisfaction Questionnaire - Wearable Technology, median value of 104/120) were obtained for all subjects.