Mauro Rossini

Dr. Mauro Rossini

Villa Beretta Rehabilitation Center - Valduce Hospital
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2001 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
JBJennifer Beck
Jennifer Beck
SGStewart B. Gottfried
Stewart B. Gottfried
PNPaolo Navalesi
Paolo Navalesi
YSYoanna Skrobik
Yoanna Skrobik
NCNorman Comtois
Norman Comtois
CSChrister Sinderby
Christer Sinderby
We compared crural diaphragm electrical activity (EAdi) with transdiaphragmatic pressure (Pdi) during varying levels of pressure support ventilation (PS) in 13 intubated patients. With changing PS, we found no evidence for changes in neuromechanical coupling of the diaphragm. From lowest to highest PS (2 cm H2O ± 4 to 20 cm H2O ± 7), tidal volume increased from 430 ml ± 180 to 527 ml ± 180 (p < 0.001). The inspiratory volume calculated during the period when EAdi increased to its peak did not change from 276 ± 147 to 277 ± 162 ml, p = 0.976. Respiratory rate decreased from 23.9 ( ± 7) to 21.3 ( ± 7) breaths/min (p = 0.015). EAdi and Pdi decreased proportionally by adding PS (r = 0.84 and r = 0.90, for mean and peak values, respectively). Mean and peak EAdi decreased (p < 0.001) by 33 ± 21% (mean ± SD) and 37 ± 23% with the addition of 10 cm H2O of PS, similar to the decrease in the mean and peak Pdi (p < 0.001) observed (34 ± 36 and 35 ± 23%). We also found that ventilator assist continued during the diaphragm deactivation period, a phenomenon that was further exaggerated at higher PS levels. We conclude that EAdi is a valid measurement of neural drive to the diaphragm in acute respiratory failure. Keywords: electromyography; mechanical ventilation; diaphragm; neuromechanical uncoupling

1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SFSimona Ferrante
Simona Ferrante
EAEmilia Ambrosini
Emilia Ambrosini
MGMarta Gandolla
Marta Gandolla
CCClaudia Casellato
Claudia Casellato
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
MUNDUS is an assistive framework for recovering direct interaction capability of severely motor impaired people based on arm reaching and hand functions. It aims at achieving personalization, modularity and maximization of the user’s direct involvement in assistive systems. To this, MUNDUS exploits any residual control of the end-user and can be adapted to the level of severity or to the progression of the disease allowing the user to voluntarily interact with the environment. MUNDUS target pathologies are high-level spinal cord injury (SCI) and neurodegenerative and genetic neuromuscular diseases, such as amyotrophic lateral sclerosis, Friedreich ataxia, and multiple sclerosis (MS). The system can be alternatively driven by residual voluntary muscular activation, head/eye motion, and brain signals. MUNDUS modularly combines an antigravity lightweight and non-cumbersome exoskeleton, closed-loop controlled Neuromuscular Electrical Stimulation for arm and hand motion, and potentially a motorized hand orthosis, for grasping interactive objects. The definition of the requirements and of the interaction tasks were designed by a focus group with experts and a questionnaire with 36 potential end-users. Five end-users (3 SCI and 2 MS) tested the system in the configuration suitable to their specific level of impairment. They performed two exemplary tasks: reaching different points in the working volume and drinking. Three experts evaluated over a 3-level score (from 0, unsuccessful, to 2, completely functional) the execution of each assisted sub-action. The functionality of all modules has been successfully demonstrated. User’s intention was detected with a 100% success. Averaging all subjects and tasks, the minimum evaluation score obtained was 1.13 ± 0.99 for the release of the handle during the drinking task, whilst all the other sub-actions achieved a mean value above 1.6. All users, but one, subjectively perceived the usefulness of the assistance and could easily control the system. Donning time ranged from 6 to 65 minutes, scaled on the configuration complexity. The MUNDUS platform provides functional assistance to daily life activities; the modules integration depends on the user’s need, the functionality of the system have been demonstrated for all the possible configurations, and preliminary assessment of usability and acceptance is promising.

3 March 2021 in Neurorehabilitation and Neural Repair
Verified
Journal Article
Closed access
PDF file
EAEmilia Ambrosini
Emilia Ambrosini
GGGiulio Gasperini
Giulio Gasperini
JZJohannes Zajc
Johannes Zajc
NINancy Immick
Nancy Immick
AAAndreas Augsten
Andreas Augsten
KKKarsten Krakow
Karsten Krakow
Robotic systems combined with Functional Electrical Stimulation (FES) showed promising results on upper-limb motor recovery after stroke, but adequately-sized randomized controlled trials (RCTs) are still missing. To evaluate whether arm training supported by RETRAINER, a passive exoskeleton integrated with electromyograph-triggered functional electrical stimulation, is superior to advanced conventional therapy (ACT) of equal intensity in the recovery of arm functions, dexterity, strength, activities of daily living, and quality of life after stroke. A single-blind RCT recruiting 72 patients was conducted. Patients, randomly allocated to 2 groups, were trained for 9 weeks, 3 times per week: the experimental group performed task-oriented exercises assisted by RETRAINER for 30 minutes plus ACT (60 minutes), whereas the control group performed only ACT (90 minutes). Patients were assessed before, soon after, and 1 month after the end of the intervention. Outcome measures were as follows: Action Research Arm Test (ARAT), Motricity Index, Motor Activity Log, Box and Blocks Test (BBT), Stroke Specific Quality of Life Scale (SSQoL), and Muscle Research Council. All outcomes but SSQoL significantly improved over time in both groups (P < .001); a significant interaction effect in favor of the experimental group was found for ARAT and BBT. ARAT showed a between-group change of 11.5 points (P = .010) at the end of the intervention, which increased to 13.6 points 1 month after. Patients considered RETRAINER moderately usable (System Usability Score of 61.5 ± 22.8). Hybrid robotic systems, allowing to perform personalized, intensive, and task-oriented training, with an enriched sensory feedback, was superior to ACT in improving arm functions and dexterity after stroke.

22 July 2014 in Robotica
Verified
Journal Article
Closed access
PDF file
EAEmilia Ambrosini
Emilia Ambrosini
SFSimona Ferrante
Simona Ferrante
MRMauro Rossini
Mauro Rossini
FMFranco Molteni
Franco Molteni
MGMargit Gfoehler
Margit Gfoehler
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
SUMMARY: An assistive device for upper limb support was developed and evaluated in terms of usability, user satisfaction and motor performance on six end-users affected by neuro-motor disorders (three spinal cord injury; one multiple sclerosis; two Friedreich's ataxia). The system consisted of a lightweight 3-degrees-of-freedom robotic exoskeleton arm for weight relief, equipped with electromagnetic brakes. Users could autonomously control the brakes using a USB-button or residual electromyogram activations. The system functionally supported all of the potential users in performing reaching and drinking tasks. For three of them, time, smoothness, straightness and repeatability were also comparable to healthy subjects. An overall high level of usability (system usability score, median value of 90/100) and user satisfaction (Tele-healthcare Satisfaction Questionnaire - Wearable Technology, median value of 104/120) were obtained for all subjects.

5 June 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
EAEmilia Ambrosini
Emilia Ambrosini
JZJohannes Zajc
Johannes Zajc
SFSimona Ferrante
Simona Ferrante
Giancarlo FerrignoGiancarlo Ferrigno
Giancarlo Ferrigno
SGStefano Dalla Gasperina
Stefano Dalla Gasperina
Alessandra PedrocchiAlessandra Pedrocchi
Alessandra Pedrocchi
Objective: To develop and evaluate a hybrid robotic system for arm recovery after stroke, combining EMG-triggered Functional Electrical Stimulation (FES) with a passive exoskeleton for upper limb suspension. Methods: The system was used in a structured exercise program resembling activities of daily life. Exercises execution was continuously controlled using angle sensor data and Radio-Frequency IDentification (RFID) technology. The training program consisted of 27 sessions lasting 30 minutes each. Seven post-acute stroke patients were recruited from two clinical sites. The efficacy of the system was evaluated in terms of Action Research Arm Test, Motricity Index, Motor Activity Log, and Box & Blocks tests. Furthermore, kinematics-based and EMG-based outcome measures were derived directly from data collected during training sessions. Results: All patients showed an improvement of motor functions at the end of the training program. After training, the exercises were in most cases executed faster, smoother and with an increased range of motion. Subjects were able to trigger FES, but in some cases, they did not maintain the voluntary effort during task execution. All subjects but one considered the system usable. Conclusion: The preliminary results showed that the system can be used in a clinical environment with positive effects on arm functional recovery. However, only the final results of the currently ongoing clinical trial will unveil the system full potential. Significance: The presented hybrid robotic system is highly customizable, allows to monitor the daily performance, requires low supervision of the therapist and might have the potential to enhance arm recovery after stroke.

1 July 2017
Verified
Conference Paper
Open access
EAEmilia Ambrosini
Emilia Ambrosini
SFS. Ferrante
S. Ferrante
JZJ. Zajc
J. Zajc
MBMaria Bulgheroni
Maria Bulgheroni
WBWalter Baccinelli
Walter Baccinelli
APA. Pedrocchi
A. Pedrocchi
The combined use of Functional Electrical Stimulation (FES) and robotic technologies is advocated to improve rehabilitation outcomes after stroke. This work describes an arm rehabilitation system developed within the European project RETRAINER. The system consists of a passive 4-degrees-of-freedom exoskeleton equipped with springs to provide gravity compensation and electromagnetic brakes to hold target positions. FES is integrated in the system to provide additional support to the most impaired muscles. FES is triggered based on the volitional EMG signal of the same stimulated muscle; in order to encourage the active involvement of the patient the volitional EMG is also monitored throughout the task execution and based on it a happy or sad emoji is visualized at the end of each task. The control interface control of the system provides a GUI and multiple software tools to organize rehabilitation exercises and monitor rehabilitation progress. The functionality and the usability of the system was evaluated on four stroke patients. All patients were able to use the system and judged positively its wearability and the provided support. They were able to trigger the stimulation based on their residual muscle activity and provided different levels of active involvement in the exercise, in agreement with their level of impairment. A randomized controlled trial aimed at evaluating the effectiveness of the RETRAINER system to improve arm function after stroke is currently ongoing.