In recent years, research into the field of materials for flexible sensors and fabrication techniques directed towards wearable devices has helped to raise awareness of the need for new sensors with healthcare applicability. Our goal was to create a wearable flexible pressure sensor that could be integrated into a clinically approved blood pressure monitoring device. The sensor is built from a microfluidic channel encapsulated between two polymer layers, one layer being covered by metal transducers and the other being a flexible membrane containing the microfluidic channel, which also acts as a sealant for the structure. The applied external pressure deforms the channel, causing changes in resistance to the microfluidic layer. Electrical characterization has been performed in 5 different configurations, using alternating current (AC) and (DC) direct current measurements. The AC measurements for the fabricated pressure sensor resulted in impedance values at tens of hundreds of kOhm. Our sensor proved to have a high sensitivity for pressure values between 0 and 150 mm Hg, being subjected to repeatable external forces. The novelty presented in our work consists in the unique technological flow for the fabrication of the flexible wearable pressure sensor. The proposed miniaturized pressure sensor will ensure flexibility, low production cost and ease of use. It is made of very sensitive microfluidic elements and biocompatible materials and can be integrated into a wearable cuffless device for continuous blood pressure monitoring.
Green chemistry is a pharmaceutical industry tool, which, when implemented correctly, can lead to a minimization in resource consumption and waste. An aqueous extract of Salix alba L. was employed for the efficient and rapid synthesis of silver/gold particle nanostructures via an inexpensive, nontoxic and eco-friendly procedure. The nanoparticles were physicochemically characterized using ultraviolet–visible spectroscopy (UV–Vis), Fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), X-ray diffraction (XRD) and scanning electron microscopy (SEM), with the best stability of up to one year in the solution obtained for silver nanoparticles without any chemical additives. A comparison of the antimicrobial effect of silver/gold nanoparticles and their formulations (hydrogels, ointments, aqueous solutions) showed that both metallic nanoparticles have antibacterial and antibiofilm effects, with silver-based hydrogels having particularly high antibiofilm efficiency. The highest antibacterial and antibiofilm efficacies were obtained against Pseudomonas aeruginosa when using silver nanoparticle hydrogels, with antibiofilm efficacies of over 75% registered. The hydrogels incorporating green nanoparticles displayed a 200% increased bacterial efficiency when compared to the controls and their components. All silver nanoparticle formulations were ecologically obtained by “green synthesis” and were shown to have an antimicrobial effect or potential as keratinocyte-acting pharmaceutical substances for ameliorating infectious psoriasis wounds.
Developing a sensing layer with high electroactive properties is an important aspect for proper functionality of a wearable sensor. The polymeric nanocomposite material obtained by a simple electropolymerization on gold interdigitated electrodes (IDEs) can be optimized to have suitable conductive properties to be used with direct current (DC) measurements. A new layer based on polyaniline:poly(4-styrenesulfonate) (PANI:PSS)/single-walled carbon nanotubes (SWCNT)/ferrocene (Fc) was electrosynthesized and deposed on interdigital transducers (IDT) and was characterized in detail using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy (SEM), Raman spectroscopy, X-ray photoemission spectroscopy (XPS), and X-ray diffraction (XRD). The sensor characteristics of the material towards carbon monoxide (CO) in the concentration range of 10–300 ppm were examined, showing a minimal relative humidity interference of only 1% and an increase of sensitivity with the increase of CO concentration. Humidity interference could be controlled by the number of CV cycles when a compact layer was formed and the addition of Fc played an important role in the decrease of humidity. The results for CO detection can be substantially improved by optimizing the number of deposition cycles and enhancing the Fc concentration. The material was developed for selective detection of CO in real environmental conditions and shows good potential for use in a wearable sensor.
With the global market value of sensors on the rise, this paper focuses on the fabrication and testing of a proof-of-concept piezoelectric energy harvester which is able to harvest mechanical energy from the ambient environment and convert it into electrical energy in order to power wireless sensor networks. We focused on obtaining a new device structure based on a comb-type array of piezoelectric MEMS cantilevers (2 × 10) for a resonant frequency in the environmental application domain (a few hundred Hz) and a chip area of only 1 cm2. The configuration of the lead-free piezoelectric cantilever consists of a Si substrate, a pair of Ti-Pt electrodes and a sputtered piezoelectric layer of 12% Sc-doped AlN with a thickness of 1000 nm, a dielectric constant of ~13 and e31,f = 1.3 C/m2. At a resonant frequency of 465.2 Hz and an acceleration of 1 g, the maximum value for the collected power was 2.53 µW for an optimal load resistance of 1 MΩ resulting in a power density of 60.2 nW/mm3 for the unpacked device, without taking into account the vibration volume. By increasing the excitation acceleration to 2 g RMS and using LTC3588-1 for the power circuitry we were able to obtain a stabilized output voltage of 1.8 V.
This study investigates the antioxidant, antimicrobial, and antitumor activities of Taraxacum officinale (Dandelion) and Artemisia annua (Sweet Wormwood) extracts, along with their role in the green synthesis of gold (AuNPs) and silver nanoparticles (AgNPs). Bioreduction was achieved using aqueous and ethanolic extracts (100 mg/mL), enabling solvent-dependent comparisons. Nanoparticles were characterized using ultraviolet–visible spectroscopy (UV–Vis), fluorescence spectroscopy, scanning electron microscopy (SEM), dynamic light scattering (DLS), high-resolution transmission electron microscopy (HRTEM), and zeta potential analysis. Each technique revealed complementary aspects of nanoparticle morphology, size, and stability, with UV–Vis indicating aggregation states and DLS confirming solvent-related size variation even at 3–5% ethanol. Gold nanoparticles synthesized from Dandelion showed strong antibacterial activity against Staphylococcus aureus, while silver nanoparticles from both plants were effective against Escherichia coli. Cytotoxicity assays indicated that silver nanoparticles obtained from ethanolic Dandelion extract containing 3% ethanol in aqueous solution (AgNPsEETOH3%-D) significantly reduced LoVo (p = 4.58 × 10−3) and MDA-MB-231 (p = 7.20 × 10−5) cell viability, with high selectivity indices (SI), suggesting low toxicity toward normal cells. Gold nanoparticles synthesized from aqueous Dandelion extract (AuNPsEaq-D) also showed favorable SI values (2.16 for LoVo and 8.41 for MDA-MB-231). Although some formulations demonstrated lower selectivity (SI < 1.5), the findings support the therapeutic potential of these biogenic nanoparticles. Further in vivo studies and pharmacokinetic evaluations are required to validate their clinical applicability.
Sensor systems for monitoring indoor air quality are vital for the precise quantification of the mechanisms which lead to the deterioration of human health, with a typical person spending an average of 20 h a day in an enclosed space. Thus, a series of layered chemoresistive sensors, obtained by the facile electrodeposition of carbon nanomaterial-enhanced PANI composites, have been tested for the selective detection of two core indoor pollutants: ammonia and nitrogen dioxide. The sensors were tested with respect to sensitivity and selectivity to the target gasses, with performance being assessed based on response linearity and repeatability at room temperature. Of the tested sensors, two have been identified as having an adequate performance on ammonia, with sensitivities of up to 96.99% and resolutions of up to 0.85 ppm being observed, while on nitrogen dioxide, despite the successful sensor having a lower sensitivity, 10.71%, it has shown high resolution, 1.25 ppm, and linearity over a large concentration domain. These high performances highlight the viability of multi-layers chemosensors based on the electrodeposition of nanomaterial-enhanced conductive polymers for the detection of pollutant gasses, with finetuning of the detection layer allowing the accurate monitoring of a wide range of gasses.